Laserfiche WebLink
SHIELD EACH WAYINSULATIONWHERE REQUIREDROUND AND EXTENDED 2" BEYOND GALVANIZED INSULATION MAY BE HALF ROUND OR FULLSTRENGTH INSULATION AT EACH HANGER POINT.PROVIDE A SECTION OF HIGH COMPRESSIONPIPE(12" LONG)SHEET SHIELDGALVANIZED IRONNOTES:COPPER PIPE.2. PROVIDE COPPER OR PLASTIC COATED HANGERS FOR NON-INSULATED STRUCTURE TO THE TOP CHORD OF JOISTS OR BEAMS.1. ATTACH SUPPORTS FOR ALL PIPING SUSPENDED FROM THE STEEL FIN. FLOOR1/4 LEFT OPEN.METAL GRATE TOBE 3/4 WITHINSTALL FLUSH W/FINISHED FLOORFINISH FLOOR SLOPE TO DRAINADJUSTABLESTRAINERPRIMERTO TRAP1/2" CWOUTLETAND 4"Ø HOLESOUTLETCORE DRILL 10"Ø THREADED OR CAULKNOTE:FLOOR DRAINCAST IRONFLASHING SHALL BE FORMED TO CHIPPED CONCRETE WITH A POSITIVE SLOPE TO CLAMPDEVICE. PROVIDE NON- SHRINK SPOUT UNDER FLASHING AS REQUIRED TO FACILITATEPOSITIVE SLOPE. MINIMUM WIDTH OF FLASHING SHALL BE 24").PROOF MEMBRANE FLOOR AND BASE IN THE TOILET ROOM(S).THE GENERAL CONTRACTOR SHALL PROVIDE A ONE PIECE WATERBALL VALVEWALLGAS LINEFLEXIBLE HOSEGAS PIPEROOFROOF4"x4"x12" WOLMANIZED8"x18" RUBBERROOF MEMBRANEPAD OR MATCH LUMBER 8'-0" O.C.RESTRAINING CABLEFINISHED FLOORKITCHEN GASAPPLIANCECONNECTORSUPER SAFE GASQUICK DISCONNECT2-HOLE CLAMP(OVERSIZED 2 SIZES)NOTE: ROOF PAD IS RECOMMENDED TO AVOID ABRASION TO ROOFHANGER RODPLUGGED TEEWASTE OR VENTMAY EXTEND ASFLOOR LINEw/ CLEANOUTWASTE LINEWASTE LINELENGTH TO SUIT1/8 BENDPIPEINSULATIONSTONE BASE4"6"CHROME WALLCOVERAND SCREWCLEANOUT OCCURS1/8 BEND IFAT END OF LINEGROUND-JOINT PIPEUNIONSTEPPEDFLEXIBLE PVSBOOT CLAMPEDTO FLASHINGBASE AND PIPEWITH STAINLESSSTEEL SCREWCLAMPS.OR INSULATIONTOP OF DECKPROVIDE SPUNALUMINUM BASEIN BED OF MASTIC.COORDINATEWITH ROOFER.PIPE SLEEVEIF REQUIREDPIPEPIPE SUPPORT PERDETAILREFER TO PLANS FOR PIPE SIZES AND LOCATIONS. USE WELDED ORSCREWED FITTINGS AS SPECIFIED FOR PIPE SIZE, LOCATE PENETRATIONMINIMUM 18" FROM ADJECENT WALLS.ANCHOR PIPE TO ROOF DECK ORJOISTS WITH U-BOLT AROUND PIPEAND ANGLE IRON WELDED ORSCREWED TO DECK OR JOISTUNISTRUT CHANNELWHERE REQUIREDVENTTYPE 'L' COPPER LINEWITH WROUGHT COPPERFITTINGSRTUTYP.CURB1 1/2"6" MINDAIR SEAL P-TRAPDRAIN LINE SHALL BE AT LEAST THESAME SIZE AS THE NIPPLE ON THEDRAIN.CLEANOUT PLUG (THREADED)DNOTE: CONDENSATE DRAIN CONNECTION UP THRURTU CURB IS ACCEPTABLE.GAS CONNECTION DETAILSCALE: NO SCALEKITCHEN EQUIPMENTFLOOR SINK DETIALSCALE: NO SCALEGAS MOUNTING DETAILSCALE: NO SCALEFLOOR DRAIN w/TRAP PRIMERSCALE: NO SCALEROOF PENETRATION DETAILSCALE: NO SCALEWALL CEANOUT DETAILSCALE: NO SCALEPIPING DETAILSCALE: NO SCALERTU CONDENSATEVENT THRU ROOF DETAILSCALE: NO SCALEPIPE HANGER DETAILSCALE: NO SCALENOTE:1. ALL FLOOR SINKS MUST BE FLUSH WITH TILE FLOOR ASSHOWN ABOVE. INSTALLATION ON A 1/4" LIP EITHERDIRECTION IS ALSO ACCEPTABLE.P4DATEFOR PERMIT & BID01-25-22SEAL:PROJECT LOCATION:SHEET NUMBER:REVISION:DATE:CHECKED BY:ISSUE:DRAWN BY:PROJECT NO.:DATE:PROJECT INFORMATION:CLIENT:CONSULTANT:THESE DRAWINGS, IDEAS, SPECIFICATIONS ANDDESIGNS ARE EXCLUSIVE PROPERTY OF WINGSTOPRESTAURANTS, INC. NO PART OF THESE DRAWINGSMAY BE COPIED, REPRODUCED, OR OTHERSTRUCTURES BUILT FROM SUCH WITHOUT THEWRITTEN CONSENT OF WINGSTOP RESTAURANTS, INC.COPYRIGHT R 2022WINGSTOP RESTAURANTS, INC.ALL RIGHTS RESERVED15505 WRIGHT BROTHERS DRIVEADDISON, TX 75001TELEPHONE: (972) 686-6500FAX: (972) 686-6502DISCLAIMER:STOCKTON, CA2021-0486STORE NUMBER: GL#Z060 <br />GILL GROVE <br />1687 N CALIFORNIA STREET SUITE #TBD <br />STOCKTON, CA 95204JJVDRC2/3/22796 Merus Court <br />St. Louis, MO 63026 <br />T 636.349.1600 <br />F 636.349.1730TURN TRAP PRIMERDRAIN LINE INTOWALLALL EXPOSEDPIPING SHALLBE CHROMEPLATEDFLOOR DRAIN WITHTRAP PRIMERCONNECTIONTYPE 'K'COPPERTUBING - NOJOINTS BELOWFLOORRESTROOMLAVATORY ORSINKCOLD WATERKEEP MINIMUMSTOP VALVETRAP PRIMER WITHCHROME FINISH PPP#PRO1-ULP500 WITHDU-4TRAP PRIMER PIPING DETAILSCALE: NO SCALENOTE: FOR MULTIPLE DISTRIBUTION, CONTRACTOR MYSUBSTITUTE FOR #PRO1-500 IN LIEU OF SPECIFIED MODEL.REFER TO MANUFACTURE FOR INSTALLATION.REFER TOPLANSPLUMBING VENT STACKDRAWBANDINSTALL SEALANT BETWEEN PIPEAND PREFABRICATED MEMBRANEPREFABRICATED MEMBRANEFLASHING(8" MIN IN HEIGHT)SEALANT (PER SYSTEM)FLEECE BACKED MEMBRANESPRAY POLYURETHANE FOAMFOAM ADHESIVEROOF DECK- PREPARE ASREQUIRED.SEALANTSPRAY POLYURETHANE FOAM1" MIN. THICKNESSNOTE:SYSTEM IS TYPICAL. CONTRACTOR MAY MAKEADJUSTMENTS AS NECESSARY. SYSTEM SHALLBE WATER TIGHT AND MEET BUILDING CODESLOCAL AND STATE.