Laserfiche WebLink
(4) the effectiveness of additional treatment, design, or monitoring <br />techniques. <br />Nor- Authority cited: Sections 208, 25150 and 25159, Health and Safety Code. <br />Reference: Sections 25150, 25159 and 25159.5, Health and Safety Code; 40 CFR <br />Section 270.20. <br />His-roRY <br />New section filed 5-24-91; operative 7-1-91 (Register 91, No. 22). <br />§ 66270.21. Specific Part B Information Requirements for <br />Landfills. <br />Except as otherwise provided in section 66264.1, owners and opera- <br />tors of facilities that dispose of hazardous waste in landfills shall provide <br />the following additional information: <br />(a) a list of the hazardous wastes placed or to be placed in each landfill <br />or landfill cell; <br />(b) detailed plans and an engineering report describing how the landfill <br />is or will be designed, constructed, operated and maintained to comply <br />with the requirements of section 66264.301. This submission shall ad- <br />dress the following items as specified in section 66264.301: <br />(1) the liner system and leachate collection and removal system (ex- <br />cept for an existing portion of a landfill). If an exemption from the re- <br />quirements for a liner and a leachate collection and removal system is <br />sought as provided by section 66264.301(b), submit detailed plans and <br />engineering and hvdrogeoiogic reports, as appropriate, describing alter- <br />nate design and operating practices that will, in conjunction with location <br />aspects, prevent the migration of any hazardous constituent into the <br />ground water or surface water at any future time; <br />(2) control of run—on; <br />(3) control of run—off; <br />(4) management of collection and holding facilities associated with <br />run—on and run—off control systems; and <br />(5) control of wind dispersal of particulate matter, where applicable-, <br />(c) if a double liner and leak detection system is required, as provided <br />by section 66264.301(a), the owner or operator shall submit detailed <br />plans and an engineering report explaining the location of the saturated <br />zone in relation to the landfill, the design of a double—liner system that <br />incorporates a leak detection system between the liners, and a leachate <br />collection and removal system above the liners; <br />(d) a description of how each landfill, including the liner and cover sys- <br />tems, will be inspected in order to meet the requirements of sections <br />66264303(a) and (b). This information shall be included in the inspec- <br />tion plan submitted under section 66270.14(b)(5); <br />(e) detailed plans and an engineering report describing the final cover <br />which will be applied to each landfrli or landfill cell at closure in accor- <br />dance with section 66264.310(a), and adescription of how each landfill <br />will be maintained and monitored after closure in accordance with sec- <br />tion 66264.310(b). This information shall be included in the closure and <br />post—closure plans submitted under section 66270.14(b)(13); <br />(f) if ignitable or reactive wastes will be landfilled, an explanation of <br />how the standards of section 66264.312 will be complied with; <br />(g) if incomoatible wastes, or incompatible wastes and materials will <br />be landfilled, an explanation of how section 66264.313 will be complied <br />with; <br />(h) if containers of hazardous waste are to be landfilled, an explanation <br />of how the repuimments of section 66264.315 or section 66264.316, as <br />applicable, will be complied with; <br />(i) a waste management plan for EPA Hazardous Waste Nos. F020, <br />F021. F022, F023, F026, and F027 describing how a landfill is or will be <br />designed, constructed, operated, and maintained to meet the require- <br />ments of section 66264.317. This submission shall address the following <br />items as specified in stiction 66264.317: <br />(1) the volume, physical, and chemical characteristics of the wastes, <br />including their potential to migrate through soil or to volatilize or escape <br />Into the atmosphere; <br />(2) the attenuative properties of underlying and surrounding soils or <br />other materials-. <br />(3) the mobilizing propertie othermaterials co -disposed with these <br />wastes; and <br />(4) the effectiveness of additional treatment, design, or monitoring <br />techniques. <br />Nam- Authority cited: Sections 208, 25150 and 25159, Health and Safety Code <br />Reference: Sections 25150, 25159 and 25159.5. Health and Safety Code; 40 CFR <br />Section 270.21. <br />HisToRY <br />1. New section filed 5-24-91: operative 7-1-91 (Register 91, No. 22). <br />§ 66270.23. Specific Part B Information Requirements for <br />Miscellaneous Units. <br />Except as otherwise provided in section 66264.600, owners and opera- <br />tors of facilities that transfer, treat, store, or dispose of hazardous waste <br />in miscellaneous units shall provide the following additional informa- <br />tion: <br />(a) a detailed description of the unit being used or proposed for use, in- <br />cluding the following: <br />(1) physical characteristics, materials of construction, and dimensions <br />of the unit; <br />(2) detailed plans and engineering reports describing how the unit will <br />be located, designed, constructed, operated, maintained, monitored, in- <br />spected, and closed to comply with the requirements of sections <br />66264.601 and 66264.602, and <br />(3) fordisposal units, adetaileddesc iption of the plans to comply with <br />the post—closure requirements of section 66264.603; <br />(b) detailed hydrologic, geologic, and meteorologic assessments and <br />land—use maps for the region surrounding the site that address and ensure <br />compliance of the unit with each factor in the environmental performance <br />standards of section 66264.601. If the applicant can demonstrate that the <br />facility does not violate the environmental performance standards of sec- <br />tion 66264.601 and the Department agrees with such demonstration, pre- <br />liminary hydrologic, geologic, and meteorologic assessments will suf- <br />fice; I ` <br />(c) informatiort on the potential pathways of exposure of humans oren <br />vironmentai receptors to waste constituents, hazardous constituents and <br />reaction products, and on the potential magnitude and nature of such ex- <br />posures; <br />(d) for any treatment unit, a report on a demonstration of the effective- <br />ness of the treatment based on laboratory or field data; <br />(e) any additional information determined by the Department to be <br />necessary for evaluation of compliance of the unit with the environmen- <br />tal performance standards of section 66264.601. <br />Nora: Authority cited: Sections 208, 25150 and 25159, Health and Safety Code. <br />Reference: Sections 25150, 25159 and 25159.5. Health and Safety Code: 40 CFR <br />Section 270.23. <br />HLSiORY <br />1. New section filed 5-24--91: operative 7-1-91 (Register 91, No. 22). <br />§ 66270.29. Permit Denial. <br />The Department may, pursuant to the procedures in chapter 21, deny <br />the permit application either in its entirety oras to the active life of a haz- <br />ardous waste management facility or unit only. <br />:Yore Authority cited: Sections 208, 25150 and 25159, Health and Safety Code. <br />Reference. Sections 25150,25 159 and 25159.5,11eaith and Safety Code: 40 CTR <br />Section 27019. <br />HLSrORY <br />New section filed 5-24-91; operative 7-I-91 (Register 91. No. 22). <br />Article 3, Permit Conditions <br />§ 66270.30. Conditions Applicable to All Permits. <br />The following conditions apply to all permits. All conditions aopiiea- <br />ble to permits shall be incorporated into the permits either expressly or <br />byreference.If incorporated by reference, a specific citation to the aeprc- <br />priate regulations shall be given in the permit. <br />a) Duty to comply. The permittee shall comply with all conditions of <br />this permiLexceptthatthe permittee need not comciv with the conditions <br />Page 758.:82 <br />M�t <br />El <br />