Laserfiche WebLink
MONITORING AND REPORTING PROGRAM ORDER NO. R5-2015-0012 2 <br /> HUMAN SERVICES AGENCY, 145 SOUTH SUTTER STREET, STOCKTON, CA 95202 <br /> IN-SITU REMEDIATION OF PETROLEUM HYDROCARBONS <br /> SAN JOAQUIN COUNTY <br /> Table 1: Sampling Frequency and Constituent Suite <br /> Well Number' Constituent Suites Frequency' Monitoring Objective <br /> Baseline (prior to injection), <br /> Suite A and Field three, six, and twelve months Treatment Zone3 <br /> Sampling after injection. Semiannual <br /> MW-2 thereafter. <br /> Suite B and Field Baseline (prior to injection), <br /> Sampling six, and twelve months after Treatment Zone3 <br /> injection. Annual thereafter. <br /> Baseline (prior to injection), <br /> Suite A and Field three, six, and twelve months Treatment Zone3 <br /> Sampling after injection. Semiannual <br /> MW-10 5 thereafter. <br /> Suite B and Field Baseline (prior to injection), <br /> Sampling six, and twelve months after Treatment Zone3 <br /> injection. Annual thereafter. <br /> Baseline (prior to injection), <br /> Suite A and Field six, and twelve months after Compliance' <br /> Sampling injection. Semiannual <br /> MW-6 thereafter. <br /> Suite B and Field Baseline (prior to injection), <br /> Sampling and twelve months after Compliance' <br /> injection. Annual thereafter. <br /> Baseline (prior to injection), <br /> Suite A and Field six, and twelve months after Compliance' <br /> Sampling injection. Semiannual <br /> MW-7 thereafter. <br /> Suite B and Field Baseline (prior to injection), a <br /> Sampling and twelve months after Compliance <br /> injection. Annual thereafter. <br /> Suite B and Field Baseline (prior to injection), <br /> MW-3A Sampling three, six, and twelve months Background' <br /> after injection. <br /> Suite B and Field Baseline (prior to injection), <br /> MW-g Sampling three, six, and twelve months Background' <br /> after injection. <br /> ' Well numbers and locations as shown on Figure 1. <br /> 2 Constituent suite components and analytical methods are listed in Table 2. <br /> 3 Wells sampled to evaluate in-situ bioremediation progress inside the treatment zone. <br /> 4 Wells used to determine compliance with water groundwater limitations. <br /> 5 Well MW-10 is characterized as Treatment Zone well because it lies within the injection area. However, well <br /> MW-10 is screened in deeper zone (93.5 to 103.5 feet bgs)compared to MW-2, which is screened in shallow <br /> zone (30 to 45 feet bgs). <br /> 6 Wells used to develop background concentrations. <br />