REVISIONS <br /> GENERAL PLUMBING NOTESPLUMBING LEGEND PLUMBING FIXTURES SCHEDULE 1 BLDG REV1 12/31/21 <br /> CATHODIC PROTECTION: <br /> 1 . ALL EQUIPMENT, MATERIALS AND INSTALLATION SHALL BE IN 4. ID ITEM DESCRIPTION <br /> ACCORDANCE WITH ALL APPLICABLE CODES. APPLICABLE CODES WRAP ALL BELOW GRADE COPPER OR STEEL WATER AND GAS SYMBOL DESCRIPTION <br /> SHALL INCLUDE, BUT NOT BE LIMITED TO THE LATEST EDITIONS PIPING INCLUDING JOINTS AND FITTINGS WITH TWO LAYERS OF FD FLOOR DRAIN J.R. SMITH # 2005A, 5" DIAMETER NICKEL BRONZE TOP <br /> OF THE CPC, CMC, CALIFORNIA CODE OF REGULATIONS (CCR), PASCO-WRAP, OR SIMILAR MATERIALS, s s NEW WASTE SEWER BELOW GRADE OR SLAB WITH 2' PIPE, FLANGE AND SEEPAGE PAN. PROVIDE <br /> UNIFORM FIRE REGULATIONS AND TITLE 24 ENERGY EFFICIENCY GW NEW GREASE WASTE BELOW GRADE OR SLAB TRAP PRIMER CONNECTION, OR EQUAL. <br /> STANDARDS. 5• INSULATION: <br /> WRAP ALL HOT WATER SUPPLY AND RETURN PIPING, JOINTS AND NEW VENT PIPING FS FLOOR SINK SMITH # 325-YO3 WITH CAST IRON BODY, ENAMELED <br /> FITTINGS WITH 1 " THICK FIBERGLASS SNAP-ON INSULATION TO NEW COLD WATER PIPING INTERIOR, 6" DEEP SUMP, FLANGE AND SEEPAGE PAN, <br /> 2. PIPING MATERIALS SHALL BE AS FOLLOWS: ALUMINUM BOTTOM DOME STRAINER � QftOFESS/0 <br /> , HALF GRATE, 2" ,y91 <br /> SATISFY A COMBINED THERMAL RESISTIVITY OF R- 16, PER CPC NEW HOT WATER PIPING �`� MAD 0 F <br /> 609. 11 .2 OUTLET, CAULK JOINT, OR EQUAL. <br /> a. WASTE, VENT, SEWER AND STORM PIPING, <br /> COUPLING AND - � � � - NEW GAS PIPING <br /> FITTING SHALL BE PVC CONFORMING TO ASTM D 1785. 6. INSTALLATION: -FW-FW NEW FILTERED WATER MS MOP SINK JOHN BOOS #PBMS2016-6-X FLOOR MOUNTED, 3.5 <br /> PLASTIC SOLVENT CEMENT FOR PVC PLASTIC PIPE SHALL OUTLET WITH AMERICAN STANDARD #8344.012 FAUCET <br /> CONFORM TO ASTM D 2235. ACID RESISTANT WASTE AND INSTALL ALL PIPING IN ACCORDANCE WITH THE UNIFORM DF4 SOV SHUT OFF VALVE WITH TOP BRACE, STOPS AND VACCUUM BREAKER, AND * No. 67047 <br /> VENT SHALL BE SCHEDULE 40 PVC. PLUMBING CODE & STATE OF CPC. CAREFULLY GRADE ALL WASTE AUTOMATIC GAS SHUT-OFF VALVE AMERICAN STANDARD #721 .038 DRAIN WITH STRAINER, Exp. 09-30-2022 <br /> b. CONDENSATE PIPING SHALL BE TYPE L COPPER TUBING PIPING TO ENSURE A UNIFORM SLOPE IS ACHIEVED, WITHOUT ANY OR EQUAL. /VIS- <br /> PER ASTM B88 AND WROUGHT CABLE FITTING. DIPS OR HIGH POINTS IN THE PIPING. PROVIDE SHOCK FCO GRADE CLEAN OUT, FLOOR CLEAN OUT 9TF OF CFO�� <br /> c. ABOVE GRADE HOT AND COLD WATER PIPES SHALL BE TYPE ABSORBERS AT HOT AND COLD WATER AT ALL FIXTURES. ® FD FLOOR DRAIN BP BACKFLOW WATTS: 0091 QT-S, 4" SIZE, BRONZE BODY, BALL <br /> CHLORINATE ALL WATER PIPING FOR A PERIOD OF 8 HOURS, BY PREVENTER VALVES, AND TEST COCKS. FURNISH WITH STRAINER <br /> M COPPER TUBING, HARD-TEMPER, WITH WROUGHT COPPER CHARGING WITH A CHLORINE OR HYPO CHLORITE SOLUTION TO � FS FLOOR SINK INSTALLED UPSTREAM OF BACKFLOW PREVENTER. <br /> FITTINGS. 95-5 TIN/ANTIMONY OR SIMILAR LEAD FREE ACHIEVE A 5 PPM STRENGTH AT THE FIXTURE FURTHEST FROM 1_4 POC POINT OF CONNECTION <br /> SOLDERING MATERIAL SHALL BE USED. CAPPED OR PLUGGED WC WATER CLOSET ACCESSIBLE WATER CLOSET: KOHLER #K-3999 HIGHLINE <br /> OUTLETS SHALL BE SCHEDULE 40 SCREWED BRASS. ELBOWS THE POINT OF APPLICATION. UPON COMPLETION OF VTR VENT THROUGH ROOF FLOOR MOUNTED, WHITE VITEROUS CHINA, 16.5" HIGH <br /> AT BRANCH OUTLETS SHALL BE SCREWED OUTLET, WITH <br /> CHLORINATION, FLUSH ALL PIPING UNTIL NO CHLORINE CAN BE TDL TOTAL DEVELOPED LENGTH ELONGATED SIPHON ACTION BOWL, CLOSE COUPLED <br /> EARS, FOR NAILING OR SCREWING TO WALL BACKING. DETECTED BY TASTE. AFTER CHLORINATION AND ALL TESTING HAS (E) EXISTING TO REMAIN AS IS TANK, 1 .28GPF, TRIP LEVER ON OPEN SIDE WITH BOLT <br /> c. BELOW GRADE HOT AND COLD WATER PIPE SHALL BE TYPE BEEN COMPLETED, CLEAN ALL FIXTURE STRAINERS, AND SET CAPSAND KOHLER K-4670C OPEN FRONT SEAT LESS <br /> WATER FLOWS FROM FIXTURES IN ACCORDANCE WITH THE (ER) EXISTING TO BE RELOCATED COVER. ALL COMPONENTS SHALL BE WHITE. UNIT SHALL <br /> L COPPER TUBING, HARD-TEMPER, WITH WROUGHT COPPER REQUIREMENTS OF T24, CCR. CONFORM TO ADA AND T24 REQUIREMENTS FOR <br /> FITTINGS. SILVER SOLDERING SHALL BE USED BELOW GRADE. ACCESSIBLE INSTALLATION, OR EQUAL. <br /> d. ABOVE GROUND GAS PIPING SHALL BE STANDARD WEIGHT, 7. TESTS ON DIFFERENT PLUMBING PIPING SHALL BE AS FOLLOWS: <br /> SCHEDULE 40, BLACK STEEL, STM A-53, WITH 150# BLACK GAS SIZING CHART L LAVATORY LAVATORY: KOHLER 2005 KINGDTON WALL HUNG <br /> MALLEABLE IRON FITTINGS. ALL UNDERGROUND GAS PIPES VITEROUS CHINA FRONT OVERFLOW WITH KOHLER <br /> AND ABOVE GROUND PIPE SIZES 3" AND OVER SHALL a. TEST ALL GAS PIPING FOR A PERIOD NOT LESS THAN TWO GAS (M H) PROVIDED CHROME PLATED FAUCET MODEL 15598-5P SINGLE <br /> HOURS ATA PRESSURE OF NOT LESS THAN 10 PSIG, USING SYMBOL FIXTURE DESCRIPTION LOAD TDL(FT) MIN SIZE (INCH) (INCH) LEVER, 4" CENTERSET, AERATOR 0. 18 GP CYCLE & <br /> HAVE WELDED JOINTS. SIZES 2- 1 /2" AND SMALLER SHALL SOAP AND WATER OR SIMILAR MATERIALS AT ALL JOINTS. WELDED METAL GRID DRAIN ASSEMBLY. INSULATE WATER AND <br /> BE THREADED OR WELDED JOINTS. GAS PIPING SHALL BE TESTED PER UPC/CPC. WASTE PIPING. UNIT SHALL CONFORM TO ADA AND T24 <br /> b. TEST ALL WASTE AND VENT PIPING FOR A PERIOD OF NOT REQUIREMENTS FOR ACCESSIBLE INSTALLATION, OR <br /> 3. PIPING AND EQUIPMENT ACCESSORIES SHALL BE AS FOLLOWS: LESS THAN 8 HOURS BY CAPPING OR PLUGGING ALL JOINTS TO GWH-1 300 40 1 " 1 " EQUAL. <br /> A LEVEL OF THE HIGHEST FIXTURE OR FITTING, FILLING THE „ GWH1 GAS WATER HEATER: NORITZ NCC-30ODV, GAS FIRED, 97% <br /> a. PROVIDE ELBOWS AT ALL PIPING PENETRATIONS OF WALLS SYSTEM WITH WATER, AND OBSERVING FOR LEAKS. TEST 14 GAS OVEN 53+53 40 3/4 3/4 WATER HEATER EFFICIENCY, NON CONDENSING TYPE, 300MBH MAX, <br /> TO STOPS. ELBOWS SHALL HAVE NAILING EARS, AND SHALL UNDERGROUND SECTION OF PIPE WITH A RISER TO ACHIEVE THE SEALED COMBUSTION, POWER/DIRECT VENT, (9.7 GPM <br /> BE SECURELY FASTENED TO THE STRUCTURE. NIPPLES PRESSURE EQUIVALENT TO THE HIGHEST FIXTURE OR FITTING. 406 40 1 -1/4" 1 -1/4" Q 60 DEG RISE) <br /> THROUGH THE WALLS SHALL BE IPS WEIGHT THREADED C. TEST WATER PIPING AT 100 PSIG FOR A PERIOD OF EIGHT <br /> COPPER OR BRASS. HOURS, OBSERVING FOR ANY VISIBLE LEAKS. TEST PIPING AGAIN GI-1 GREASE INTER- GREASE INTERCEPTOR: BIG DIPPER 40LB, 20GPM FLOW <br /> b. PROVIDE TRAPS FOR ALL FIXTURES WITH INTEGRAL WITH FIXTURES INSTALLED AT 60 PSIG. FIXTURE CONNECTION SCHEDULE CEPTOR RATE, 3" INLET/OUTLET, WHITE DUCO COATING INSIDE <br /> CLEANOUT. AND OUTSIDE, FLOW CONTROL FITTING, LIFT OUT <br /> c. PROVIDE CHROME PLATED ESCUTCHEON PLATES WITH SPRING 8. ROUTE CONDENSATE PIPING FROM EQUIPMENT TO NEAREST WASTE WATER SEDIMENT BUCKET. <br /> TAB ON ALL PIPES PASSING THROUGH WALLS OR CEILINGS. APPROVED RECEPTOR. ALL CONDENSATE SYSTEMS SHALL SYMBOL FIXTURE DESCRIPTION VENT <br /> d. ALL EXPOSED PIPING SHALL BE CHROME PLATED. TERMINATE INTO THE STORM DRAINAGE SYSTEM, UNLESS NOTED DIRECT IND. CW HW <br /> e. PROVIDE CLEVIS TYPE HANGERS WITH CUSHIONING TO OTHERWISE, AND SHALL OTHERWISE BE INSTALLED IN <br /> PREVENT SWAYING AND VIBRATION FOR ALL PIPING. PROVIDE ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. FD 2" FLOOR DRAIN 1 -1/2 2 - - - DOMESTIC WATER CALCULATIONS <br /> FELT LINING OR PLASTIC WRAPPING BETWEEN DISSIMILAR CONNECT TO EQUIPMENT WITH VENTED P-TRAP. <br /> METALS TO AVOID ELECTROLYSIS. FS 2" FLOOR SINK 1 -1/2 2 - - - FIXTTYPE NO COLD HOT WASTE <br /> f. PROVIDE WRAP ON WASTE, HOT AND COLD WATER PIPING 9. PROVIDE ACID RESISTANT PIPING FROM SODA MACHINE TO POINT WC WATER CLOSET 2 3 - - - FU TOTAL FU TOTAL FU TOTAL <br /> UNDER ADA ACCESSIBLE PLUMBING FIXTURES. OF DILUTION. ACID RESISTANT WASTE AND VENT SHALL BE <br /> LAVATORY 1 0.75 0.75 0.75 0.75 1 1 <br /> SCHEDULE 40 PVC. L LAVATORY 1 -1/2 2 - - - WATER CLOSET 1 2.5 2.5 0 0 4 4 <br /> 10. CONDENSATE DRAIN LINES MUST IMMEDIATELY PENETRATE ROOF AND RUN 13 HAND-SINK 1 -1/2 2 - 1/2 1/2 URINAL 0 20 0 0 0 2 0 <br /> ALONG THE UNDERSIDE OF ROOF STRUCTURE. EXTERIOR WALL PENETRATIONS MOP SINK 1 2.25 2.25 2.25 2.25 3 3 <br /> RELATING TO TI WORK IS PROHIBITED. 23 PREP-SINK 2 - 2 1/2 1/2 FLOOR DRAIN/SINK 2 0 0 0 0 2 4 <br /> 22 3 COMPARTMENT SINK 1 -1/2 2 - 1/2 1/2 HANDSINK 2 1.5 3 1.5 3 2 4 Z <br /> SINK _ _ PREP SINK 1 1.5 1.5 1.5 1.5 2 2 <br /> MOP <br /> 24 1 1/2 2 1/2 1/2 <br /> 3 COMP SINK 1 1.5 1.5 1.5 1.5 4 4 CL <br /> 31 SODA-MACHINE 1 -1/2 - 2 - - MISC EQUIP 2 1 2 0 0 1 2 <br /> 31.1 ICE-MACHINE /2 <br /> 1 -1/2 - 2 1 - TOTAL FU 1 1 13.5 9 24 O <br /> � <br /> ALL INDIRECT WASTE CONNECTION WILL BE DONE VIA FLOOR SINK. SEE SHEET P2.0 FOR EQUIVALENT COLD WATER FLOW RATE (GPM) 13 GPM U C)PRESSURE AVAILABLE AT MAIN 40 PSI in > � <br /> FLOOR SINK LOCATION AND SHEET P3.0 FOR DETAIL. J <br /> MINIMUM REQUIRED PRESSURE 8 PSI Z m LOELEVATION RISE 12 FT 5 PSI Q CO <br /> GREASE INTERCEPTOR SIZE METER LOSS 3 PSI = <br /> BACK FLOW PREVENTER LOSS 10 PSI U <br /> TOTAL EQUIVALENT PIPE LENGTH FROM METER 100 FT = Q U <br /> PLUMBING FIXTURES QTY DFUs DFUs FRICTION LOSS PRESSURE AVAILABLE (PSI) 13.79 O • <br /> MAX ALLOWABLE FRICTION LOSS (PSI/100FT) 13.79 0 <br /> 3 COMP. SINK 1 6 6 WATER FLOW VELOCITY (FPS) 5.05 v) U <br /> TOTAL DFUs 6 CIRCULATION FRICTION LOSS (PSI/100FT) 5.66 Q. Q <br /> O L � <br /> MINIMUM GREASE WASTE SIZE REQUIRED 3„ MINIMUM REQUIRED WATER PIPE SIZE 1.0" N 01,_ ~ <br /> MINIMUM HGI SIZE REQUIRED 20GPM MINIMUM REQUIRED WASTE PIPE SIZE 3.0" <br /> 1 <br /> DATE <br /> 09/15/2021 <br /> SCALE AS <br /> NOTED <br /> DRAWN <br /> MSK <br /> JOB 21035 <br /> SHEET TITLE <br /> PLUMBING <br /> NOTES, <br /> SCHEDULES <br /> AND <br /> LEGEND <br /> SHEET <br /> 01 . 0 <br />