EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1605
>
1600 - Food Program
>
PR0540887
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2023 2:36:15 PM
Creation date
10/12/2022 4:02:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0540887
PE
1632
FACILITY_ID
FA0023385
FACILITY_NAME
ASPIRE ARTS & SCIENCES ACADEMY
STREET_NUMBER
1605
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1605 E MARCH LN
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KEY NOTE SCHEDULE <br /> 10 (E)VAV BOX/ RE-HEAT COIL TO REMAIN. r CI ■0z 1A INSTALL (N)VAV BOX TO SERVE ENTRY. THERMOSTAT TO BEStu <br /> LOCATED AT FIRST FLOOR LEVEL. <br /> 1 B $P.O.C. CONNECT(N) HWS AND HWR TO (E) HWS AND WWR n C Y <br /> AND EXTEND TO (N)VAV BOX. / <br /> C/) <br /> 1C PROVIDE 3-WAY CONTROL VALVE. REFER TO DETAIL 5/M8.10.-$1Architecture <br /> 02 P.O.C. CONNECT(N)SUPPLY DUCT TO (E) SUPPLY DUCT AND <br /> LU EXTEND AS INDICATED. PROVIDE TRANSITION AS REQUIRED TO <br /> MAKE CONNECTION. <br /> LU 03 INSTALL (N)THERMOSTAT IN LOCATION SHOWN, MOUNT WITH TOP 110 LINDEN STREET OAKLAND,CA 1 94607 <br /> m <br /> 5 10.836.6594 I stud iobondy.com <br /> Q <br /> 40 PROVIDE 24"x12"ACOUSTICALLY LINED "Z" DUCT TO ALLOW AIR <br /> J BACK TO CENTRAL PLENUM RETURN INLET <br /> a_ <br /> Q 05 CAP (E)SUPPLY DUCT OFF (E)VAV DISCHARGE PLENUM. <br /> 0 <br /> w <br /> ASPIRE <br /> z <br /> Q STOCKTON <br /> U <br /> ELEMENTARY <br /> w <br /> 0 SCHOOL <br /> of <br /> w PROJECT NO:: 2013.00 <br /> 0 1605 EAST MARCH LANE I STOCKTON,CA 1 95210 <br /> P:000.000.0000 I F:000.000.0000 <br /> LU <br /> LL <br /> LU <br /> C/) STRUCTURAL ENGINEER <br /> 0 PEOPLES ASSOCIATE <br /> cn STRUCTURAL ENGINEERS <br /> 1150 CAMPBELL AVE, SAN JOSE, CA 95126 <br /> 0 CONTACT: MICHAEL DEIGERT <br /> 408.957.9220 x 108 P <br /> E-MAIL: mdeigert@pase.com <br /> F- <br /> Q <br /> LU CIVIL ENGINEER <br /> SIEGFRIED <br /> 3428 BROOKSIDE ROAD <br /> Q STOCKTON, CA 95825 <br /> z CONTACT: ADAM MERRIL <br /> 209.943.2021 P <br /> Q E-MAIL: amerrill@siegfriedeng.com <br /> z <br /> uj <br /> z 1 2 3 4 5 6 7 8 9 10 11 LANDSCAPE ARCHITECTSIEGFRIED <br /> 0 3428 BROOKSIDE ROAD <br /> z I I I I I I I I I I I STOCKTON, CA 95825 <br /> Q CONTACT: ROBERT NORBUTAS <br /> 209.943.2021 P <br /> 3: ' ' ' ' ' ' ' ' ' ' ' E-MAIL: bnorbutas@siegfriedeng.com <br /> Q <br /> J <br /> I I I I I I I I I I <br /> MECHANICAL <br /> (D MODERN AIR MECHANICAL <br /> 2200 COOPER AVENUE <br /> � I I I I I I I I I I MERGED, CA 95344 <br /> 0 CONTACT: MARK LEITING <br /> U 209.722.0076 P <br /> C/) i i E-MAIL:mleiting@modernair.biz <br /> uj <br /> Q ELECTRICAL <br /> NORTH STATE ELECTRICAL CONTRACTORS <br /> 0 I I I I I I I I <br /> LU SCOTTJACOBS <br /> 11101 WHITE ROCK ROAD <br /> z I I I I I 1 10"0 EXH. DN 1 RANCHO CORDOVA, CA 95670 <br /> CONTACT: SCOTT JACOBS <br /> 916.462.0817 P <br /> A -------------- _ <br /> m ' • tt�� •� E-MAIL. sco orthstate-eci.com n <br /> CS-1 CS-1 <br /> 280 CFM 280 CFM 10"0 EXH DUCT THRU ROOF WITH <br /> L I CLASSROOM 10"0 1 10,10 (E)10"0 FLASHING &WEATHER CAP I I PLUMBING <br /> CLASSROOM <br /> U CS-1 I PRO-TEC PLUMBING <br /> 211 CLASSROOM CS-1 CS-1 CS-1 CS-1 CS-1 CONTA T: ED BOSQUE <br /> LU <br /> L 385 CFM CS(E) 212 CS(E) 245 CFM 245 CFM , 245 CFM 470 CFM 216 470 CFM <br /> 0 12"0 235 CFM CS(E) 285 CFM CS(E) 10"0 10"0 10"0 12"0 12"0 916.337.2138 P <br /> � 12"0 235 CFM 285 CFM 10"0 CS-1 @p p 9@ <br /> 0- 12"QJ <br /> � CS-1 (E)10"0 (E)10"0 , 245 CFM E-MAIL: e rotec um in net <br /> 10"0 10"0 (E)10"0 10"0 - <br /> 385 CFM CR-1 1 b 10'0 <br /> 1120 CFM NII (E)10"0 E 10 (E)10 0 0 (E)VAV 2-3 10"0 <br /> � 12"0 ......... 22"x22" <br /> (E)VAV 2-7 CS-1 10"0 _ 0110 -, � F- V-11CS-1 <br /> 2 <br /> 280 CFM HMO1_JCLASSROOM O — 18 0 CR-1 <br /> o CLASSROOM O \\\ 10"0 (E)VAV 2-6 CS-1 (E)VAV 2-5 (E)VAV 2-4 '' o ;;: (E)VAV 2-2 <br /> z <br /> Q 0 ' 280 CFM o 245 C M 214 � �: ::: 1880 CFM CS-1 <br /> L 210 10"0 0 1 O ` w 10" — O 22"x46" 470 CFM <br /> Q 3 0 <br /> \ CS(E) CSCE) CS(E) CS(E) / DA CS-1 CS-1 CS-1 12 0 <br /> 235 CFM I 285 CFM _/1 IIrR-A10"0 0 245 CFM 245 CFM ` 2A CS-1 470 CFM <br /> 0 `' I ' � 16"0 — — � 235 CFM 285 CFM I0 � 10"0 10"0 \ 2A 245 CFM 12"0 12"0 <br /> a_ CS-1 CS-1 245 CFM (E)VAV-2-6 CR(E) ��� I DA CLASSROOM CR(E) CR-1 ,' DA CLASSROOM 18 0 6' 10"0 \ <br /> LU f10"0 I 940 CFM _ �)16"0_ 1140 CFM 980 CFM � j (E)VAV 2- <br /> Y 385 CFM 385 CFM I 1 <br /> 12'0 12"0 10" 213 (E)16"0 215 <br /> / _ 22"x22" I <br /> .00 <br /> 3 T 3 3 - - // <br /> 10"0 2 5I O C -1 CR-1 18"0 (R)VAV 2-200 _ uN <br /> 1 I CR-1 03 <br /> Z: 3851CFM 1540 CFM 385 FM 980 CFM CS-1 <br /> .......... <br /> DA HALLWAY STAIR 4 <br /> CR-1 18 I�?i ,`�v���1 'QJ 46"x22" i i I` 12'0 I 22"x22" F71 <br /> z 1540 CFM O O !)TLE] <br /> (E)VAV-2-15 STAIR #1 io <br /> L,� �. �"('��, �� , y+`' 218 385 CFM STR 4 <br /> 46"x22" 10 TEACHERS' STR 1 BUILDING PERMIT <br /> ' CS-1 ` ' 12"0 —12"0 18"0 i v 1 12"0 12 0 1 <br /> `7' BREAK ROOM 385 CFM STORAGE 12 0 I <br /> ^/ _ 12"0 24"0 <br /> = - - — - --O T o LV <br /> 1 CS-1 208 -- -- - - -- - - - - - - - - 226 1B - - - - L ��-- - - - <br /> 0 OFFICE I 245 CFM CFM <br /> RESTROOM (E)VAV-2-18 <br /> 209 ' 00 10"0 8„0 (E) I.T. 1 (� 30 0 0M � i __\�_°r° 222 O STAIR #2I (E)VAV 2-14 PERMIT SUBMITTAL 11.05.2021 <br /> } 00 R-1 225 v 0f E MECH STR 2 O I:;;:;:::;: 12"0 <br /> �I CR-1 -J 180 CFM CE-2 I \ REST <br /> ( ) a I 4 5 CFM E VAV 2-1 2 4 5 CFM BUILDING PLAN CHECK 10.28.2021 <br /> CS-1 1 490 CFM I CS-1 22"x22" I 1 220 1 ( ) COMMENTS RESPONSE <br /> 280 CFM CR-1 I `\ 22"x22" I 150 CFM 01� M 1 2 12"0 <br /> ::::,::.. 12"0 <br /> 0 10 0 280 CFM I 1 CR-1 8"0 —MEETING (E)WALL CR-1 00 00 0 / <br /> RESTROOM o a 14"0 22'� 12"Q) '� B PROJECT DEVELOPMENT 10.28.2021 <br /> 22"x22" �❑ 150 CFM FAN COIL CS- 6'0 CLASSROOM <br /> ' 6"0 , ' 3000 CFM � �': :. 2 � <br /> 3 T 22"X22" J 207 12"x10"EA DN (E) ELEC RICAL 223 90 C • I l 2A 22"x46" N <br /> a � �: 0 � 217 � C PROJECT REVISIONS 12.17.2021 <br /> J 12 1 22 6" 1 r 1 i 2 12"0 <br /> Q CS-1 10"0 � 18"0 14"0— ��"0 CE-2 -�/ .00 <br /> STAIR #3 32 10,10 M CS-1 - CS-2� 100 CFM T CS-1 <br /> TR 3 I 10"0 ' 320 CFM N CS-1 HALLWAY 90 CFM1 1 455 CFM I I <br /> 14 0 � CS- 6"0 CS-1 <br /> M w 10 0 6"0 CS-1CR-1 12"0 <br /> 10"0 CR-1 EF 62 620 CFM 219 <br /> 620 CFM 0 60 C M 1820 CFM 455 CFM <br /> 14"0 <br /> -� 1180 CFM , 1 6 1 46"x22" 12 0 <br /> LU 0 22"0 2A 22"x22" _ <br /> — — — — — -- — — — — — — — — -- — — r — — w — (E-)VAV-24a-- — — — — <br /> z 03 T T T - — - 1 20"0 1 - - WS-1 WS-1 i <br /> _ _14"00 1 0 1780 CFM 1780 CFM <br /> LU CR-1 2A 3 36"x12" 36"x12" <br /> = 1860 CFM CS-1 2A DA \ 2A ' T03 (E)EXH UP T 3 18� T i HI WALL HI WALL i <br /> CS-1 46"x22" ' 295 CFM R_1 12"0 EXH UP I CR-1 <br /> = o CS-1 18"0 CS-1 i <br /> 310 CFM I 10"0 16'0 15 CFM — 1220 CFM � MAIN <br /> U_ 10"0 18"0 �� 295 CFM 345 CFM ` CR-1 ' <br /> r — 10"0 4 x22" 22"x22" / __ ENTRY <br /> a z CS-1 1 �� �� 10"0 CR-1 750 CFM <br /> n Q 310 CFM �� ; " I \ i �� I , 1380 CFM 14 0 1k <br /> 2 22"x22" 100 <br /> 10"0 y I �,� `,, ' I 46"x22" R I I <br /> CS-1 I ' 12"0 12"0 <br /> o I CS-1 CS-1 CS- CS-1 CS-1 <br /> Q = o I 1 385 CFM i 385 CFM 305 CFM 305 CFM 1_ ' 375 CFM 375 CFM <br /> c� - 12"0 10"0 \ <br /> _ o \ 12"0 10"0 LA6�0 (E)VAV 2-12 12"0 12"0 <br /> (E)VAV 2-11 l9 10 <br /> E VAV2,--q. 10 10"0 10" <br /> 0 0 (E)VAV-2-19A 'o2 2 <br /> - - - - - - �- - - - - - - - - -- - - - - - <br /> - -- O <br /> ® 10, <br /> (E)VAV 2-10 10"0 �- -� ' 2 2 CS-1 i i i 1 <br /> CD J ''�'�'�•' _J 1 2 2 � 345 CFM CO ROOM <br /> Q CS-1 10 CS-1 16,0 510 14"0 8 0 O �0 10 0 201 <br /> rn 310 CFM 310 CFM O � � <br /> 0 .01 <br /> z 10"0 10"0 16"0 O 2 <br /> 0 <br /> 0 O 10 I I I I <br /> i <br /> LU 100 <br /> I I <br /> � CLASSROOM <br /> CS-1 CS-1 CS-1 CS-1 CS-11 MECHANICAL <br /> � � CS-1 CS-1 385 CFM 305 CFM 305 CFM 345 CFM 345 CFM QROFESS/pv <br /> ai U CS-1 CS-1 295 CFM 205 295 CFM 12"0 10"0 10"0 10"0 10"0 1 �� EN ql <br /> LU 310 CFM CS-1 �� F <br /> 310 CFM 10"0 10"0 I � .01 <br /> 1 CLASSROOM 10"0 CLASSROOM 385 CFM CLASSROOM <br /> o _ 10"0 7"0 EXH DUCT THRU ROOF WITH CLASSROOM <br /> 206 ��— 204 12"0 203 3 9 SECOND FLOOR <br /> N v FLASHING &WEATHER CAP !�j 1� 2 <br /> F <br /> PLAN <br /> 0 0 7"0 EXH DN M O D E R NR A II R 9TF OF <br /> �FCHAN�OP �P <br /> MECHANICAL <br /> ACTORS <br /> V) z I I I I 1 2200 Cooper Ave.P.O.Box 3017 Merced,CA 95344 <br /> U <br /> Q m <br /> Consulting Mechanical Engineers <br /> Q U NORTH 0 �]� 1400 Lone Palm Ave,Suite A <br /> Modesto,(/� <br /> 1 MECHANICAL — SECOND FLOOR PLAN TeI209.572.399 1 Fax:209.236.1579 M2 . 12 <br /> N o o www.nexusengineering.net <br /> CM2.12 SCALE: 1/8" = V-0" ° 0 .04° ? QU HVAC.Plumbing/Piping.Fire Sprinklers <br /> oProcess/Plant Engineering.Refrigeration <br /> N <br /> N <br /> O <br /> N <br />