My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085874_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
7500
>
2600 - Land Use Program
>
SR0085874_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:58 AM
Creation date
10/12/2022 3:43:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0085874
PE
2602
FACILITY_ID
FA0007821
FACILITY_NAME
ARCO & AM/PM
STREET_NUMBER
7500
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
25015018
ENTERED_DATE
10/5/2022 12:00:00 AM
SITE_LOCATION
7500 W ELEVENTH ST
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
View images
View plain text
Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1, Satisfactor;r perc. <br /> 9/13/2022 3.35 5.68 4 hr. <br /> rate <br /> Shallow Test <br /> Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 minutes per <br /> inch. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 5.0 and 30.0 min/in requires an <br /> 8-foot separation between the bottom of dispersal system and ground water, or mitigation by system design <br /> or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a septic system in accordance with the <br /> requirements of the San Joaquin County Environmental Health Department. This <br /> percolation test is considered representative of soils within a 100-foot radius of the test <br /> location. <br /> Because of the percolation rate between 5.0 and 30.0 min/in encountered in the test <br /> hole, the San Joaquin County Environmental Health Department will require an 8-foot <br /> separation from the bottom of the dispersal system to ground water, unless mitigated by <br /> system design or enhancement. Given the depth to water of 15 to 16 feet measured by <br /> Quantum Geotechnical, no modification to a standard, shallow system should be <br /> necessary to fulfill this requirement. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines or a filter bed should follow the San <br /> Joaquin County On-Site Wastewater Treatment Systems Standards (2017) where <br /> applicable. Additional considerations are discussed in the Nitrate Loading Study. <br /> LOGE 2240 Page 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).