My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAROLYN WESTON
>
721
>
1600 - Food Program
>
PR0547908
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2022 11:16:14 AM
Creation date
10/18/2022 11:15:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547908
PE
1624
FACILITY_ID
FA0027312
FACILITY_NAME
STARBUCKS COFFEE #58653
STREET_NUMBER
721
STREET_NAME
CAROLYN WESTON
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
CURRENT_STATUS
01
SITE_LOCATION
721 CAROLYN WESTON BLVD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Item # EF -60T -125E -3N, Commercial eF Series® Ultra -High Efficiency Energy Saver G... Page 4 of 5 <br />• Factory Installed Hydrojet® Sediment Reduction System - Cold water inlet sediment reducing device helps <br />prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build <br />up in tank. <br />• Water Connections - Factory installed true dielectric waterway fittings extend water heater life and eases <br />installation. <br />Hand Hole Cleanout - Allows inspection of tank interior and facilitates the removal of sediment deposits. <br />E.C.O. - A manual re -set Energy Cut Off (E.C.0) shuts off all gas in event of an overheat condition. The ECO is <br />manually resettable. <br />Non -CFC Foam Insulation - Covers the sides and top of tank, reducing the amount of heat loss. This results in <br />less energy consumption, improved operation efficiencies and jacket rigidity. <br />Features <br />• Thermal Efficiency up to 99.1% - Ultra High Efficiency results in less fuel consumption and greater hot water <br />recovery. <br />• ICON HDTM - Intelligent proven design combines temperature control, diagnostic codes, and system ignition <br />functions into a single control board with a digital LCD display. <br />• Factory Installed Hydrojet® Sediment Reduction System - Cold water inlet sediment reducing device helps <br />prevent sediment build up in the tank. <br />Direct Spark Ignition - For improved operational dependability and durability. <br />Operation Mode - Two different digitally displayed operation modes have the capability of adjusting the <br />temperature setting up to 180 OF (82 °C), and adjusting the degree setting (°F to °C, or °C to °F). <br />Service Mode - Eight different digitally displayed service screens can be easily cycled through by pressing the <br />select button. There is the capability of adjusting the temperature setting up to 180 OF (82 °C), adjusting the <br />degree setting (°F to °C, or °C to °F), locking the maximum temperature setting that can be adjusted in operation <br />mode, displaying the temperature sensor reading, displaying the flame current, and displaying diagnostic codes. <br />Premix Power Burner - A self compensating negative regulation system automatically increases or decreases <br />fuel flow when a change in combustion air is detected. This provides the range for optimum combustion and <br />efficiency (automatic high altitude compatibility). <br />Flexible Venting - The eF Series® can vent vertically or horizontally with either 2", 3" or 4" PVC, CPVC or ABS <br />(not approved for Canada) vent pipe, and is approved for direct vent closed combustion applications, or those <br />applications that require inside air for combustion. Foam Core pipe is permitted on the entire venting system. <br />The eF Series® is also approved for unbalanced venting, which means the air intake pipe doesn't have to be <br />vented the same distance as the exhaust. <br />1" NPT Side Connections for Space Heating. <br />Sanitizing Capability - Temperature setting up to 180 OF (82 °C). <br />Complies with the latest ultra-low NOx requirement (14 ng/J NOx limit). <br />ASME Code Available on All Models. <br />NSF Construction Available. <br />• T&P Relief Valve - Installed. <br />• Low Restrictive Brass Drain Valve - Durable tamper proof design. <br />Warranty <br />• 3 or 5 -Year Limited Tank Warranty. <br />• 1 -Year Limited Warranty on Component Parts. <br />Note <br />Air intake cannot exceed exhaust by more than 30 ft. in any venting situation. Subtract 5 ft. for each additional 900 <br />elbow. <br />All models comply with the latest ultra-low NOx requirements of 14 ng/J or less. Amp Draw range = 1.0 to 1.8 amps. <br />14.0" w.c. maximum static, 4.5" w.c. minimum running (Recommend 7.0" w.c. minimum running) <br />Concentric Vent Kit Termination - 3" termination fitting provides for only one exit opening through wall or roof (p/n 239- <br />http://catalog.waterheatersales.com1printitemlall-categorieslhigh-efficiency-energy-saver-g... 8/14/2020 <br />
The URL can be used to link to this page
Your browser does not support the video tag.