Environmental Health Department
<br />Time In:
<br /> 1:42 pm
<br /> 1:24 pm
<br />Time Out:
<br />Program Element: 1635 - MOBILE FOOD PREPARATION UNIT (MFPU)
<br />Telephone: (510) 250-0427 Owner/Operator: VILLANUEVA, JOSE RAUL
<br />Inspection Type: ROUTINE INSPECTION - Operating Permit
<br />Address: 2440 S AIRPORT WAY, STOCKTON 95206
<br />Date: 11/04/2022Name of Facility: CRUZ CATERING #5F59177
<br />Mobile Food Facility Official Inspection Report
<br />VIOLATIONS AND CORRECTIVE ACTIONS
<br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7;
<br />113700. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health
<br />and have the potential to cause foodborne illness. All major violations must be corrected immediately. Non-compliance may warrant immediate closure of
<br />the food facility.
<br /> #35 Equipment/Utensils Approved and in Good Repair
<br />OBSERVATIONS: Right and left exhaust fans produce loud noise. Repair in 1 week
<br />CALCODE DESCRIPTION: All utensils and equipment shall be fully operative and in good repair. (114175). All utensils and equipment
<br />shall be approved, installed properly, and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5,
<br />114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182)
<br /> #38 Approved / Sufficient Ventilation and Lighting
<br />OBSERVATIONS: 2 light boxes are missing. Provide 2 operational light boxes in 2 weeks.
<br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by
<br />the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation
<br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a
<br />light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas
<br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed
<br />shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1)
<br /> #41 Plumbing Maintained; Approved Back Flow Device
<br />OBSERVATIONS: Cold and hot water pressure from faucets, at the 3 comp sink and hand sink, is weak. Provide adequate
<br />pressure on both stations in 2 weeks.
<br />CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required
<br />by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing
<br />ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose
<br />used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171,
<br />114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269)
<br />Chlorine (Cl):
<br />Name on Food Safety Certificate:Expiration Date:
<br />ppmQuaternary Ammonia (QA):
<br />Heat:ppm º FWarewash Water/Hot Water Ware Sink Temp:º F
<br />Hand Sink Temp:º F
<br />OBSERVATIONS
<br /> 124
<br /> 114
<br />Maria Villanueva December 22, 2023
<br />OVERALL INSPECTION NOTES AND COMMENTS
<br />Page 1 of 2EHD 16-23 Rev. 09/16/2020 Mobile Food Facility OIR
<br />FA0000795 PR0527593 SC001 11/04/2022
<br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
|