Laserfiche WebLink
SAN J OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Hazardous Materials Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> COMPLETE WELDERS SUPPLY INC 1549 N BROADWAY AVE, STOCKTON October 19, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 4 HSC 25508(a)(1) Failed to electronically submit the Business Activities or Owner/Operator Identification page. <br /> OBSERVATION: The Business Owner/Operator Identification form was not accurate. The Business Primary <br /> Emergency Contact, Nick Saad has not been affiliated with this facility since August 29, 2022. The current contact <br /> is Andres Cardenas. <br /> REGULATION GUIDANCE: This information must be current and submitted as part of the business plan. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calep;a.ca.gov/, enter the correct or updated information, and submit to the EHD for approval. <br /> This is a Class II violation. <br /> 5 HSC 25505(a)(1) Failed to electronically submit hazardous materials inventory for all reportable materials on site. <br /> OBSERVATION: The Hazardous Materials Inventory was not complete/accurate. <br /> 1. Butane–the storage pressure was wrongly reported as ambient vs. above ambient. <br /> 2. Acetylene -the storage temperature was wrongly reported as above ambient vs. ambient. <br /> 3. Hydrogen compressed gas -the storage pressure and storage temperature elements have not been completed. <br /> 4. Nitrogen compressed -the storage pressure was wrongly reported as ambient vs. above ambient. <br /> 5. Argon compressed -the storage pressure was wrongly reported as ambient vs. above ambient. <br /> 6. Oxygen, liquid -the storage pressure was wrongly reported as ambient vs. above ambient. <br /> 7. Sulfur dioxide-the storage pressure was wrongly reported as ambient vs. above ambient. <br /> 8. Nitrogen refrigerated liquid -the storage pressure was wrongly reported as ambient vs. above ambient and the <br /> storage temperature is wrongly reported as ambient vs. below ambient. <br /> 9. Anhydrous ammonia -the storage pressure was wrongly reported as ambient vs. above ambient. <br /> 10. Oxygen compressed -the storage pressure was wrongly reported as ambient vs. above ambient. <br /> 11. Argon mixed with carbon dioxide -the storage pressure and storage temperature elements have not been <br /> completed. <br /> 12. Carbon dioxide bulk-the storage pressure was wrongly reported as ambient vs. above ambient. <br /> 13. Carbon dioxide compressed -the storage pressure was wrongly reported as ambient vs. above ambient. <br /> REGULATION GUIDANCE: The Hazardous materials inventory information must be current and submitted as part <br /> of the business plan. <br /> CORRECTIVE ACTIONS: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/, enter the correct or updated information, and submit to the EHD for approval. <br /> This is a repeat violation, Class 11. <br /> FA0010744 PR0521131 SCO01 10/19/2022 <br /> EHD 19-01 Rev.12/06/2021 Page 2 of 5 Hazardous Materials Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />