WWWWWWMON
<br />I
<br />TOR
<br />IN
<br />G
<br />/OBSERV
<br />AT
<br />IO
<br />N W
<br />EL
<br />L
<br />DO NO
<br />T
<br /> F
<br />IL
<br />L
<br />MONITO
<br />R
<br />ING
<br />
<br />/
<br />OBSER
<br />VA
<br />TI
<br />ON
<br /> WE
<br />LLDO NOT
<br /> F
<br />I
<br />LL
<br />NOPARKINGEV CHARGINGONLYNOPARKINGNOPARKING18'-0"25'-6"5'45'-0"
<br />CANOPY
<br />5'-6"65'-10"90'-5"67'-6"7'-1"10'-8"64'-10"44'-5"8'-4"
<br />7'-11"55'-8"132'-0"CANOPY8'-0"17'-3"12'-0"118'-0"±17'-6"LIMIT OF WORKLIMIT OF WORK
<br />LIMIT OF WORK>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
<br />>>>>>>>>
<br />>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>1SITE PLANSCALE: 1" = 20'-0"CANOPY4,320 S.F.C-STORE3,000 S.F.FUEL 11.EXIST. PROPERTY LINE. (TYP).2.EXIST. CURB, GUTTER AND SIDEWALK TO REMAIN. (TYP.).3.EXIST. ENTRANCE DRIVE TO REMAIN.4.EXIST. SIDEWALK TO REMAIN. A.D.A. COMPLIANT PATH OFTRAVEL TO ADJOINING PARCELS. (TYP.).5.EXIST. A.D.A. COMPLIANT CURB RAMP BY OTHERS.6.NEW A.D.A. COMPLIANT CONC. CURB RAMP.7.WHEEL STOP. RE: CIVIL DWGS.8.6" CONC. CURB BY G.C., RE: CIVIL DWGS. (TYP.)9.ELECTRIC VEHICLE CHARGING STALL. PROVIDE LEVELSURFACE WITH MAX. 2% CROSS SLOPE AT EVCS STALL ANDACCESSIBLE AISLE.10.6" CONC. DRIVE SLAB WITH #3 REBAR 18" O.C. BOTH WAYS.11.DRAIN LINE FROM CANOPY STRUCTURE ROOF TOP, RE:CIVIL DWGS.12.8" THICK CONC. TANK SLAB WITH #3 REBAR 12" O.C. BOTHWAYS . SEE FUEL DWGS.13.UNDERGROUND DOUBLE WALL FUEL TANKS, RE FUEL DWGS.14.FUEL TANK VENTS WITH STEEL FRAME, RE: FUEL DWGS.15.WALL OR COLUMN MOUNTED EMERGENCY FUEL SHUT-OFFPUSH BUTTON SWITCH AND SIGNAGE. LOCATE SWITCH ATMAX. 44" ABOVE FINISHED GRADE OR FINISHED ASPHALTSURFACE. RE: FUEL DWGS.16.FUEL DISPENSING AND ASSOCIATED EQUIPMENT LOCATEDUNDER FUEL CANOPY, RE: SHEET AC-1.17.ASPHALT PAVING ATOP COMPACTED FILL, RE: CIVIL DWGS.18.TREE WELL. RE: LANDSCAPE DWGS.19.LANDSCAPE AREA RE: LANDSCAPE DWGS.20.STANDARD PARKING STALL WITH STRIPING ATOP ASPHALTPAVING, USE TRAFFIC RATED PAINT, MIN. (2) COATS.21.A.D.A. COMPLIANT PARKING STALL WITH STRIPING ATOPASPHALT PAVING, USE TRAFFIC RATED PAINT, MIN. (2)COATS, RE: G1.0. PROVIDE LEVEL SURFACE WITH MAX. 2%CROSS SLOPE AT ADA PARKING STALL AND ACCESSIBLEAISLE.22.A.D.A. COMPLIANT PARKING SIGNAGE.23.6" DIA. X 42" H. CONC. PIPE BOLLARD @ 5' O.C. TYP. BOLLARDTO BE COVERED WITH SAFETY SLEEVE. SLEEVE FURN. BYG.C. AND INSTALLED BY G.C. RE:12/AS7.1.24.MASONRY TRASH ENCLOSURE WITH STEEL GATES. RE:AS4.1 AND STRUCTURAL.25.AIR STATION VENDING EQUIPMENT ATOP CONC. SLAB.26.NEW LIGHT POLE AND CONC. BASE.27.EV CHARGING STATION.28.SLOPED CONC. SIDEWALK ATOP COMPACTED FILL, MAINTAINA.D.A. COMPLIANT PATH OF TRAVEL FOR EXITING PURPOSESFROM C-STORE, MAX. CROSS SLOPE 2%, RE: CIVIL ANDLANDSCAPE DWGS.29.GAS METER, RE: P-SERIES SHEETS .30.DOMESTIC WATER METER AND PIPING, RE: P- SERIESSHEETS AND CIVIL.31.LOCATION OF SEWER STUB, EXTEND TO BLDG. RE: P-SERIESSHEETS AND CIVIL32.LOCATION OF ELECT. XFMER, RE: E-SERIES SHEETS.33.LOCATION OF ELECTRIC METER EQUIPMENT, PAINT TOMATCH ADJACENT BUILDING WALL COLOR, RE: E-SERIESSHEETS .34.LOCATION OF UNDERGROUND WATER PROOF FIBER OPTICBOX.35.DASHED LINE INDICATING FUEL CANOPY, RE: CANOPYDWGS.36.LOCATION OF FUEL MONUMENT SIGN STRUCTURE, G.C.SHALL PROVIDE (2) 2" CONDUITS, WATER PROOF J-BOXES,AND PULL STRING TO SOURCE OF ELECTRICAL POWER,WIRE PULL AND FINAL CONNECTION OF SIGN, AND SIGNCIRCUIT TO ELECTRIC SERVICE PANEL BY SIGNCONTRACTOR. NOTE SIGN NOT A APART OF THIS PERMIT.LOCATION SHOWN FOR COORDINATION OF G.C.'SELECTRICAL SCOPE OF WORK.37.LOCATION OF UNDERGROUND CONDUIT FOR FUEL /MONUMENT SIGNAGE, RE: E-SERIES SHEETS.38.LOCATION OF UNDERGROUND CONDUIT FOR POWER TO AIRSTATION, RE: E-SERIES SHEETS.39.LOCATION OF UNDERGROUND CONDUIT FOR POWER TO EVCHARGER, RE: E-SERIES SHEETS.40.REMOTE CO2 FILL, RE: FLOOR PLAN.41.BICYCLE PARKING LOOP, RE: SITE DETAIL SHEET.42.2" DIA CONDUITS / COMMUNICATIONS FEED AT CANOPY, RE:FUEL & ELECT. DWGS. NOTE: G.C. TO FURN. WATERPROOFJ-BOX, CONDUIT, PULL STRING AND TRENCHING FORINSTALLATION OF ELECTRICAL COMPONENTS, FINALEQUIPMENT CABLING BY ABSCO VENDOR.43.SEWER LINE TO TRASH ENCLOSURE. RE: CIVIL.44.NEW DRAINAGE STRUCTURE. RE: CIVIL DWGS.45.EXISTING DRAINAGE STRUCTURE. RE: CIVIL DWGS.46.NEW TRENCH DRAIN WITH FILTER. RE: CIVIL DWGS.47.CONC. GUTTER, RE: CIVIL DWGS .48.2" DIA. CONDUIT STUB UNDERGROUND CABLE.49.2" DIA. CONDUIT STUB UNDERGROUND TELEPHONE LINE.SITE PLANAS1.1SHEET TITLESHEET NO.SUBMITTALCAD SAVED NAME:PROJECT NO.DRAWN BY:CHECKED BY:OWNER: 21.03.19BUILDING DEPT: 21.05.14O.T.B.:DATESREVISIONS:DATE#REVISIONBYSAFEWAY FUEL CENTER #0055
<br />19533 S. MOUNTAIN HOUSE PKWY.
<br />MOUNTAIN HOUSE, CA 95381 2007730004--www.stantec.com
<br />TEL.
<br />1383 North McDowell Blvd. Suite 250
<br />Petaluma, CA 94954
<br />707.765.1660
<br />Architecture Inc.-881012131316171721246122345811(TYP.)(TYP.)(TYP.)(TYP.)(TYP.)(TYP.)(TYP.)2223(TYP.)26(EXIST.)15293031333432252737384136474948402626WEST BYRON RDMOUNTAIN HOUSE PARKWAY19BLDGCORBLDGCORBLDG
<br />COR
<br />BLDG
<br />COR
<br />PROP
<br />COR PROPCORFC35(TYP.)35(TYP.)14A.FUEL MONUMENT SIGN, SIGN STRUCTURE BY SIGNCONTRACTOR.B.G.C. SHALL COORDINATE THE LOCATION OF THEMONUMENT SIGNS AND SHALL FURNISH AND INSTALL,ELECTRICAL CONDUITS, PULL STRINGS, WATER PROOFJ-BOXES FROM SOURCE OF ELECTRICAL POWER TOMONUMENT SIGNS. FINAL WIRING BY SIGN CONTRACTOR.C.G.C. SHALL RUN CONDUIT THRU TIMER LOCATED INELECTRICAL ROOM OF C-STORE, NOTE BOTH MONUMENTSIGNS SHALL BE WIRED AND CONTROLLED BY C-STOREELECTRICAL ROOM.D.SIGN CONTRACTOR SHALL BE RESPONSIBLE FORSUBMITTING SIGN SHOP DWGS TO BUILDING DEPARTMENT,AND SECURING SIGN PERMITS PRIOR TO FABRICATION OFSIGNS, AND OR SIGN STRUCTURES. SIGN PERMIT SHALL BEA SEPARATE SUBMITTAL PROCESS FROM BUILDING PERMIT.E.SIGN CONTRACTOR SHALL BE RESPONSIBLE FORSUBMITTING SIGN DWGS FOR APPROVAL TO PLANNINGDEPARTMENT PRIOR TO FABRICATION OF SIGNS AND ORANY SIGN STRUCTURES.36CENTER
<br />OF TANKS
<br />15DETECTABLE WARNING SURFACECONCRETE PAVING AND SIDEWALK SURFACEACCESSIBLE ROUTELIMITS OF CONSTRUCTION>>>>>>>18183928474444444445454646467(TYP.)SIGN NOTESKEYED NOTESSYMBOL LEGEND20943EXIST.NEW
<br />141930304215
|