PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />November 22, 2022 <br /> Facility Address: <br /> 800 E Kettleman Ln, Lodi <br /> Facility Name: <br /> ARCO 07049 <br />File Review <br /> 122 □ V □ R □ COS Failure to implement corrections and submit written response within 30 days of receiving the reportCCR 2712(f) <br />On Site Records <br /> 201 □ V □ R □ COS Failure to maintain UST records to enable the UPA to determine whether the UST is in complianceHSC 25293 <br /> 202 □ V □ R □ COS Failure to retain a paper or electronic copy of the permit to operate at the facilityCCR 2712(i) <br /> 203 □ V □ R □ COS Failure to maintain monitoring records for 36 months and maintenance records for 60 monthsCCR 2712(b)(1-2) <br /> 204 □ V □ R □ COS Failure to maintain records of repairs, lining, and upgrades on site, for the life of the USTCCR 2712(b)(6) <br /> 205 □ V □ R □ COS Failure to submit and have current UST Monitoring Plan readily accessible at the facilityCCR 2712(i) <br /> 206 □ V □ R □ COS Failure to submit and have a current UST Response Plan readily available on siteCCR 2712(i), 2634(e) <br /> 207 □ V □ R □ COS Failure to maintain designated operator inspection reports and all attachments on site for 36 monthsCCR 2716(f) <br /> 208 □ V □ R □ COS Failure to comply with the designated operator inspection requirementsCCR 2716(a-e) <br /> 209 □ V □ R □ COS Failure to maintain a copy of the "Facility Employee Training Certificate" on-siteCCR 2715(c)(3), 2715(c) <br />(4) <br /> 210 □ V □ R □ COS Failure to provide initial training, train every 12 months, and have a trained employee presentCCR 2715(c) <br /> 211 □ V □ R □ COS Failure to have or implement a training program approved by the UPA, at an unstaffed facilityCCR 2715(c)(2) <br /> 212 □ V □ R □ COS Failure to record any unauthorized release from primary containmentCCR 2651; HSC 25294 <br /> 213 □ V □ R □ COS Failure to notify and submit report of reportable unauthorized release or record releaseCCR 2650(e), 2652 <br /> 214 □ V □ R □ COS Failure to comply with UST operating permit conditionsCCR 2712 <br /> 215 □ V □ R □ COS Designated operator, service tech, or installer did not possess current certificationsCCR 2715 <br /> 216 □ V □ R □ COS Failure to meet exclusion requirements for unburied fuel piping at a marinaHSC 25281.5(b)(2) <br /> 217 □ V □ R □ COS Failure to meet exemption requirements for emergency generator unburied fuel pipingHSC 25281.5(b)(3) <br />UST System Observations <br /> 301 □ V □ R □ COS Failure to operate UST system to prevent unauthorized releases including leaks, spills and overfillsHSC 25292.1(a) <br /> 302 □ V □ R □ COS Leak detection equipment not installed/maintained/located to detect leaks at earliest opportunityCCR 2630(d), 2641(a) <br /> 303 □ V □ R □ COS Failure to maintain piping to allow liquid to flow into sump (i.e. failure to remove test boots)CCR 2630(d), 2641(a) <br /> 304 ■ V □ R □ COS Failure to construct, operate, and maintain primary containment as product-tightCCR 2631(a); HSC <br />25290.1(c) <br /> 305 □ V □ R □ COS Failed to maintain secondary containment (e.g. failure of secondary containment testing)HSC 25290.1, 25290.2, <br />25291 <br /> 306 □ V □ R □ COS Failure to remove, analyze, and properly dispose of water in secondary containment (pre-Jul 2003)HSC 25291(e) <br /> 307 ■ V ■ R □ COS Failure to keep water out of the secondary containment system (post-Jul 2003)HSC 25290.1(c3), <br />25290.2(c3) <br /> 308 □ V □ R □ COS Failure of the leak detection equipment to have an audible and visual alarmCCR 2632(c), 2634(d), <br />2636(f) <br /> 309 □ V □ R □ COS Failure to have continuous monitoring that activates audible-visual alarm or stops flow at dispenserCCR 2666(b)(2), 2636(f) <br />(1) <br /> 310 □ V □ R □ COS Failure to meet monitoring requirements in lieu of being tightness tested every 12 monthsCCR 2636(f)(4) <br /> 311 □ V □ R □ COS Monitoring system incapable of detecting leak into secondary containment (pre-Jul 2003)HSC 2636(a)(1), <br />25291(b) <br /> 312 □ V □ R □ COS Monitoring system incapable of detecting entry into secondary containment (Jul 2003-Jun 2004)HSC 25290.2(d) <br />FA0003633 PR0231349 SC001 11/22/2022 <br />EHD 23-01 Rev. 12/06/2021 Underground Storage Tank Program OIRPage 2 of 5 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.