My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SNEDEKER
>
809C
>
2200 - Hazardous Waste Program
>
PR0527608
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2022 5:01:34 PM
Creation date
12/15/2022 4:53:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0527608
PE
2226
FACILITY_ID
FA0018706
FACILITY_NAME
CANARY RENEWABLES CORP
STREET_NUMBER
809C
STREET_NAME
SNEDEKER
STREET_TYPE
AVE
City
STOCKTON
Zip
95203
APN
16203007
CURRENT_STATUS
01
SITE_LOCATION
809C SNEDEKER AVE
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAFETY DATA SHEET <br /> AltAir Paramount Diesel Fuel Oil <br /> CHRONIC : <br /> Secondary effects of ingestion and subsequent aspiration into the lungs may cause pneumatocele ( lung cavity) formation <br /> and chronic lung dysfunction . <br /> TARGET ORGANS : ACUTE : Eye , Respiratory System CHRONIC : Respiratory System <br /> SECTION 3 = COMPOSITION and INFORMATION ON INGREDIENTS <br /> HAZARDOUS INGREDIENTS: CAS # EINECS # ICSC # WT % GHS HAZARD CLASShFICATiON S <br /> Renewable Hydrocarbons (Diesel Flammable Liquid Cat, 3, Aspiration Hazard <br /> Type Fraction) 928771 -01 - 1 618-882-6 Not Listed 100% Cat 2 , STOT SE Cat 3 <br /> Balance of other ingredients are non-hazardous or less than 1 % in concentration (or 0 . 1 % for <br /> carcinogens, reproductive toxins , or respiratory sensitizers) , 1 11 <br /> NOTE : This product has been classified in accordance with the hazard criteria of the 29CFR1910 . 1200 and the SDS contains all the information <br /> required by the CPR , EU Directives and the Japanese Industrial Standard JIS Z 7250: 2000, <br /> SECTION 4 - FIRST -AID MEASURES <br /> Contaminated individuals of chemical exposure must be taken for medical attention if any adverse effect occurs . Rescuers should be <br /> taken for medical attention , if necessary . Take copy of label and SDS to health professional with contaminated individual . <br /> EYE CONTACT : If product enters the eyes , open eyes while under gentle running water for at least 15 minutes . Seek medical <br /> attention if irritation persists . <br /> SKIN CONTACT : Wash skin thoroughly after handling . Seek medical attention if irritation develops and persists . Remove <br /> contaminated clothing . Launder before re-use . <br /> INHALATION : If breathing becomes difficult , remove victim to fresh air. If necessary , use artificial respiration to support <br /> vital functions . Seek medical attention if breathing dificulty continues . <br /> INGESTION : If product is swallowed , call physician or poison control center for most current information . If professional <br /> advice is not available , do not induce vomiting . Never induce vomiting or give diluents (milk or water) to someone who is <br /> unconscious , having convulsions , or who cannot swallow. Seek medical advice . Take a copy of the label and/or MSDS <br /> with the victim to the health professional . <br /> MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE : Pre-existing respiratory system problems may be aggravated by <br /> prolonged contact. <br /> RECOMMENDATIONS TO PHYSICIANS : Treat symptoms and reduce over-exposure . <br /> SECTION 5 - FIRE -FIGHTING MEASURES <br /> FLASH POINT : 125 ° - 150 ° F ( Estimated ) <br /> AUTOIGNITION TEMPERATURE : 500 ° F ( Estimated ) <br /> FLAMMABLE LIMITS ( in air by volume , %) : Lower ( LEL) : 0 . 5% Est . Upper ( UEL) : 4 . 45 Est . <br /> FIRE EXTINGUISHING MATERIALS : Extinguish with foam , carbon dioxide , dry powder or water fog . <br /> UNUSUAL FIRE AND EXPLOSION HAZARDS : Combustible liquid ! This material releases vapors when heated above <br /> ambient temperatures <br /> Explosion Sensitivity to Mechanical Impact . Not Sensitive , <br /> Explosion Sensitivity to Static Discharge : Sensitive <br /> SPECIAL FIRE-FIGHTING PROCEDURES : Incipient fire responders should wear eye protection . Structural <br /> firefighters must wear Self-Contained Breathing Apparatus and full <br /> protective equipment . Isolate materials not yet involved in the fire and <br /> protect personnel . Move containers from fire area if this can be done <br /> without risk ; otherwise , cool with carefully applied water spray . If possible , <br /> prevent runoff water from entering storm drains , bodies of water, or other <br /> environmentally sensitive areas . <br /> Page 2 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.