Laserfiche WebLink
CSCOVER SHEET <br />AS NOTED 7-ELEVENSHEET INDEX CONTINUEDPROJECT DATAVICINITY MAPPROJECT DIRECTORYDEFERRED SUBMITTALSAPPLICABLE CODESSEPARATE PERMITS7-ELEVEN #10462491110 N. MAIN STREETMANTECA, CA 95336PROTOTYPE: 10/23/2019CSGBC1.0GBC1.1GBC1.2COA1.0COA1.1COVER SHEETGREEN BUILDING CODEGREEN BUILDING CODEGREEN BUILDING CODECONDITIONS OF APPROVALCONDITIONS OF APPROVALA1.0A1.1A1.2A1.3A1.40A1.5GENERAL NOTES, ABBREVIATIONS AND SYMBOLS LEGENDACCESSIBILITY NOTESACCESSIBILITY DETAILSARCHITECTURAL SITE PLANDUMPSTER ENCLOSURE & DETAILSEGRESS PLANA2.0A2.2A2.3CO2 SENSOR PLANDIMENSIONED FLOOR PLAN & INTERIOR WALL TYPESWALL SUBSTRATE AND WALL FINISH PLANA2.4A3.0A3.1REFLECTED CEILING PLANEXTERIOR ELEVATIONSEXTERIOR ELEVATIONSA4.0A4.1BUILDING SECTIONSWALL SECTIONSA5.0A5.1A5.2INTERIOR ELEVATIONSINTERIOR ELEVATIONSA5.4A6.0SLAB & FLOOR FINISH PLANSTOREFRONT & DOOR TYPES & SCHEDULESA6.1A7.0INTERIOR FINISH SCHEDULESWALL DETAILSA7.1CEILING DETAILSA7.3STOREFRONT AND DOOR DETAILSA7.4ROOF DETAILSA7.5EXTERIOR DETAILSA7.6INTERIOR DETAILSGENERALARCHITECTURALSHEET INDEXA7.21DIGITAL MENU BOARD INSTALLATION GUIDE AND DETAILSA7.2DIGITAL MENU BOARD INSTALLATION GUIDE AND DETAILSA5.3INTERIOR ELEVATIONSA1.6ROOF PLANSUMMARY OF WORK218-210-23NEW BUILDING CONSTRUCTIONCONVENIENCE STORE, SITE WORK(I.E. LIGHTING, TRASH & HEALY ENCLOSURE.)COMMERCIALCONVENIENCE STORE ANDFUELING STATION (SEPARATE PERMIT)±31,259 SF±22'-0" (ALLOWABLE BUILDING HEIGHT 35'-0" AFG)SINGLE STORYMERCANTILE GROUP M12.1% (6,163SF)22.9% (11,654 SF)14 STALLS REQUIRED (1 STALL PER 250 SF)13 PARKING STALLS PROVIDED *38NOTYPE VB - NON SPRINKLERED1. ROOF TRUSSES & CALCULATIONS2. BUILDING SIGNAGE3. PREFABRICATED CANOPIES3,065 SF1 EVCS PARKING1 SHORT-TERM BICYCLE PARKING (5% OF PARKING)1 EVCS PARKING5 SHORT-TERM BICYCLE PARKINGASSESSOR'S PARCEL NUMBER(S):PROJECT DESCRIPTION:PROPOSED LAND USE:LOT COVERAGE:LANDSCAPING:PARKING REQUIRED:PARKING PROVIDED:OCCUPANCY LOAD:OCCUPANCY USE GROUP:BUILDING HEIGHT:TYPE OF CONSTRUCTION:SPRINKLERED:TOTAL BUILDING AREA:ZONING:LOT AREADEFERRED SUBMITTALS SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER OFRECORD FOR REVIEW PRIOR TO SUBMITTAL TO THE AUTHORITY HAVING JURISDICTION(AHJ). THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL SAID DEFERREDDESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE AUTHORITY HAVINGJURSDICTION (AHJ).RESTROOM PLUMBING FIXTURESBUILDING OCCUPANT LOAD = 382019 CPC 422.1 - 50% MALE AND 50% FEMALE BASED ON TOTAL OCCUPANT LOAD4. COOLER VAULTTHE DESIGN AND CONSTRUCTION OF THIS WORK SHALL BE IN COMPLIANCE WITH:BUILDING CODE 2019 CBCMECHANICAL CODE: 2019 CMCPLUMBING CODE: 2019 CPCELECTRICAL CODE: 2019 CEC - 2017 NECENERGY CODE: 2019 CBC - TITLE 24FIRE CODE: 2019 CBCACCESSIBILITY CODE: 2019 CBCGREEN BUILDING STANDARDS CODE 2019 GBCAND ALL OTHER LOCAL CODES AND ORDINANCES ADOPTED BY THE CITY OF MANTECAOWNER: 7-ELEVEN3200 HACKBERRY RD.IRVING, TX 75063ARCHITECT:TAIT & ASSOCIATES, INC.ALLEN SIPE3883 RUFFIN ROAD, SUITE 'B'SAN DIEGO, CA 92123TELEPHONE: (619) 995-9506 EMAIL: ASIPE@TAIT.COMAGENT OF OWNER:TAIT & ASSOCIATES, INC.701 N. PARKCENTER DRIVESANTA ANA, CA 92705CONTACT: CHANDRA MIEHETELEPHONE: (916) 669-1823EMAIL: CMIEHE@TAIT.COMSTRUCTURAL ENGINEER:INNOVATIVE STRUCTURALENGINEERING INC.27369 VIA INDUSTRIATEMECULA, CA 92590CONTACT: JOSE MERCADOTELEPHONE: (951) 600-0032EMAIL: JOSE@ISEENGINEERING.COMMECHANICAL ENGINEER:EMPIRE 3 CONSULTING ENGINEERS, INC.7010 ARLINGTON AVENUE, SUITE 205RIVERSIDE, CA 92503CONTACT: BRUCE BOURTELEPHONE: (562) 206-1899EMAIL: BOUR@EMPIRE3.NETELECTRICAL ENGINEER:A&F ENGINEERING GROUP, INC.9320 BASELINE ROAD, SUITE CRANCHO CUCAMONGA, CA 91701CONTACT: LUIS M. FLORESTELEPHONE: (909) 941-3008EMAIL: LMFLORES@A-FENGINEERING.COMCIVIL ENGINEER:TAIT & ASSOCIATES, INC.701 N. PARKCENTER DR.SANTA ANA, CA 92705CONTACT: MIKE SILVEYTELEPHONE: (714) 560-8676EMAIL: MSILVEY@TAIT.COMSITESITE LOCATION MAPA1.3.1ARCHITECTURAL SITE DETAILSA1.41TANK ENCLOSURE - FOR REFERENCE ONLYA2.1ENLARGED RESTROOM PLAN AND DETAILSINTERIOR ELEVATIONSMECHANICALPLUMBINGELECTRICALM1.0MECHANICAL PLANM1.1MECHANICAL ROOF PLANM1.2REFRIGERATION PIPING RISER DETAILM2.0MECHANICAL SPECIFICATIONSM2.1REFRIGERATION SPECIFICATIONSEMS1.0P1.0DRAIN PIPING PLAN, RISER & SCHEDULESP1.1WATER PIPING PLAN & RISERP1.2PLUMBING SLAB PENETRATION PLANP2.0PLUMBING DETAILS &SPECIFICATIONSE0.1SITE POWER PLANE1.1PANEL SCHEDULES & ONE-LINE DIAGRAME1.2ELECTRICAL SLAB PENETRATION PLANE1.3ELECTRICAL HVAC/R PLANE1.4LOW VOLTAGE FLOOR PLANE1.5LOW VOLTAGE DETAILSE1.6ELECTRICAL DETAILSE2.0LIGHTING PLANE3.0ELECTRICAL SPECIFICATIONSE4.0TITLE 24 COMPLIANCE FORMSENERGY MANAGEMENT SYSTEMM3.0TITLE 24 COMPLIANCE FORMSM3.1M3.2E1.0ELECTRICAL FLOOR PLANE4.1TITLE 24 COMPLIANCE FORMSE2.1LIGHTING CONTROL PLANE2.2INTERIOR PHOTOMETRICSE2.3EGRESS PHOTOMETRICS1 HC PARKING SPACE1 HC SPACE (1 VAN ACCESSIBLE)11 STANDARD SPACESBUILDING:FRONT 0' FTREAR 15' FT WITH AT LEAST 5' LANDSCAPESIDE 1 INTERIOR 0' FTSIDE 2 STREET 0' FTLANDSCAPING LOTFRONT N/A FTREAR N/A FTSIDE INTERIOR N/A FTSIDE STREET 20 OR LESS STALLS, A MIN. OF 10' WIDE LS SETBKS REQ'D.ALONG STREET FRONTAGES FOR PARKING.REQUIRED BUILDING SETBACKS:EF-1.0EQUIPMENT FLOOR PLAN - FOR REFERENCE ONLYEF-1.1EQUIPMENT SCHEDULE - FOR REFERENCE ONLYTITLE 24 COMPLIANCE FORMSTITLE 24 COMPLIANCE FORMSA1.42DUMPSTER ENCLOSURE - BLOCK WALL DETAILS1.SIGNAGE2.MONUMENT SIGN3.FUEL DISPENSER4.FUEL CANOPY5.HEALY TANK6.UNDERGROUND STORAGE TANK (INCLUDES PUMP, PIPES, ETC)5. ALARM SYSTEM FOR THE CO2 SYSTEMEF-2.0COUNTER FLOOR PLAN & SCHEDULE - FOR REFERENCE ONLY3883 Ruffin Road Suite B <br />San Diego, CA 92123 <br />p: 714/560/8200 <br />f: 714/560/8211 <br />www.tait.com <br />Since 1964 Los Angeles <br />Anaheim <br />Ontario <br />Sacramento <br />San Diego <br />Boise <br />Dallas <br />Denver <br />Seattle <br />©"TAIT & ASSOCIATES" 2020 ALL RIGHTS RESERVED <br />Job#: <br />Scale: <br />Date: <br />Drawn By: <br />Checked By: <br />Rev. #Date DescriptionSHEET:7-ELEVEN, INC. <br />3200 HACKBERRY, IRVING, TEXAS 75063 <br />SE1237 <br />7-ELEVEN 1046249 <br />1110 N. MAIN ST <br />MANTECA, CA 95336 <br />TICOFALCC 1 9 0 9 1L <br />11 / 21EXPIRESETSTAFOIA <br />N <br />R SNI <br />C <br />E <br />EDCHRAIETA <br />EN <br />FR <br />JR.EK <br />ALLPNSIURINAL:URINAL:10LAVATORY:LAVATORY:12WATERCLOSET:WATERCLOSET:12REQUIRED:PROVIDED:TOILET FIXTURE COUNT: 2019 CPC SECTION 422.2, EXCEPTION (3)...OCCUPANT LOAD OF 50 ORLESS INCLUDING CUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY, DESIGNED FOR USE BYNO MORE THAN ONE PERSON AT A TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES. OCCUPANT LOAD (TABLE 1004.1.2) GROSS AREA / OCCUPANT LOAD FACTORMEANS OF EGRESS: 2MAXIMUM TRAVEL DISTANCE: 69'-2"NUMBER OF EXITS: 2MINIMUM DOOR WIDTH: 0.2 X 38 = 7.6" MIN. REQUIRED(72" + 36") = 108" PROVIDEDMERCANTILE60 SQ. FT. PER OCCUPANTSALES (BUSINESS)100 SQ. FT. PER OCCUPANTTOILETS AND HALLWAY100 SQ. FT. PER OCCUPANT1,7342930932142COOLER / VAULT (STORAGE)300 SQ. FT. PER OCCUPANT3761OFFICE (BUSINESS)100 SQ. FT. PER OCCUPANT501BACK ROOM300 SQ. FT. PER OCCUPANT33813,021 SF 44 SFTOTAL AREA OF BUILDING3,065 SF38 OCC37 1TOTAL STORE:ELEC. RM. 44 SFEQUIPMENT AND FIXTURES3 ADDITIONAL BICYCLE STALLS HAVE BEEN PROVIDED TOREPLACE 1 VEHICLE PARKING STALL.* PARKING REDUCTION:E2.4SITE PHOTOMETRICSSTRUCTURALSN1STRUCTURAL GENERAL NOTESSN2SN3S2.1FOUNDATION PLANS2.2ROOF FRAMING PLANSD1FOUNDATION DETAILSSD2GENERAL FRAMING DETAILSSD3STRUCTURAL DETAILSSD4STRUCTURAL GENERAL NOTESSTRUCTURAL GENERAL NOTESSTRUCTURAL DETAILSS2.3TOWER ROOF FRAMING PLANLANDSCAPEL-1IRRIGATIONL-2IRRIGATIONL-3PLANTINGL-4PLANTINGL-5DETAILSL-6DETAILSL-7DETAILS1TITLE SHEET CIVIL2GENERAL NOTES3DEMOLITION PLAN4HORIZONTAL CONTROL AND SIGNING & STRIPING PLAN5SECTIONS AND DETAILS6PRECISE GRADING PLAN7WET UTILITY PLAN8STORM DRAIN PLAN9EROSION CONTROL PLAN10EROSION CONTROL DETAILS11121314151617181920DETAILSDETAILSCALTRANS RSP A87ACALTRANS RSP A88ACALTRANS RSP A90ASTREET IMPROVEMENT PLAN & PROFILE - MAIN STSTREET IMPROVEMENT PLAN & PROFILE - LOUISE AVEMEDIAN SECTIONS - 25 FT. INTERVALSCONDITIONS OF APPROVALCONDITIONS OF APPROVALS:\Commercial\2020\7Eleven\SE1237 1110 N Main Manteca #1046249\04-CD\AR\0-CS0.0 COVER SHEET.dwg, 11/23/2020 10:22:40 AM, DWG To PDF.pc3 San Joaquin County Environmental Health Department 1868 E. Hazelton Ave. Stockton, CA 95205 (209) 468-3420 APPROVED WITH CONDITIONS For conditions, please see approval letter dated: Approved by:_______________________Date:_______________ 12-29-20Dec 29, 2020 Gehane Fahmy