1A0.0NOT TO SCALELOCATION MAP2A0.0NOT TO SCALEKEY PLANPROJECT TEAMCODE INFORMATIONNORTHSHEET INDEXNOTESGENERALPROJECT COORD. NOTES1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL INSPECTIONS ANDAPPROVALS REQUIRED DURING THE COURSE OF THE WORK.2.ALL CONTRACTORS FOR THIS WORK ARE REQUIRED TO HAVE INSURANCE OF THETYPES AND LIMITS SPECIFIED BY THE LANDLORD AND BRAND PARTNER.3.IF REQUIRED BY LEASE AGREEMENT: THE GENERAL CONTRACTOR SHALL PROVIDESCHEDULING AND/OR COORDINATION WITH THE LANDLORD'S FIELD REPRESENTATIVEFOR THE FOLLOWING INSTALLATIONS OR PROCEDURES:A.INSTALLATIONS OF CONDUIT AND PIPING IN OR BELOW THE FLOOR SLAB.B.CONNECTIONS TO DOMESTIC WATER, SANITARY AND GREASE WASTE, SANITARY VENT,AND SMOKE/FIRE ALARM'S.C.INSTALLATION OF PRIMARY DUCTWORK, VAV BOX AND CONTROLS.D.PROGRAMMING OF THE VAV BOX CONTROL AND SENSORS.E.ANY WORK REQUIRED AT THE LANDLORD'S SWITCHGEAR.F. HARDWARE AND SOFTWARE MODIFICATIONS TO COMPLETE THE INTERFACE WITHLANDLORD'S BASE BUILDING LIFE SAFETY SYSTEM.G.UPON SUBSTANTIAL COMPLETION OF BRAND PARTNER'S WORK IN THE PREMISES,BRAND PARTNER AND HIS CONTRACTOR MUST SCHEDULE WITH THE LANDLORD'SFIELD REPRESENTATIVE TO CONDUCT A FINAL INSPECTION AND PREPARE APUNCHLIST WHICH ENUMERATES ANY AREAS OF CONSTRUCTIONS, FIXTURING,LIGHTING OR LAMPING, MERCHANDISING, ETC., THAT ARE NOT IN ACCORDANCE WITHTHE LANDLORD-APPROVED PLANS OR LEASE. THE STOREFRONT BARRICADE MAY NOTBE REMOVED UNTIL THIS INSPECTION AND ANY CORRECTIONS HAVE BEENCOMPLETED.H. LANDLORD'S CONDITIONS IN THE SHOPPING CENTER TENANT DESIGN GUIDEHANDBOOK SHALL BE PART OF ANY CONTRACT AND/OR AGREEMENT ENTERED INTOBY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL SCHEDULE APRE-CONSTRUCTION MEETING WITH THE ABOVE NOTED LANDLORD CONTACT PRIORTO ANY CONSTRUCTION.I. PROVIDE PROPERTY MANAGER REQUIRED PROOF OF BUILDER RISK INSURANCE ANDDAMAGE DEPOSIT PRIOR TO BEGINNING ANY DEMOLITION OR CONSTRUCTIONPROCEDURES.4. CONTRACTOR SHALL REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES,OR OMISSIONS HE MAY DISCOVER PRIOR TO COMMENCING WORK.5.DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS - DO NOT SCALE.6.ALL DIMENSIONS ARE FROM FACE OF SHEATHING UNLESS NOTED OTHERWISE.7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUPERVISING AND DIRECTING THEWORK USING HIS BEST SKILL AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLEFOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, ANDPROCEDURES. THE BRAND PARTNER RESERVES THE RIGHT TO ALLOW ASSIGNEDVENDORS IN CONNECTION WITH THE WORK. THE CONTRACTOR SHALL BE SOLELYRESPONSIBLE FOR COORDINATING THE WORK OF ALL SUBCONTRACTORS, INCLUDINGTHE VENDORS ASSIGNED BY THE BRAND PARTNER, WITH THE BRAND PARTNER. UPONREQUEST THE CONTRACTOR SHALL PROVIDE NECESSARY FIELD DIMENSIONS ANDINFORMATION TO ALL THE BRAND PARTNER ASSIGNED VENDORS AND/ORFABRICATORS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION,SCHEDULING, AND SUPERVISION OF ALL BRAND PARTNER SUPPLIED AND INSTALLEDITEMS.8. GENERAL CONTRACTOR TO COORDINATE LOCATION OF TRASH DUMPSTER WITHPROPERTY MANAGER.9. SAW CUTS: WHENEVER POSSIBLE ALL SAW CUTS SHALL BE LOCATED INSIDE THEPROPOSED COOKING AND SERVICE AREAS SCHEDULED FOR FLOOR TILE AND SHALLNOT OCCUR IN PROPOSED SEATING AREAS OR PASSAGEWAYS.10.PARTIAL PLANS: THE CONSTRUCTION DOCUMENTS AS DEFINED BY THE DRAWINGINDEX ARE ALL NECESSARY TO DEFINE THE TOTAL PROJECT. PARTIAL PLANS SHOULDNOT BE ISSUED BY THE BRAND PARTNER OR THE GENERAL CONTRACTOR FORBIDDING OR CONSTRUCTION.11.THE CONTRACTOR SHALL PROVIDE WOOD BLOCKING AS REQUIRED FOR MOUNTINGTABLES, SHELVING, CABINETS, AND ANY OTHER EQUIPMENT NOT SPECIFICALLYMENTIONED. ALL WOOD SHALL BE NON-COMBUSABLE AS PER LOCAL AUTHORITYHAVING JURISDICTION.12.EXISTING UTILITY SERVICES SHOWN TO REMAIN, REROUTE AS REQUIRED TO CONCEALTHE SERVICE IN WALLS AND ABOVE CEILING.13.TEMPORARY ENCLOSURES SHALL BE PROVIDED BY THE CONTRACTOR OVER AND/ORAROUND ANY EXTERIOR OPENINGS AS NECESSARY FOR THE PROPER INSTALLATIONOF ANY PORTION OF WORK IN CONJUNCTION WITH THE LANDLORD'S STANDARDGUIDELINES.14.GENERAL CONTRACTOR SHALL FURNISH AND INSTALL REQUIRED ROOF OPENINGFRAMING FOR SCHEDULED HVAC AND EXHAUST UNITS. FOR STRUCTURAL SUPPORTOF EQUIPMENT AND SUPPORT OF ROOF OPENINGS, REFER TO STRUCTURALDRAWINGS.15.GENERAL CONTRACTOR SHALL FURNISH AND INSTALL REQUIRED ROOFDOCUMENTATION FOR THE MODIFICATION OF EXISTING ROOF AS APPLICABLE PER THEBRAND PARTNER'S LEASE. THE LANDLORD SHALL BE CONTACTED TO OBTAIN ALLREQUIREMENTS FOR LISTED SUBCONTRACTORS WITH WARRANTY WORK FOR THESPECIFIED ROOFING SYSTEM.16.ALL Ix WOOD TRIM AS NOTED SHALL BE OF A CLEAR, MODIFY STAIN GRADE PINE.17.CONTRACTOR SHALL CONTACT THE LANDLORD DURING THE BIDDING PHASE OF THEPROJECT FOR ANY REQUIREMENTS FOR THE FIRE ALARM SYSTEMS. THESE SYSTEMS,IF REQUIRED, SHALL BE INCLUDED IN THE BID & CONSTRUCTION FOR THIS PROJECT.18.CONTRACT FORM:A.THE CONTRACT FORM SHALL BE A "STANDARD" FORM OF AGREEMENT BETWEENCONTRACTOR AND BRAND PARTNER OF THE CONSTRUCTION BUILDING'S A.I.A.DOCUMENT FORM A-101 CURRENT EDITION.B.GENERAL CONDITIONS OF THE CONTRACT: A.I.A. DOCUMENT A-201, GENERALCONDITIONS OF THE CONTRACT FOR CONSTRUCTION, 1997 EDITION, IS HEREBY MADEA REQUIREMENT OF THE CONTRACT DOCUMENTS. A COPY IS ON FILE WITH THEARCHITECT FOR THE CONTRACTOR TO REVIEW.20.SUBSTITUTIONS:A.NO MATERIAL SUBSTITUTIONS SHALL BE PERMITTED AFTER THE CONTRACTOR HASBEEN AWARDED JOB, SUBSTITUTIONS SHALL BE EQUAL OR BETTER IN THE OPINION OFTHE BRAND PARTNER PRIOR TO AWARD.B.SPECIFIED PRODUCTS HAVE BEEN USED IN PREPARING THESE DOCUMENTS TOESTABLISH MINIMUM QUALITIES WHICH SUBSTITUTIONS MUST MEET TO BECONSIDERED ACCEPTABLE. THE BURDEN OF PROOF OF EQUALITY RESTS WITH THECONTRACTOR. ADEQUATE SUPPORTING INFORMATION MUST ACCOMPANY ALLSUBSTITUTION SUBMITTALS, WHICH MUST BE SUBMITTED TO THE PROJECTCOORDINATOR FOR APPROVAL.21. MECHANICAL, ELECTRICAL AND PLUMBING:THE GENERAL CONTRACTOR SHALL FIELDVERIFY THE EXISTING UTILITIES FOR COORDINATION WITH THE MECHANICAL,ELECTRICAL, AND PLUMBING DRAWINGS PRIOR TO THE START OF WORK. THECONTRACTOR SHALL PROVIDE AN ALTERNATE BID TO REUSE EXISTING AIR HANDLERSAND COMPRESSORS OR ROOF-TOP PACKAGE UNITS. THE TOTAL HAVC LOAD SHALLMATCH THE SPECIFIED TOTAL LOAD ON THE MECHANICAL DRAWINGS. THECONTRACTOR SHALL CONTACT THE MECHANICAL ENGINEER WITH THE EXISTING LOADINFORMATION FOR APPROVAL.22. WINGSTOP STANDARDS: THE WINGSTOP STANDARD DESIGN, INCLUDING BUT NOTLIMITED TO: LIGHTING, SEATING, PAINT SELECTION, KITCHEN EQUIPMENT, FLOORING,WALL FINISHES, COUNTER HEIGHTS, SIGNAGE, AND ALL OTHER ELEMENTS AS NOTEDAND INCLUDED IN THESE CONTRACT DOCUMENTS ARE AS PER THE WINGSTOPRESTAURANT;S, INC. FRANCHISE AGREEMENT. ANY REVISIONS TO THESE DOCUMENTSOR FIELD CHANGES TO THIS DESIGN SHALL ONLY OCCUR UPON WRITTEN APPROVALSOF WINGSTOP RESTAURANTS, INC.23.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING THE EXTERIORGREASE INTERCEPTOR IN A MANNER THAT DOES NOT INTERFERE WITH ANY EXISTINGSETBACKS, EASEMENTS, UNDERGROUND UTILITIES, OR OTHER SITE FEATURES.24.THE HOOD AND WALK-IN COOLER/FREEZER SUPPLIER SHALL SUBMIT SHOP DRAWINGSTO WINGSTOP RESTAURANTS, INC. FOR REVIEW PRIOR TO FABRICATION.25.THE GENERAL CONTRACTOR SHALL VERFIY FIELD CONDITIONS FOR THE HOODEXHAUST DUCT AND WALK-IN COOLER/FREEZER AND COORDINATE WITH THE KITCHENEQUIPMENT SUPPLIER PRIOR TO FABRICATION ND INSTALLATION.1.ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH FEDERAL, STATE, ANDLOCAL CODE ORDINANCES AND LAWS.2.THE CONTRACTOR SHALL VISIT THE JOB SITE, VERIFY EXISTING CONDITIONS,AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO SUBMITTING ABID AND/OR BEGINNING ANY CONSTRUCTION WORK.3.ALL WORK, WHEN COMPLETED, SHALL CONFORM TO THE GOVERNINGJURISDICTIONAL ACCESSIBILITY STANDARDS.4.THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIESFOUND BETWEEN THE CONTRACT DOCUMENTS FOR RESOLUTION.5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING A COMPLETEAS-BUILT SET OF CONSTRUCTION DRAWINGS AT THE JOB SITE AND TURNINGTHE AS-BUILT DRAWINGS OVER TO THE OWNER UPON COMPLETION OF THEPROJECT.6.REFER TO INDIVIDUAL DRAWINGS WITHIN THIS SET OF CONSTRUCTIONDOCUMENTS FOR ADDITIONAL GENERAL NOTES.7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THOROUGHLY CLEANING THECOMPLETED JOB SITE PRIOR TO TURNING THE PROPERTY OVER TO THE OWNERFOR OCCUPANCY.8.IN THE EVENT THAT THE CONTRACTOR, OR SUBCONTRACTOR AT ANY TIER,DETERMINES THAT SOME PORTION OF THE DRAWINGS, SPECIFICATIONS, OROTHER CONTRACT DOCUMENTS REQUIRES CLARIFICATION OR INTERPRETATIONBY THE ARCHITECT, THE CONTRACTOR SHALL SUBMIT A REQUEST FORINFORMATION IN WRITING TO THE ARCHITECT.9.REQUESTS FOR INFORMATION MAY ONLY BE MADE BY THE GENERALCONTRACTOR. THE CONTRACTOR SHALL CLEARLY AND CONCISELY SET FORTHTHE ISSUE FOR WHICH CLARIFICATION IS SOUGHT AND WHY A RESPONSE ISNEEDED FROM THE ARCHITECT AND/OR CONSULTANTS. IN THE REQUEST FORINFORMATION, THE CONTRACTOR SHALL SET FORTH AN UNDERSTANDING OFTHE REQUIREMENT, ALONG WITH A REASON WHY SUCH AN UNDERSTANDINGWAS REACHED. THE ARCHITECT WILL REVIEW THE REQUEST FOR INFORMATIONTO DETERMINE IF IT IS A REQUEST FOR INFORMATION WITHIN THE MEANING OFTHIS TERM. IF THE ARCHITECT DETERMINES THAT IT IS NOT A REQUEST FORINFORMATION, IT WILL BE RETURNED TO THE CONTRACTOR, UNREVIEWED AS TOCONTENT, FOR RESUBMITTAL IN THE PROPER FORM AND THE PROPER MANNER.10.RESPONSES TO REQUESTS FOR INFORMATION SHALL BE ISSUED UPON RECEIPT,BUT NO LATER THAN FIVE WORKING DAYS OF RECEIPT OF THE REQUEST,UNLESS THE ARCHITECT DETERMINES THAT A LONGER PERIOD OF TIME ISNEEDED IN ORDER TO PROVIDE AN ADEQUATE RESPONSE. IF A LONGER PERIODOF TIME IS DETERMINED NECESSARY BY THE ARCHITECT, THE ARCHITECT WILL,WITHIN FIVE WORKING DAYS OF THE RECEIPT OF THE REQUEST FORINFORMATION, NOTIFY THE CONTRACTOR OF THE ANTICIPATED RESPONSE TIME.11.IF THE CONTRACTOR SUBMITS A REQUEST FOR INFORMATION WITH FIVEWORKING DAYS OR LESS FLOAT ON THE CURRENT PROJECT SCHEDULE, THECONTRACTOR SHALL NOT BE ENTITLED TO ANY TIME EXTENSION DUE TO THETIME IT TAKES THE ARCHITECT TO RESPOND TO THE REQUEST FORINFORMATION, PROVIDED A RESPONSE IS GIVEN WITHIN FIVE WORKING DAYS ASSET FORTH ABOVE.12.RESPONSES FROM THE ARCHITECT WILL NOT CHANGE ANY REQUIREMENTS OFTHE CONTRACTOR DOCUMENTS. IN THE EVENT THAT THE CONTRACTORBELIEVES A RESPONSE TO A REQUEST FOR INFORMATION WILL CAUSE ACHANGE TO REQUIREMENTS OF THE CONTRACT DOCUMENTS, THECONTRACTOR SHALL IMMEDIATELY GIVE WRITTEN NOTICE TO THE ARCHITECTAND THE OWNER STATING THAT THE CONTRACTOR CONSIDERS THE RESPONSETO BE A CHANGE ORDER. FAILURE TO GIVE SUCH WRITTEN NOTICEIMMEDIATELY SHALL WAIVE THE CONTRACTOR'S RIGHT TO SEEK ADDITIONALTIME OR COST.13.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR ANDUNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES(POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES,METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THECONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWERLINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURETO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONALEXPENSES.14.PROVIDE ULTRA FLUSH WATER CLOSETS OR ALL NEW CONSTRUCTION. EXISTINGPOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATERCONSUMPTION.15.A COPY OF THE VALID EVALUATION REPORT AND/OR CONDITIONS OF LISTINGSHALL BE MADE AVAILABLE AT THE JOB SITE.16.OBTAIN SEPARATE PERMIT FOR RETAINING WALLS OR BLOCK FENCE WALLS,GRADING WORK, ELECTRICAL, PLUMBING, AND SIGNAGE.SYMBOLS LEGEND00A0.000A0.000A0.00010000ROOMNAME000000ASTRUCTURALGRIDBUBBLEENLARGEDDRAWINGBUBBLEELEVATIONMARKERSECTIONMARKERWALL TYPEMARKERREVISIONMARKEREQUIPMENTMARKERACCESSIBLEPATH OFTRAVELKEYED NOTEMARKERROOM NAME/NUMBERDOOR /WINDOWNUMBERMATERIALMARKER00NOTES TO BIDDERSARCHITECTURAL FLOOR PLANA1.0A1.1A2.0A3.121SHEET INDEXFINISH, DOOR, & HARDWARE SCHEDULESA4.0SALES COUNTER PLAN & DETAILSA5.0WALL SECTIONS & DETAILSA6.0EQUIPMENT PLANEQ1INTERIOR EQUIPMENT ELEVATIONSEQ2MECHANICAL PLANM1MECHANICAL DETAILS / SCHEDULESM2MECHANICAL SPECIFICATIONSM3SANITARY PLANP1WATER & GAS PLANP2RISER DIAGRAMSP3LIGHTING PLANE1E2E3POWER PLANELECTRICAL SPECIFICATIONSSHEET DESCRIPTIONFLOOR FINISH PLAN & DETAILSREFLECTED CEILING PLAN & DETAILSDECOR ELEVATIONSARCHITECTURALKITCHEN EQUIPMENTMECHANICALELECTRICALPLUMBINGSTRUCTURALA0.0B1.0INTERIOR ACCESSIBILITYB2.0ACCESSIBILITY & ENLARGED RESTROOM PLANHOOD DRAWINGSH1H2H3H4HOOD DRAWINGSHOOD DRAWINGSHOOD DRAWINGSH5HOOD DRAWINGSMECHANICAL SPECIFICATIONSM4PLUMBING DETAILSP4PLUMBING SPECIFICATIONSP5LANDLORD / LESSOR:BRAND PARTNER / OWNERARCHITECTPROJECT COORDINATORSTRUCTURAL ENGINEERM.E.P. ENGINEERWINGS R US, LLC1063 CHESHIRE CIRCLEDANVILLE, CA 94506PHONE NO.: (925) 260-3605EMAIL:rb@fpfginc.comATTN:Ranjan BhasinWINGSTOP RESTAURANTS, INC15505 WRIGHT BROTHERS DRIVEADDISON, TX 75001PHONE NO.: (972) 686-6500 FAX NO.: (972) 686-6502ATTN: TODD BRINJASBIR S. GILL, FAMILY LIMITED PARTNERSHIP III, LPC/O BLR COMMERCIAL REAL ESTATE, INC.2291 WEST MARCH LANE, SUITE B-215STOCKTON, CA 95207PHONE NO.: (209) 475-1980WINGSTOPWINGSTOPNORTHNORTHPLANWILKUS ARCHITECTS, P.A.15 NINTH AVENUE NORTHHOPKINS, MINNESOTA 55343PHONE NO.: (952) 941-8660FAX NO.: (952) 941-2755ATTN: JIM SULTANYCASE ENGINEERING, INC.796 MERUS COURTFENTON, MO 63026PHONE NO.: (636) 349-1600FAX NO.: (636) 349-1730 ATTN: NICK BASLERCASE ENGINEERING, INC.796 MERUS COURTFENTON, MO 63026PHONE NO.: (636) 349-1600FAX NO.: (636) 349-1730ATTN: KYLE WOODARDSTOCKTON, CA (GL#Z060)DECORMARKERA3.0INTERIOR ELEVATIONSEQUIPMENT DATA ELEVATIONSEQ3GENERAL NOTES, PLAN, AND DETAILSS1EXISTING ROOF FRAMING PLANS2TRUETRUEB1.1ACCESSIBILITY NOTESB1.2SITE ACCESSIBILITY PLAN AND DETAILSFIRE DEPARTMENT1. ALL LIFE-SAFETY SYSTEMS SHALL BE DESIGNED PER APPLICABLE FIREPREVENTION CODE.2. FIRE EXTINGUISHER REQUIREMENTS SHALL BE AS DETERMINED BY FIELDINSPECTION AND NFPA 10. THE CONTRACTOR SHALL SUPPLY ALL FIREEXTINGUISHERS.3. BUILDING ADDRESS NUMBERS SHALL BE PROVIDED ON THE FRONT OF THEBUILDING AND SHALL BE VISIBLE AND LEGIBLE FROM THE PUBLIC RIGHT-OF-WAY,SAID NUMBERS SHALL CONTRAST VISUALLY WITH THEIR BACKGROUND.ADDRESS NUMBERS SHALL BE PROVIDED BY THE CONTRACTOR.4. POST "NO PARKING - FIRE LANE" SIGNS ALONG VEHICULAR ACCESS ROADS.5. IF REQUIRED - ENGINEERED AUTOMATIC FIRE SPRINKLER SYSTEM DRAWINGSAND CALCULATIONS SHALL BE DESIGNED AND SUBMITTED BY AN APPROVEDINSTALLER PRIOR TO INSTALLATION.6. THE INSPECTION, HYDROSTATIC TESTING, AND FLUSHING OF THE AUTOMATICFIRE SPRINKLER SYSTEM AND/OR FIRE HYDRANTS SHALL BE WITNESSED BY THEPROPER FIRE DEPARTMENT REPRESENTATIVE AND NO UNDERGROUND PIPINGSHALL BE COVERED OR HIDDEN FROM VIEW UNTIL THE PROPER FIREDEPARTMENT REPRESENTATIVE HAS BEEN NOTIFIED AND GIVEN NO LESS THANFORTY-EIGHT HOURS IN WHICH TO INSPECT SUCH INSTALLATIONS.1. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING THE EXTERIORGREASE INTERCEPTOR AND MUST FIELD VERIFY ALL SITE CONDITIONS DURING THEBIDDING PHASE OF THE PROJECT AND ASSIGN ALL APPLICABLE COSTS. THE LOCATIONSHALL NOT INTERFERE WITH ANY EXISTING SETBACKS, EASEMENTS, UNDERGROUNDUTILITIES, OR OTHER SITE FEATURES.2. IF REQUIRED, THE GENERAL CONTRACTOR SHALL PROVIDE ENGINEERED AUTOMATICFIRE SPRINKLER SYSTEM DRAWINGS AND CALCULATIONS, DESIGNED AND SUBMITTEDBY AN APPROVED INSTALLER PRIOR TO INSTALLATION.MECHANICAL SPECIFICATIONSM5MECHANICAL SPECIFICATIONSM6MECHANICAL SPECIFICATIONSM7E4ELECTRICAL SPECIFICATIONSSEAL:STORE NUMBER: GL#Z060
<br />GILL GROVE
<br />1687 N CALIFORNIA STREET SUITE #TBD
<br />STOCKTON, CA 95204PROJECT LOCATION:SHEET NUMBER / TITLE:REVISION:DATE:CHECKED BY:ISSUE:DRAWN BY:PROJECT NO.:DATE:PROJECT INFORMATION:CLIENT:CONSULTANT:STOCKTON, CAXXXJSS2021-0486THESE DRAWINGS, IDEAS, SPECIFICATIONS ANDDESIGNS ARE EXCLUSIVE PROPERTY OF WINGSTOPRESTAURANTS, INC. NO PART OF THESE DRAWINGSMAY BE COPIED, REPRODUCED, OR OTHERSTRUCTURES BUILT FROM SUCH WITHOUT THEWRITTEN CONSENT OF WINGSTOP RESTAURANTS, INC.COPYRIGHT R 2013WINGSTOP RESTAURANTS, INC.ALL RIGHTS RESERVED15505 WRIGHT BROTHERS DRIVEADDISON, TX 75001TELEPHONE: (972) 686-6500FAX: (972) 686-6502DISCLAIMER:PERMIT & BID SET01-25-22DATE01-25-22EXPIRATION DATE: 06-30-2023MATTHEW M. WILKUS, ARCHITECTLICENSE NUMBER: C-37430A0.0San Joaquin County Environmental Health Department 1868 E. Hazelton Ave. Stockton, CA 95205 (209) 468-3420 APPROVED WITH CONDITIONS For conditions, please see approval letter dated: Approved by:_______________________Date:_______________ 2-24-22Feb 24, 2022 Daria Afonskaia
|