My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3028
>
2800 - Aboveground Petroleum Storage Program
>
PR0530029
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 11:30:27 AM
Creation date
10/27/2022 9:31:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0530029
PE
2834
FACILITY_ID
FA0019299
FACILITY_NAME
PELICAN RENEWABLES LLC
STREET_NUMBER
3028
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
14502008
CURRENT_STATUS
01
SITE_LOCATION
3028 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J 0 A Q I I I Irl Environmental Health Department <br /> CCUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PELICAN RENEWABLES LLC 3028 NAVY DR, STOCKTON October 26, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 712 CFR 112.7(e), 112.8(c)(6) Failed to perform scheduled tank tests or inspections by appropriately qualified <br /> personnel. <br /> OBSERVATION: Facility failed to ensure that tanks are inspected and tested by an appropriately qualified person in <br /> accordance with industry standards. The tanks were not tested. Per the SPCC plan, monthly visual inspections of <br /> the tanks are to be done. No records of these inspections were available during the inspection. <br /> REGULATION GUIDANCE: 112.8(c)(6)Test or inspect each aboveground container for integrity on a regular <br /> schedule and whenever you make material repairs.You must determine, in accordance with industry standards,the <br /> appropriate qualifications for personnel performing tests and inspections, the frequency and type of testing and <br /> inspections,which take into account container size, configuration, and design (such as containers that are: <br /> shop-built,field-erected, skid-mounted, elevated, equipped with a liner, double-walled, or partially buried). Examples <br /> of these integrity tests include, but are not limited to:visual inspection, hydrostatic testing, radiographic testing, <br /> ultrasonic testing, acoustic emissions testing, or other systems of non-destructive testing.You must keep <br /> comparison records and you must also inspect the container's supports and foundations. In addition, you must <br /> frequently inspect the outside of the container for signs of deterioration,discharges, or accumulation of oil inside <br /> diked areas. Records of inspections and tests kept under usual and customary business practices satisfy the <br /> recordkeeping requirements of this paragraph. <br /> 112.7(e) Inspections,tests, and records. Conduct inspections and tests required by this part in accordance with <br /> written procedures that you or the certifying engineer develop for the facility. You must keep these written <br /> procedures and a record of the inspections and tests, signed by the appropriate supervisor or inspector,with the <br /> SPCC Plan for a period of three years. Records of inspections and tests kept under usual and customary business <br /> practices will suffice for purposes of this paragraph. <br /> CORRECTIVE ACTION: Immediately ensure that all tanks are inspected and tested by an appropriately qualified <br /> person in accordance with industry standards. Submit proof of correction/test results to the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. A complete report was <br /> finished on 11/9/2022 and replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: November 09, 2022 Inspector: Inspector Phone: <br /> Printed Name and Title: GABRIELA GARCIA-MEJIA, EH Specialist (209)616-3037 <br /> Emailed to Edker McCullough, Plant Manager <br /> FA0019299 PR0530029 SCO01 10/26/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 11 of 11 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.