Laserfiche WebLink
Case Narrative <br /> Client: Geosyntec Consultants, Inc. TestAmerica Job ID: 320-47216-1 <br /> Project/Site: WR2501 Port of Stockton <br /> Job ID: 320-47216-1 <br /> Laboratory: TestAmerica Sacramento <br /> Narrative <br /> Job Narrative <br /> 320-47216-1 <br /> Comments <br /> No additional comments. <br /> Receipt <br /> The samples were received on 1/29/2019 4:35 PM;the samples arrived in good condition, properly preserved and,where required, on ice. <br /> The temperatures of the 2 coolers at receipt time were 2.10 C and 2.4°C. <br /> Receipt Exceptions <br /> The container label for the following sample did not match the information listed on the Chain-of-Custody(COC): PS-UST-SS-517-01A-4 <br /> (320-47216-1). One out of three VOA containers was labeled PST-UST-SS-517-01A-4,while COC lists PS-UST-SS-517-01A-4. The <br /> samples were logged in according to COC. The soil jar containers matched the COC. <br /> The following sample was received with headspace in the sample containers: IDW-W-012819(320-47216-14).All three voa vials were <br /> received with air bubble larger then 6mm. <br /> GUMS VOA <br /> Method(s)8260B:The laboratory control sample(LCS)and laboratory control sample duplicate(LCSD)for analytical batch 320-274191 <br /> recovered outside control limits for the following analytes: Bromoform. These analytes were biased high in the LCS/LCSD and were not <br /> detected in the associated samples;therefore,the data have been reported. <br /> Method(s)8260B:The method blank for analytical batch 320-274191 contained 1,2,4-Trichlorobenzene, 1,2,3-Trichlorobenzene and <br /> Naphthalene above the method detection limit. This target analyte concentration was less than the reporting limit(RL);therefore, <br /> re-extraction and/or re-analysis of samples was not performed. <br /> Method(s)8260B: Insufficient sample volume was available to perform a matrix spike/matrix spike duplicate(MS/MSD)associated with <br /> analytical batch 320-274191. <br /> Method(s)8260B:The laboratory control sample(LCS)for preparation batch 320-273828 and analytical batch 320-275307 recovered <br /> outside control limits for the following analytes: Bromomethane. These analytes were biased high in the LCS and were not detected in the <br /> associated samples;therefore,the data have been reported. <br /> Method(s)8260B:The following sample was diluted to bring the concentration of target analytes within the calibration range: <br /> PS-UST-SS-817B-04A-4(320-47216-6). Elevated reporting limits(RLs)are provided. <br /> Method(s)8260B: Insufficient sample volume was available to perform a matrix spike/matrix spike duplicate(MS/MSD)associated with <br /> preparation batch 320-273828 and analytical batch 320-275307. <br /> Method(s)8260B:The following volatiles sample was diluted due to foaming at the time of purging during the original sample analysis: <br /> IDW-W-012819(320-47216-14). Elevated reporting limits(RLs)are provided. <br /> Method(s)8260B: Internal standard (ISTD)response for TBA-d9(IS)and Dioxane-d8(IS)for the following samples were outside <br /> acceptance criteria: IDW-W-012819(320-47216-14), (LCSD 320-275439/6)and (MB 320-275439/9). This ISTD does not correspond to <br /> any of the requested target compounds;therefore,the data have been reported. <br /> Method(s)8260B:The following volatile sample dilution was analyzed with significant headspace in the sample container: <br /> IDW-W-012819(320-47216-14). Significant headspace is defined as a bubble greater than 6 mm in diameter. <br /> Method(s)8260B/CA_LUFTMS: Reanalysis of the following sample was performed outside of the analytical holding time due to addition of <br /> the GRO method after the hold time : PS-UST-SS-9168-01A-4 (320-47216-8).This method was missed at the time of sample login. <br /> No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br /> TestAmerica Sacramento <br /> Page 4 of 57 2/15/2019 <br />