22'-3"50'-5 3/4"1A1.01/4" = 1'-0"ARCHITECTURAL FLOOR PLANNORTHPLAN1. REFER TO SHEET EQ1 FOR SEATING, AND EQUIPMENT LAYOUT ANDSHEET EQ2 FOR EQUIPMENT ELEVATIONS.2. DIMENSIONS ARE TO THE FINISH FACE OF SHEATHING.3. REFER TO THE PLUMBING DRAWINGS FOR ALL FLOOR SINK ANDFLOOR DRAIN LOCATIONS.4. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED.5. EXIT SIGNS ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE ANINTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54 LUX)6. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED ANDSHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’SINSTRUCTIONS AND SECTION 2702.7. EXIT SIGNS SHALL BE ILLUMINATED ALL TIMES8. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEMTHAT WILL PROVIDE AN ILLUMINATION OF NOT LESS THAN 90 MIN. INCASE OF PRIMARY POWER LOSS (1011.2-1011.5.3)9. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESSSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OREFFORT. SEE 1008.1.8.3 FOR EXCEPTIONS.10. DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BEINSTALLED AT A MIN. 34” AND A MAX 48” ABOVE THE FINISHED FLOOR.11. THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED12. ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITHSECTION 1008.1.9 – 1008.1.9.713. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BEILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THEMEANS OF EGRESS IS OCCUPIED.14. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESSTHAN 1 FOOT-CANDLE AT THE WALKING SURFACEFLOOR PLAN NOTES50'-5 3/4" <br />VERIFY IN FIELD - NOTIFY ARCHITECT OF ANY DISCREPANCIES <br />21'-11 3/8"VERIFY IN FIELD - NOTIFY ARCHITECT OF ANY DISCREPANCIES104A3.06798ORDER101COOKING105PREP106JANITOR107COOLER108FREEZER109NOTE:REFER TO A0.0 FOR GENERAL NOTESAND NOTES TO BIDDERSNORTHTRUE2'-4 7/8"11'-0"A3.01243UNISEX110SALES1041101011A5.02455556622222225553333311333119'-11"7'-5 3/8"18'-4 3/8"8'-0 1/8"18'-11 3/8"18'-11 3/8"4'-0 1/2"11'-9 1/2"6'-11"6'-5 1/4"3'-4 3/8"2 7/8"7'-10 1/8"3'-0"5'-10 1/4" <br />7'-10 1/8"3'-0"5'-10 1/4" <br />3'-1 1/4"3'-4"3'-3" <br />9'-4 1/2"1'-1"16'-7 1/4"1'-1"8'-0"1'-0 5/8"1'-0"5'-0"2'-10 3/4"5'-1 3/4"1'-9 1/4"1'-6"1'-7 1/4"CLCLCL CL6" MIN.FLOOR PLAN LEGENDDASHED LINE INDICATES EXHAUST HOOD - REFER TO REFLECTEDCEILING PLAN ON SHEET A2.0 FOR ADDITIONAL INFORMATION.NOT USEDEXIST. THRESHOLD TO REMAIN - VERIFY 1/2" LIP MAXIMUM ANDBEVELED SIDES THAT SLOPE 1:2 MAXIMUM - REPLACE AS NEEDED.DASHED LINE INDICATES SOFFIT / HEADER ABOVE - REFER TOREFLECTED CEILING PLAN ON SHEET A2.0.ELECTRICAL PANEL LOCATION - PROVIDE A 30" X 36" CLEAR FLOORSPACE IN FRONT OF PANEL(S) - REFER TO ELECTRICAL DRAWINGSFOR ADDITIONAL INFORMATION.123456NOT USED7NOT USED1. REFER TO SHEET EQ1 FOR SEATING, AND EQUIPMENT LAYOUT ANDSHEET EQ2 FOR EQUIPMENT ELEVATIONS.2. DIMENSIONS ARE TO THE FINISH FACE OF SHEATHING.3. VERIFY DEMISING WALLS ARE FULL HEIGHT TO DECK - NOTIFYARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION.FLOOR PLAN NOTES15.THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALLNORMALLY BE PROVIDED BY THE PREMISES’ ELECTRICAL SUPPLY. INTHE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICALSYSTEM SHALL AUTOMATICALLY ILLUMINATE THE FOLLOWING AREAS;A) AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMSAND SPACES THAT REQUIRE TWO OR MORE MEANS OF EGRESS;B)CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYSIN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS;C)EXTERIOR EGRESS COMPONENTS AT OTHER THAN THELEVEL OF EXIT DISCHARGE UNTIL EXIT DISCHARGE ISACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO ORMORE EXITS;D)INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED INSECTION 1027.1., IN BUILDINGS REQUIRED TO HAVE TWO ORMORE EXITS;E)EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1008.1.5,FOR EXIT DISCHARGE DOORWAYS IN BUILDINGS REQUIRED TOHAVE TWO OR MORE EXITS.16.THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FORDURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OFSTORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR.THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE INACCORDANCE WITH SECTION 2702.17.EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDEINITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1FOOT-CANDLE (11 LUX) AND A MINIMUM AT ANY POINT OF 0.1FOOT-CANDLE (1 LUX) MEASURED ALONG A PATH OF EGRESS ATFLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TODECLINE TO 0.6 FOOT-CANDLE (6 LUX) AVERAGE AND A MINIMUM ATANY POINT OF 0.06 FOOT-CANDLE (0.6 LUX) AT THE END OF THEEMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUMILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BEEXCEEDED.FLOOR PLAN NOTES CONT.8REPLACE EXISTING GLAZING WITH OPAQUE SPANDREL GLASS -OBTAIN APPROVAL FROM LANDLORD BEFORE PROVIDING ANDINSTALLING.888884EL GRULLITO - 'B' OCCUPANCY <br />VACANT - 'B' OCCUPANCY21022A5.0V.I.F.4 7/8"3EXISTING DEMISING WALL TO REMAIN (WALL CONSTRUCTION VARIES)FIELD VERIFY EXIST. CONDITIONS & REPAIR AS REQUIRED* REFER TO 2/A1.0 FOR SHEATHING MODIFICATION WITH WATERPROOFING @ ALL WETAREASEXISTING WALL TO REMAIN (WALL CONSTRUCTION VARIES)FIELD VERIFY EXIST. CONDITIONS & REPAIR AS REQUIRED* REFER TO 2/A1.0 FOR SHEATHING MODIFICATION WITH WATERPROOFING @ ALL WETAREASWALL #1 <br />1WALL #2 <br />25/8" TYPE 'X' GYP. BD.3 5/8" 25 GA. MTL. STUDS (DIETRICH, ICC/ESR 2457) @ 24" O.C.5/8" TYPE 'X' GYP. BD.* BRACE TO STRUCTURE PER DETAIL 1/A6.0* REFER TO 2/A1.0 FOR SHEATHING MODIFICATION WITH WATERPROOFING @ ALL WETAREASWALL #3V.I.F.WALL LEGENDNEW KNEE WALLSNEW PARTITIONSEXIST. WALLS, OR PARTITIONSWALL TYPES4WALL #4 <br />57 1/4"5/8" TYPE 'X' GYP. BD.6" 20 GA. MTL. STUDS (DIETRICH, ICC/ESR 2457) @ 16" O.C.5/8" TYPE 'X' GYP. BD.* BRACE TO STRUCTURE PER DETAIL 1/A6.0* REFER TO 2/A1.0 FOR SHEATHING MODIFICATION WITH WATERPROOFING @ ALL WETAREASWALL #5- PROVIDE MOISTURE RESISTANT GYP. BD. AT WET AREAS- INSTALL GYP. BD. CONTROL JOINTS AS NEEDED TO PREVENT CRACKING- PROVIDE FINISHES PER ROOM FINISH SCHEDULE ON SHEET A4.0EXISTING WALL AND STOREFRONT TO REMAIN (WALL CONSTRUCTION VARIES)FIELD VERIFY EXIST. CONDITIONS & REPAIR AS REQUIREDADD 1 5/8" 25 GA. MTL. STUDS (DIETRICH, ICC/ESR 2457) @ 24" O.C.ADD 5/8" TYPE 'X' GYP. BD.* FACE OF GYP. BD. TO BE FLUSH WITH ADJACENT WALL TYPE #1* REFER TO 3/A1.0 FOR SHEATHING MODIFICATION WITH WATERPROOFINGV.I.F.2 1/4"1'-0"48"1'-0"6"3A1.0NOT USED2A1.03" = 1'-0"TYPICAL SHEATHING MODIFICATIONSCHEDULED DEMISING WALL -REFER TO WALL SCHEDULE5/8" MOISTURE RESISTANT(MR) TYPE 'X' GYP. BD. TO 48"A.F.F.5/8" CEMENT BOARD TO 12"A.F.F.REFER TO FINISH SCHEDULEON SHEET A3.0EXISTING SLABINTEGRAL COVED BASECONT. ELASTOMETRICWATERPROOFING MEMBRANE- APPLY TO CEMENT BOARDWALL & CONC. FLOORSEAL - CONT. BEAD SILICONEA1.0ARCHITECTURAL FLOOR PLANSEAL:STORE NUMBER: GL#Z060 <br />GILL GROVE <br />1687 N CALIFORNIA STREET SUITE #TBD <br />STOCKTON, CA 95204PROJECT LOCATION:SHEET NUMBER / TITLE:REVISION:DATE:CHECKED BY:ISSUE:DRAWN BY:PROJECT NO.:DATE:PROJECT INFORMATION:CLIENT:CONSULTANT:STOCKTON, CAXXXJSS2021-0486THESE DRAWINGS, IDEAS, SPECIFICATIONS ANDDESIGNS ARE EXCLUSIVE PROPERTY OF WINGSTOPRESTAURANTS, INC. NO PART OF THESE DRAWINGSMAY BE COPIED, REPRODUCED, OR OTHERSTRUCTURES BUILT FROM SUCH WITHOUT THEWRITTEN CONSENT OF WINGSTOP RESTAURANTS, INC.COPYRIGHT R 2013WINGSTOP RESTAURANTS, INC.ALL RIGHTS RESERVED15505 WRIGHT BROTHERS DRIVEADDISON, TX 75001TELEPHONE: (972) 686-6500FAX: (972) 686-6502DISCLAIMER:PERMIT & BID SET01-25-22DATE01-25-22EXPIRATION DATE: 06-30-2023MATTHEW M. WILKUS, ARCHITECTLICENSE NUMBER: C-37430