SOAP TANKSOAP TANKFREEZER(BY OTHERS)REFRIGERATOR(BY OTHERS)REFRIGERATOR(BY OTHERS)ICE MAKER(BY OTHERS)SODA DISP.(BY OTHERS)T-1TITLE SHEETLEGACY FIELDS PHASE 1ERestroom / Concession / Storage BuildingTracy, CA5-Aug-21 4:34 PM
<br />PROJECT INFORMATIONPROJECT OWNER:CITY OF TRACY333 Civic Center PlazaTracy, CA 95376CONTACT:Brian MacDonaldPHONE:(209) 831-6233E-MAIL:brian.macdonald@ci.tracy.ca.usSITE ADDRESS: LEGACY FIELDS - PHASE 1E - 4901 N Tracy Blvd, Tracy CA 95304PROJECT CONSULTANT:VERDE DESIGN, Inc.2455 The Alameda, Suite 200Santa Clara, CA 95050CONTACT:Derek MckeePHONE:(408) 850-3411E-MAIL:derek@verdedesigninc.comUtility LocationNOTE: FINAL LOCATIONS OF P.O.C. TO BE COORDINATED WITH P.R.C. ANDTO BE CONFIRMED ON SITE . UTILITY BOXES TO BE PROVIDE BY OTHERS.These documents are applicable only to the elements and loading criteriaspecifically provided herein. These documents shall not be construed in anyway to specify, certify or design any aspects of the building not containedherein. Specified design criteria are based solely on information provided bythe client and must be verified and approved by the local authority havingjurisdiction. ICC NTA, LLC is not responsible for fabrication or erection. If itis suspected that these documents have been modified, substituted or alteredin any way, contact ICC NTA, LLC at (574) 773-7975 to obtain a file copy.ICC NTA, LLC, 305 N Oakland AveNappanee, Indiana 46550STRUCTURAL ONLYThis certification is for structural design only. All other matters of codecompliance including but not limited to allowable area, fire resistance, andegress are the responsibility of others.Job No.Current Date:Drawn by:Checked by:COPYRIGHT 2021, PUBLIC RESTROOM COMPANY THISMATERIAL IS THE EXCLUSIVE PROPERTY OF PUBLICRESTROOM COMPANY AND SHALL NOT BEREPRODUCED, USED, OR DISCLOSED TO OTHERSEXCEPT AS AUTHORIZED BY THE WRITTENPERMISSION OF PUBLIC RESTROOM COMPANY11005CITY of TRACYTracy, CANo.DescriptionDateStart Date:SHEET TITLE:PROJECT NAME AND LOCATION:PROJECT OWNER:06/08/2021DO NOT SCALE - DIMENSIONS PRESIDE24x36 SHEET = SCALE AS NOTED11x17 SHEET = NTSKMNS08/05/20212587 Business Pkwy, Minden, NV 89423Ph: 888-888-2060 Fax: 888-888-1448Building Better Places To Go.LEGACY FILEDS PHASE 1ETracy, CALEGACY FILEDS PHASE 1E - Tracy, CACONSTRUCTION DOCUMENTS08/05/2021CONSTRUCTION DOCUMENTS - 08/05/2021 CODE COMPLIANCEAPPLICABLE CODES:TYPE OF CONSTRUCTION:V-BDESCRIPTION:RESTROOM / CONCESSION / STORAGEOCCUPANCY & USE:FLOOR AREA:RESTROOMS, UTILITY CHASE,CONCESSION & STORAGEPRC JOB NUMBER:11005955 s.f.2019 CALIFORNIA BUILDING CODE2019 CALIFORNIA PLUMBING CODE2019 CALIFORNIA ELECTRICAL CODE2019 CALIFORNIA GREEN CODE2019 CALIFORNIA ENERGY CODEGENERAL NOTESPRC MODEL NUMBER:SS-264--CN2-ST-DF-BF- THE STRUCTURAL DESIGN DETAILS HEREIN ARE SPECIFIC TO THE BUILDING SIZE ANDMODULE CONFIGURATION SHOWN ON THE FLOOR PLAN OF THESE DRAWINGS.- LOCATION OF THIS BUILDING SHALL MEET REQUIRED PROPERTY CODE SETBACKS PERLOCAL JURISDICTION.- ACCESSIBILITY TO THIS STRUCTURE SHALL BE IN CONFORMANCE WITH LOCAL CODEINCLUDING ALL PATHWAYS, RAMPS AND PATHS OF TRAVEL FOR PARKING TO THE BUILDING.- SOIL BEARING REQUIREMENT IS 1500 PSF, SUB GRADE COMPACTION AT 90%.- BUILDING PLUMBING SYSTEM IS BASED UPON FULL FLOW EXISTING WATER SERVICE. LOSSOF REQUIRED FLOW RATE OF 10 GPM OR PRESSURE BELOW 35 PSI MAX NECESSITATE ANINTERMEDIATE WELL TANK AND CHECK VALVE IN LINE.- ALL DIMENSIONS HEREIN ARE NOMINAL AND SUBJECT TO CHANGE AS LONG AS THEY DO NOTVIOLATE CODE.- THIS BUILDING IS DESIGNATED AS A NON-HABITABLE SPACE AND IS NOT DESIGNED TO BEHEATED OR COOLED.- THIS BUILDING DOES NOT CONFORM WITH TITLE 24 MINIMUM INSULATION REQUIREMENTS ASTHIS IS A NON-HABITABLE STRUCTURE.- THIS BUILDING IS NOT DESIGNED OR APPROVED FOR WUI LOCATION.- ALL WORK REQUIRED TO BE COMPLETED ON SITE SUBJECT TO REVIEW, APPROVAL ANDINSPECTION BY LOCAL AHJ.a. SITE CONCRETE FOUNDATION (IF APPLICABLE)b. COMPACTED BUILDING PAD ENGINEEREDc. UNDER SLAB UTILITY PIPING (SEE NOTE)d. ELECTRICAL SERVICE AS REQUIREDe. WATER SERVICE AS REQUIREDf. SEWER (DWV) SERVICE AS REQUIREDg. CONCRETE WALKWAY COMPLIANT WITH PATH OF TRAVEL FROM ACCESSIBLE PARKINGNOTE: PUBLIC RESTROOM COMPANY WILL ONLY FURNISH AND INSTALL UNDERGROUNDUTILITIES (UNDER SLAB) EXTENDING 6 FEET (MAX.) BEYOND THE BUILDING LINE. MIN. OF 24" -MAX. OF 36" BELOW GRADE - U.N.O.- SITE INSTALLATION DETAILS ARE NOTED ON SHEETS S-1 FOR STRUCTURAL CONNECTIONS,A-2 FOR WEATHERIZATION FINISH, P-1 FOR PLUMBING CONNECTIONS & E-1 FOR ELECTRICALCONNECTIONS IN ACCORDANCE w/ SECTION 4368.a. SERVICE HOOKUPS (PLUMBING AND ELECTRICAL CONNECTIONS).b. PATCH AND FINISH AT CRANE PICK LOCATIONS AS NEEDED.c. INSTALL AND CONNECT PLUMBING DRAIN TRAPS ASSEMBLIES PER P-1 HEREIN.d. INSTALL ROOFING.e. INSTALL BACKER ROD AND CAULK AT MODLINE.f. CAULK FLOOR AT MODLINE AND FILL PICK POINT LOCATIONS.g. INSTALL MOD LINE CONNECTORSNONSEPARATED MIXEDUSE PER 508.3B - CONCESSIONU (WITH ACCESSIBILITY PROVISIONS) - RESTROOMSS-2 - STORAGE & UTILITY CHASEDESIGNER / CERTIFIED MANUFACTURER:PUBLIC RESTROOM COMPANY2587 Business ParkwayMinden, NV 89423CONTACT:Chad KaufmanPHONE:(888) 888-2060FAX:(888) 888-1448E-MAIL:chad@publicrestroomcompany.comSTRUCTURAL ENGINEER:ICC NTA, LLC305 Oakland AveNappanee, IN 46550CONTACT:Eric J. TomposPOSITION:Structural EngineerPHONE:(574) 773-7975EMAIL:etompos@icc-nta.orgDRAWING INDEXSHEETST-1TITLE SHEETACACCESSIBILITY COMPLIANCEA-1FLOOR PLAN, STRUCTURAL DESIGN & SCHEDULESA-2EXTERIOR ELEVATIONS & FINISH SCHEDULEA-3EQUIPMENT PLAN, INTERIOR ELEVATIONS & SCHEDULESP-1.1PLUMBING PLANS & SCHEDULESE-1ELECTRICAL PLAN & SCHEDULESS-1CONCRETE SLAB & STEEL PERIMETER PLAN & DETAILSA-1.1BUILDING SECTIONS & ROOF FRAMING PLANCONSTRUCTION DOCUMENTS - 08/05/2021
<br />PM PLAN REVIEW - 06/16/2021DESIGN LOADSDESIGN LOADSSTRUCTURAL DESIGN CRITERIAGRAVITY LOADSSEISMICFLOOR LIVE125 psfSEISMIC DESIGN CATEGORYDSITE CLASSDFLOOR DEAD80 psfIMPORTANCE FACTOR1.0ROOF LIVE20 psfRISK CATEGORYIIROOF DEAD10 psfMAPPED ACCELERATIONSEXTERIOR WALL DEAD50 psfSS2.00S10.75SNOWSPECTRAL RESPONSEGROUND SNOW, Pg0 psfSDS1.33FLAT-ROOF SNOW, Pf0 psfSD11.24IMPORTANCE FACTOR, Is1.00SEISMIC FORCE RESISTING SYSTEMA7EXPOSURE FACTOR, Ce1.00DESIGN BASE SHEAR0.27WTHERMAL FACTOR, Ct1.00RESPONSE MODIFICATION FACTOR5.0ANALYSIS PROCEDUREASCE7-16WINDULTIMATE WIND SPEED, Vult115 mphFLOODEXPOSURE CATEGORYCBUILDING SHALL NOT BE LOCATED, IN WHOLE OR INPART, IN A FLOOD HAZARD AREA AS ESTABLISHEDBY THE AUTHORITY HAVING JURISDICTION UNLESSSET ON A FOUNDATION DESIGNED IN ACCORDANCEWITH ASCE/SEI 25. THE FLOOD RESISTANTFOUNDATION SHALL BE DESIGNED BY A REGISTEREDDESIGN PROFESSIONAL AND CONSTRUCTED TORESIST ALL FLOOD LOADS WITHOUT TRANSFERRINGLOADS TO THE MODULAR STRUCTURE.RISK CATEGORYIIINTERNAL PRESSURE, Gcpi+/- 0.18MEAN ROOF HEIGHT15 FtBUILDING SHALL NOT BE PLACED ON THEUPPER HALF OF A HILL OR ESCARPMENTEXCEEDING 15 FEET IN HEIGHTCOMPONENTS & CLADDING WIND LOADSEND ZONEINTERIOR ZONECOMPONENT(psf)(psf)WINDOWS & SIDING+17.3 / -23.2+17.3 / -18.8DOORS+14.7 / -18.0+14.7 / -16.2ROOF CLADDING+12.9 / -55.5+12.9 / -32.0ROOF OVERHANGS-69.0-51.4DESIGN SUBMITTAL - 06/234/2021
<br />STRUCTURAL REVIEW - 07/29/2021P-1.2PLUMBING PLANS & DETAILS08/09/2021NTA, Inc., 305 N Oakland AveNappanee, Indiana 46550R EG ISTER
<br />E
<br />D
<br />PROFESSIONALENGINEERE
<br />R
<br />I
<br />C J.TOMPOSCIVIL09-30-2022San Joaquin County Environmental Health Department 1868 E. Hazelton Ave. Stockton, CA 95205 (209) 468-3420 APPROVED WITH CONDITIONS For conditions, please see approval letter dated: Approved by:_______________________Date:_______________ 2-1-22Feb 01, 2022 Kadeanne Linhares
|