My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1990-1993
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
CORRESPONDENCE_1990-1993
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2023 4:13:34 PM
Creation date
10/17/2022 1:45:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1990-1993
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
788
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> 0 <br /> STANDARD PROVISIONS AND REPORTING REQUIREMENTS September 1993 <br /> FOR WASTE DISCHARGE REQUIREMENTS <br /> FOR DISCHARGES REGULATED BY CHAPTER 15 AND/OR PART 258 -8- <br /> must conform to EPA guidelines (e.g., "Laboratory Documentation Requirements for Data <br /> Validation," January 1990, USEPA Region 9) or to procedures approved by the Board. <br /> 5. The director of the laboratory whose name appears on the certification shall supervise all <br /> analytical work in his/her laboratory and shall sign all reports of such work submitted to the <br /> Regional Board. <br /> 6. Unless samples are from water supply wells or unless otherwise specified by the Executive <br /> Officer, all ground water samples to be analyzed for metals shall be field-filtered. Filtration <br /> methods shall minimize the entrainment of air into the sample (by using, for example, in-line <br /> pressure filtration). <br /> Sampling and Analytical Methods <br /> 1. For anv given monitored medium, the samples taken from all Monitoring Points and <br /> Background Monitoring Points to satisfy the data analysis requirements for a given Reporting <br /> Period shall all be taken within a span not exceeding 30 days, unless the Executive Officer <br /> approves a longer time period, and shall be taken in a manner that ensures sample <br /> independence to the greatest extent feasible. <br /> 2. Specific methods of collection and analysis must be identified. Sample collection, storage, <br /> and analysis shall be performed according to the most recent version of USEPA Methods, such <br /> as the latest editions, as applicable, of: (1) "Methods for Organic Chemical Analysis of <br /> Municipal and Industrial Wastewater" (EPA 600 Series), (2) "Test Methods for Evaluating <br /> Solid Waste" (SW 846-latest edition), and (3) "Methods for Chemical Analysis of Water and <br /> Wastes," and in accordance with an approved sampling and analysis plan. <br /> If methods other than USEPA-approved methods or Standard Methods are used, the exact <br /> methodology must be submitted for review and must be approved by the Executive Officer <br /> prior to use. <br /> 3. The methods of analysis and the detection limits used must be appropriate for the expected <br /> concentrations. For detection monitoring of any constituent or parameter that is found in <br /> concentrations which produce more than 90% non-numerical determinations (i.e., "trace" or <br /> "ND") in data from Background Monitoring Points for that medium, the analytical method <br /> having the lowest method detection limit(MDL) shall be selected from among those methods <br /> which would provide valid results in light of any matrix effects or interferences. <br /> 4. "Trace"results—results falling between the MDL and the practical quantitation limit (PQL)— <br /> shall be reported as such, and shall be accompanied both by the estimated MDL and PQL <br /> values for that analytical run. <br />
The URL can be used to link to this page
Your browser does not support the video tag.