0 Guide for Safe Operation of <br />the San -I -Pak Sterilizer/Compactor <br />Index No. SAF 30.95.00 <br />probe provided. Assure all plastic is inside the chamber to permit a good seal of <br />the load door gasket when locking door. <br />4. Remove the latch from the door, once again, insuring that no plastic is outside the <br />chamber, and close the load door. Lock the door by turning wheel to the right <br />(clockwise). There is a green and red light to the lower right side of the door. <br />The green light should be on. <br />Below the digital display, you will find a keyboard with F1 through E6 and the <br />numbers 1 through 0. You will touch Fl. The message is to enter your User <br />Number. Enter the Janitor position you are working on the schedule, for example, <br />position #8, would be entered as 0-0-0-8, Position #10 as 0-0-1-0 and then touch <br />enter, you will receive a message on the digital display "If you want auto <br />discharge, press 0, if you do not, press 1." You will touch 0 in all cases unless <br />otherwise directed by the Executive Housekeeper or other appropriate authority. <br />You will see the red light come on indicating the load door is locked. <br />6. The vacuum cycle will begin, It will remain in this cycle until the computer <br />recognizes 20 lbs. by printing this on the strip of paper, or cycles out of time <br />which is 10 minutes. You should re -check the machine within 15 minutes of <br />beginning the vacuum cycle. Once the vacuum cycle is complete it will cycle into <br />the sterilization cycle which is of 30 minutes duration. Should it not reach the <br />sterilization cycle, it will have gone into vacuum failure. At this time, you must <br />call Maintenance immediately. The load must not remain in the chamber for <br />more than an hour without the load being run. this will generally result in a <br />melt down and stand an excellent chance of resulting in a fire. <br />7. In case you observe smoke coming from the top of the San -I -Pak or the <br />compactor, call maintenance. Should you see flames of any type coming from <br />the unit, the fire alarm should be sounded through the normal channels <br />because it threatens the hospital. No doors on the machine will be opened <br />under this condition for any reason. A call to Maintenance will normally be <br />sufficient under smoke conditions. Maintenance will be able to run the load <br />to put the melt down or fire condition out. <br />This is a shortened version of the step by step operation. <br />a. Check steam pressure, 70 PSI minimum <br />b. Open load chamber door <br />C. Load chamber <br />d. Lock load chamber door <br />e. Press F 1 on keyboard <br />f. Enter position number on keyboard <br />