Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> U ; i y <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WIRE MESH WEST COAST LLC 1 15380 S MCKINLEY AVE, LATHROP November 15, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 CCR 66262.40(c) Failed to retain hazardous waste determination including waste analysis on site for 3 years. <br /> OBSERVATION: The steel dust waste is being disposed of as non-hazardous waste. The business operator does <br /> not have hazardous waste determination records on-site that support the current handling and disposal of the <br /> waste. <br /> REGULATION GUIDANCE:A business operator shall keep records of any hazardous waste determinations made <br /> in accordance with Title 22 California Code of Regulations(CCR)section 66262.11 for at least three years from the <br /> date that the waste was last sent to an on-site or off-site treatment, storage, or disposal facility. The records may <br /> include Safety Data Sheets(SDS), waste test results or other hazardous waste determination documentation. <br /> CORRECTIVE ACTION: The violation was corrected during the inspection by obtaining a copy of the waste analysis <br /> dated 3-23-20 from the Environmental Health Department staff. No further action is required to correct this <br /> violation. <br /> This is a Class II violation. <br /> 104 CCR 66262.34(d)(2)No modified contingency plan. <br /> OBSERVATION: Modified contingency plan information was not posted at the facility. <br /> REGULATION GUIDANCE: The business operator must post the following information next to telephones or in <br /> areas directly involved in the generation and accumulation of hazardous waste: the name and emergency <br /> telephone number of the emergency coordinator, the location of fire extinguishers and spill control material, and the <br /> telephone number of the fire department unless the facility has a direct alarm. <br /> CORRECTIVE ACTION: Immediately post the modified contingency plan information or keep a copy of a complete <br /> consolidated emergency response/contingency plan on-site. Provide a statement to the San Joaquin County <br /> Environmental Health Department that the correction is complete. <br /> This is a repeat violation, Class II. <br /> FA0010620 PR0517950 SCO01 11/15/2022 <br /> EHD 22-01 Rev.12/06/2021 Page 4 of 8 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />