My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1110
>
1600 - Food Program
>
PR0161074
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:25:05 PM
Creation date
11/10/2022 2:17:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161074
PE
1625
FACILITY_ID
FA0000794
FACILITY_NAME
7-ELEVEN INC # 41530
STREET_NUMBER
1110
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21821023
CURRENT_STATUS
02
SITE_LOCATION
1110 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A1.3ARCHITECTURAL SITE PLAN GENERAL NOTESKEYNOTESLEGENDSCALE:1ARCHITECTURAL SITE PLAN1" = 20'-0"1.REFER TO STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, CIVIL, AND LANDSCAPEDRAWINGS FOR ADDITIONAL INFORMATION.2.REFER TO THE FOLLOWING SHEETS FOR ADDITIONAL INFORMATION:A1.31 - ARCHITECTURAL SITE DETAILS - ENLARGED H.C. PARKING STALLSA1.40 - TRASH ENCLOSURE PLANA1.41 - TANK ENCLOSUREA2.00 - GENERAL FLOOR PLAN3. REFER TO CIVIL DRAWINGS FOR SITE DIMENSIONSLOT LINEPATH OF TRAVELCONCRETE PAVING/SIDEWALK AREACOUNT OF PARKING STALLSMONUMENT SIGNFIRE HYDRANT BY OTHERSACCESSIBLE PARKING STALLSTREET LIGHT BY OTHERSADA PARKING SIGN#(N) SITE LIGHT POLESEE ELECTRICALLOCATION SPECIFIC NOTES1.LANDSCAPING MUST BE IN PLACE BEFORE ISSUANCE OF THE CERTIFICATE OFOCCUPANCY. A HOLD ON OCCUPANCY SHALL BE PLACED ON THE PROPOSEDDEVELOPMENT UNTIL SUCH TIME THAT LANDSCAPING HAS BEEN APPROVED ANDVERIFIED FOR PROPER INSTALLATION BY THE DEVELOPMENT SERVICES DIVISION.2.ALL ACCESSIBLE STALLS SHALL BE MARKED WITH THE INTERNATIONAL SYMBOL OFSPACES AND A WARNING THAT VEHICLES IN VIOLATION OF SECTION 10-1017 OF THEMUNICIPAL CODE SHALL BE TOWED AWAY. THE INTERNATIONAL SYMBOL ANDTOW-AWAY WARNING SHALL BE POSTED CONSPICUOUSLY ON SEVEN-FOOT POLES.3.APPLICANTS ARE ENCOURAGED TO PROVIDE SHARED VEHICLE AND PEDESTRIANACCESS BETWEEN ADJACENT PROPERTIES FOR CONVENIENCE, SAFETY, ANDEFFICIENT CIRCULATION. A JOINT ACCESS COVENANT SHALL BE REQUIRED.4.SIGNS, OTHER THAN DIRECTIONAL SIGNS, IF APPLICABLE, ARE NOT APPROVED FORINSTALLATION AS PART OF THIS SPECIAL PERMIT.13ELECTRICAL ROOM DOOR15CLEAN AIR SEPARATOR AND VENTS WITH ENCLOSURE (UNDER SEPARATE PERMIT)16FUEL VENTS (UNDER SEPARATE PERMIT)14ELECTRICAL DISTRIBUTION ENCLOSURE (MDP)17FUELING DISPENSER (TYP. OF 6) (SEPARATE PERMIT)18FUEL CANOPY (SEPARATE PERMIT)19EXTERIOR 7-11 EQUIPMENT, SEE EF-1.020ADA PARKING SIGNAGE, SEE 4/A1.3.121CONCRETE CURB, TYP.22NEW SITE POLES, SEE DET. 12/A1.3.123NEW GAS METER, SEE MECHANICAL1LOT LINE2ACCESSIBLE PATH OF TRAVEL TO THE PUBLIC RIGHT OF WAY3ACCESSIBLE PATH OF TRAVEL FOR DISABLED ACCESSIBLEPARKING STALL AND PUBLIC WAY TO PUBLIC ENTRANCE.4ACCESSIBLE STALL AND CURB RAMP5PARKING STALL6MONUMENT SIGNAGE; UNDER SEPARATE PERMIT. (BY OTHER)7TRANSFORMER. SEE ELECTRICAL.8LANDSCAPE AREA (UNDER SEPARATE PERMIT)9TRASH ENCLOSURE, SEE SHEET A1.410AIR / WATER / VACUUM STATION11BICYCLE RACK FOR (5) BICYCLES MINIMUM. SEE DETAIL 2/A1.3.112MAIN ENTRY DOOR24UNDERGROUND FUEL TANKSWORK LIMIT LINE<<<256" PIPE BOLLARD WITH PLASTIC COVER, SEE DET. 8/A1.3.126PARKING BOLLARDS ARE TO BE PLACED IN PARKING STALLS ADJACENT TO BUILDING.IF ANY PART OF THE STALL IS ADJACENT TO THE BUILDING BUT NOT THE ENTIRE WIDTH,EXTEND BOLLARDS TO COVER ENTIRE STALL.27SECOND EGRESS DOOR29FIRE HYDRANT28ELECTRIC VEHICLE CHARGING SPACE PER SECTION 5.106.3 OF CGC3883 Ruffin Road Suite B <br />San Diego, CA 92123 <br />p: 714/560/8200 <br />f: 714/560/8211 <br />www.tait.com <br />Since 1964 Los Angeles <br />Anaheim <br />Ontario <br />Sacramento <br />San Diego <br />Boise <br />Dallas <br />Denver <br />Seattle <br />©"TAIT & ASSOCIATES" 2020 ALL RIGHTS RESERVED <br />Job#: <br />Scale: <br />Date: <br />Drawn By: <br />Checked By: <br />Rev. #Date DescriptionSHEET:7-ELEVEN, INC. <br />3200 HACKBERRY, IRVING, TEXAS 75063 <br />SE1237 <br />7-ELEVEN 1046249 <br />1110 N. MAIN ST <br />MANTECA, CA 95336 <br />TICOFALCC 1 9 0 9 1L <br />11 / 21EXPIRESETSTAFOIA <br />N <br />R SNI <br />C <br />E <br />EDCHRAIETA <br />EN <br />FR <br />JR.EK <br />ALLPNSI0SCALE:10'20'40'1"=10'71516111101235TYP.81A1.4.11A1.461817TYP.24NOTE:1.UNDERGROUND STORAGE TANKS AND ASSOCIATEDPIPING AND EQUIPMENT ARE ALL SEPARATE PERMITS2625271314228FFFE. LOUISE AVENUEN. MAIN STREET <br />7-ELEVEN±3,010 SFCANOPY60' x 100'23421248'-0"20'-0"25'-0"26'-0"10'-9"5'-0"30'-11" <br />89'-8"25'-0"5'-6"26'-0" <br />70'-4"8'-0"20'-0"25'-4"9'-0"TYP5'-0"5'-0"5'-0"<<<<<<<<<<<<<<<<<<<<<<<<< <br />< <br />< <br />< <br />< <br />< <br />< <br /><<<<<<91220192820'-0"12'-0"5'-0"9'-0" <br />TYP. <br />10'-4"40'-0"DRIVEWAY35'-0"DRIVEWAY29 <br />4'-10"<<<<<<<<<<±4'-1"S:\Commercial\2020\7Eleven\SE1237 1110 N Main Manteca #1046249\04-CD\AR\A1.30 SITE PLAN.dwg, 11/25/2020 10:18:44 AM, DWG To PDF.pc3
The URL can be used to link to this page
Your browser does not support the video tag.