REVISIONS <br /> 1 BLDG REV1 12/31/21 <br /> GENERAL MECHANICAL NOTES <br /> MECHANICAL EGEND EQUIPMENT SCHEDULE <br /> 1 . ALL MECHANICAL EQUIPMENT, MATERIAL AND INSTALLATION SHALL COMPLY WITH ALL APPLICABLE <br /> CODES. APPLICABLE CODES SHALL INCLUDE, BUT NOT BE LIMITED TO THE LATEST EDITIONS OF SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br /> THE CALIFORNIA MECHANICAL CODE FOR THE STATE OF CALIFORNIA, CALIFORNIA CODE OF <br /> REGULATIONS (CCR), UNIFORM FIRE REGULATIONS AND TITLE 24 ENERGY EFFICIENCY STANDARD. BALANCE DAMPER <br /> � ,2x4 DIAMETER OR PHASE, DUCT DIMENSIONS (E) AC PACKAGED ROOF TOP AC UNIT, NOMINAL 2.5 TON, WITH <br /> 2. PRIOR TO PURCHASING ANY MATERIAL OR STARTING ANY WORK, CONTRACTOR SHALL FIELD VERIFY 7 BAROMETRIC RELIEF, ELECTRIC COOLING AND HEATING. <br /> ALL EXISTING CONDTIONS, AND SHALL REPORT ANY DEVIATIONS FROM DRAWINGS TO THE SUPPLY DUCT #CARRIER 50HC-030-311 <br /> TOTAL COOLING: 29,000 BTUH QftOFESS/� <br /> ARCHITECT. SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE CONTRACTOR PRIOR _._._ RETURN DUCT TOTAL HEATING: 29,400 BTUH �`�� �9l <br /> TO ORDERING, PURCHASING ANY MECHANICAL EQUIPMENT. AD <br /> `M <br /> AIR FLOW SETTING: 1000 CFM AT 0.5 ESP <br /> 3. ANY EXISTING WALL, FLOOR OR CEILING THAT IS EFFECTED DURING HVAC CONSTRUCTION SHALL BE Z z SUPPLY AIR DIFFUSER, RETURN AIR GRILLE ELECTRICAL: 208/1 /60 <br /> REPAIRED TO MATCH NEW ADJACENT CONDITIONS. EXHAUST AIR GRILLE MCA: 22A <br /> MOCP: 30A * No. 67047 <br /> 4. AFTER CONSTRUCTION, THE ENTIRE HVAC SYSTEM WILL BE TESTED AND BALANCED TO DELIVER AIR OUTSIDE AIR SETTING: 350CFM Exp. 09-30-2022 <br /> QUANTITIES SHOWN ON DRAWING. AIR SYSTEMS SHALL BE BALANCED BY A QUALIFIED MECHANICAL THERMOSTAT T civ <br /> USING AABC SMACNA OR NEBB PROCEDURES. AIR QUANTITIES SHALL BE BALANCED (E) CEF COOK MODEL #: GC220 OR EQUAL F OF CNF <br /> CONTRACTOR, CFM, CUBIC FEET OF AIRFLOW PER MINUTE 1 <br /> TO NOT MORE THAN 10% ABOVE OR 0% BELOW THE QUANTITIES SHOWN ON THE DRAWINGS. CEILING EXHAUST FAN <br /> CONTRACTOR SHALL SUBMIT A COMPLETE AIR BALANCE REPORT INDICATING, AS A MINIMUM, THE SD SMOKE DETECTOR AIR FLOW SETTING: 80 CFM AT 0. 125 S.P. <br /> AIR DELIVERY FOR EACH DIFFUSER, THE FINAL OPERATING DATA FOR THE SYSTEMS AND THE AIR ELECTRICAL: 120/1 /60, 60WATTS <br /> CONDITIONING UNITS. WEIGHT: 15 LBS <br /> CONTROL WITH ROOM LIGHT <br /> AIR BALANCE FURNISH WITH BACKDRAFT DAMPER, INTERCONNECTING <br /> 5. CONTRACTOR SHALL COORDINATE INSTALLATION OF ALL NEW WORK, MATERIALS, EQUIPMENT, ETC. MARK SUPPLY AIR RETURN AIR OUTSIDE AIR MAKEUP AIR EXHAUST AIR NET DIFFERENCE DUCT, THERMAL MOTOR PROTECTION, TIME DELAY <br /> WITHIN THE SPACE ALLOWED BY STRUCTURAL CONDITIONS. THE LOCATION OF ALL ROOF MOUNTED SWITCH, SPEED CONTROLLER MOUNTED ON UNIT <br /> EQUIPMENT WITH THE STRUCTURAL ENGINEER. HEF CASING, ROOF CAP. <br /> CONTRACTOR SHALL FIELD COORDINATE AND INSTALL PACKAGED ROOFTOP EQUIPMENT TO 1 0 0 0 0 350 -350 INTERLOCKED WITH RESTROOM LIGHTING OCCUPANCY <br /> MAINTAIN A MINIMUM OF 10'-0" CLEARANCE FROM OUTSIDE AIR INTAKE TO ALL EXHAUST OUTLETS AC SENSOR <br /> AND (VTR) VENT THRU ROOF, TYPICAL. 1 1000 650 350 0 0 +350 HEF HOOD EXHAUST FAN FOR TYPE II HOOD. <br /> 6. THE DIAGRAMS ARE DIAGRAMMATIC AND DO NOT DEPICT EXACT CONDITIONS. THE LOCATION OF 1 SEE CAPTIVE AIRE HOOD SHEETS <br /> EQUIPMENT, DUCTWORK AND PIPING ETC IS APPROXIMATE ONLY. MATERIALS, EQUIPMENTS OR LABOR TOTALS 1000 650 350 0 350 -100 <br /> NOT INDICATED BUT WHICH CAN BE REASONABLY INFERRED TO BE NECESSARY FOR A COMPLETE <br /> INSTALLATION SHALL BE PROVIDED. DRAWINGS DO NOT UNDERTAKE TO DEPICT EVERY ITEM OF <br /> MATERIAL, EQUIPMENT OR LABOR REQUIRED TO PRODUCE A COMPLETE AND OPERATING HVAC GRILL SCHEDULE <br /> SYSTEM. <br /> 7. ALL REQUIRED CONTROLS, CONTROL WIRING, WIRING AND EQUIPMENT TO PROVIDE POWER FOR HVAC SYMBOL DESCRIPTION <br /> CONTROLS NOT INDICATED ON PLANS SHALL BE THE RESPONSIBILITY OF MECHANICAL CONTRACTOR. <br /> 8 <br /> ALL EQUIPMENTS SUPPLYING MORE THAN 2000 CFM OF AIR TO NY SPACE SHALL BE PROVIDED S 1 TITUS MODEL TMS OR EQUAL, LOUVERED FACE, ALL STEEL WITH A DUCT SMOKE DETECTOR N THE SUPPLY DUCTWORK. THE DUCT SMOKE DETECTOR SHALL BE CONSTRUCTION LAYIN 24"X24" T BAR FRAME, WITH OPPOSED <br /> BLADE DAMPER. <br /> WIRED TO STOP THE EQUIPMENT UPON DETECTION OF SMOKE AND SIGNAL THE FIRE ALARM <br /> CONTROL PANEL. THE SMOKE DETECTOR SHALL BE FURNISHED, MOUNTED IN THE DUCT BY S2 TITUS MODEL 30ORL OR EQUAL, LOUVERED FACE, ALL STEEL <br /> MECHANICAL CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. CONSTRUCTION, SIDE, DUCT MOUNTED, WITH OPPOSED BLADE <br /> 9. SUPPLY, RETURN AND AIR DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEETMETAL IN DAMPER. <br /> ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS' LATEST EDITION. ALL JOINTS AND S3 TITUS MODEL TDC OR EQUAL, LOUVERED FACE, ALL STEEL <br /> SEAMS IN DUCTWORK SHALL BE SEALED WITH DUCT SEALER. ALL DUCT JOINTS INCLUDING CONST, 12"X12" SURFACE MOUNT, WITH OPPOSED BLADE <br /> MECHANICAL FLANGED JOINTS SHALL BE SEALED WITH SILVER TAPE, OR ARABOL AND CANVAS. DAMPER. <br /> SEAL THE JOINTS OF ALL DUCTS EXPOSED TO THE WEATHER WITH ARABOL AND CANVAS. PROVIDE <br /> ALL BRANCH DUCTS WITH VOLUME DAMPERS WITH LOCKING QUADRANTS LOCATED AT LEAST FIVE R1 TITUS MODEL 350ZRL, 18"X18" EGGCRATE RETURN GRILL, <br /> FEET (5) FROM THE GRILLE OR DIFFUSER SERVED. SURFACE MOUNTED BORDER TYPE 1 . STANDARD WHITE FINISH. <br /> 10. EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL CONSTRUCTED SMACNA STANDARDS AND <br /> SHALL NOT BE INSULATED UON. <br /> 11 . ALL DUCTWORK SHALL BE SUPPORTED BY BUILDING STRUCTURE AND NOT WITH CEILING TILES OR Z <br /> CEILING STRUCTURE. SUPPORTS FOR ALL PIPING AND DUCTWORK SHALL BE IN ACCORDANCE WITH Q <br /> SMACNA "GUIDELINES FOR SEISMIC RESTRAINT OF MECHANICAL SYSTEMS". CONTRACTOR SHALL <br /> PROVIDE CALCULATIONS FOR ISOLATORS AND MOUNTING ACCEPTABLE TO AHJ WHEN REQUIRED <br /> BY AHJ. <br /> 0 <br /> 12. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX M-KE OR EQUAL. PROVIDE MIN INSULATION VALUE OF <br /> R-6, R-8 WHEN LOCATED OUTSIDE THE THERMAL ENVELOPE OF THE BUILDING.FLEX DUCT DIAMETER V 0 �O <br /> SHALL MATCH EQUIPMENT NECK DIAMETER. MAINTAIN MAXIMUM FLEX DUCT LENGTH OF 5-0". <br /> FLEXIBLE DUCTS SHALL NOT BE USED WHERE EXPOSED DUCTWORK OCCURS. SUPPORT FLEXIBLE Z m � <br /> DUCTS WITH 2" WIDE HANGER STRAPS. a <br /> 13. DUCT DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. COORDINATE = U <br /> LOCATIONS OF REGISTERS, GRILLES AND DIFFUSERS WITH LIGHTS, CEILING GRID ETC IN FIELD. <br /> INSULATE ALL SHEET METAL SUPPLY AND RETURN DUCTS WITH JOHNS MANVILLE MICROLITE XG OR = Q <br /> 14. <br /> EQUAL UL LISTED FIBERGLASS BLANKET INSULATION WITH FOIL VAPOR BARRIER. PATCH TEARS IN 0 <br /> FOIL JACKET WITH FOIL TAPE TO MAINTAIN THE INTEGRITY OF VAPOR BARRIER. SHEET METAL 0U SUPPLY AND OUTSIDE AIR DUCTWORK SHALL BE 2" THICK, 1 LB/FT3 DENSITY R-8 MIN. LAP ALL <br /> JOINT 4" MINIMUM, AND SECURE WITH GALVANIZED STEEL WIRE. KITCHEN HOOD EXHAUST DUCTWORK 0" Q <br /> SHALL BE INSULATED PER NEPA 96 AND LOCAL CODES. KITCHEN HOOD SUPPLY DUCTWORK SHALL 0 Lo <br /> BE INSULATED AS SPECIFIED FOR HVAC SUPPLY DUCTWORK. N 011-- <br /> 15. <br /> �15. LINE ALL SHEET METAL SUPPLY AND RETURN DUCT DROPS FOR A MINIMUM OF 15' FROM THE UNIT <br /> WITH 1-1/2" THICK(MIN R-6) JOHNS MANVILLE PERMACOTE LINACOUSTIC R-300 OR EQUAL. <br /> 16. PROVIDE PERMANENT ENGRAVED PLASTIC NAME PLATED FOR ALL EQUIPMENT INSTALLED, DATE 09/15/2021 <br /> INDICATING THE PLAN DESIGNATION OF THE UNIT (AC-1, REF., ETC.) AND ALSO THE BUILDING SCALE AS <br /> AREA SERVED (CLASSROOMS 2-4, CONFERENCE ROOM, ETC.). NOTED <br /> DRAWN <br /> MSK <br /> 17. ALL HVAC EQUIPMENTS & DUCTS SHALL BE COVERED AND SEALED FROM DELIVERY ON SITE PER JOB 21035 <br /> CGBSC SECTION 5.504.3. <br /> SHEET TITLE <br /> 18. PROVIDE A MINIMUM OF MERV 8 RATING FILTERS ON OUTSIDE AIR AND RETURN AIR PER CGBSC MECHANICAL <br /> SECTION 5.504.5.3 ON ALL NEW HVAC UNITS. <br /> 19. ANY TENANT EQUIPMENT TO BE INSTALLED ON THE LANDLORD'S ROOF MUST BE INSTALLED AS PER NOTES <br /> THE REQUIRED DETAILS THAT HAVE BEEN PROVIDED BY THE LANDLORD. PLEASE SEE DESIGN SCHEDULES <br /> SPECIFICATIONS, PROVIDED UNDER A SEPARATE COVER, BY THE LANDLORD FOR SAID DETAIL. AND <br /> 20. EQUIPMENT, VENTS, EXHAUST FANS CANNOT BE HIGHER THAN THE PARAPET WALL IN THE ROOF LEGEND <br /> WELL AREA. ALL ROOF EQUIPMENT, VENT LINES, CONDUIT DURING THE TI CONSTRUCTION ON ROOF <br /> MUST BE PAINTED TO MATCH THE EXISTING ROOF COLOR. <br /> 21 . CONDENSATE DRAIN LINES MUST IMMEDIATELY PENETRATE ROOF AND RUN ALONG THE UNDERSIDE SHEET <br /> OF ROOF STRUCTURE. EXTERIOR WALL PENETRATIONS RELATING TO TI WORK IS PROHIBITED. M 1 4 0 <br />