Laserfiche WebLink
Southern California Office <br />REGION 86 <br />PHONE: (714) 957-1500 <br />EMAIL: reg86@captiveaire.com <br />FOR QUESTIONS, CALL THE <br />1 7224 <br />ND-2-PSP-F CAPTIVEAIRE 8' 0"600 <br />DEG I HEAVY 225 1800 4"14"1800 1684 -0.698"1500 430 SS <br />WHERE EXPOSED ALONE ALONE <br />HOOD <br />NO TAG MODEL MANUFACTURER LENGTH <br />MAX <br />COOKING <br />TEMP <br />TYPE APPLIANCE <br />DUTY <br />DESIGN <br />CFM/FT <br />TOTAL <br />EXH CFM <br />EXHAUST PLENUM <br />RISER(S) <br />WIDTH LENG HEIGHT DIA CFM VEL SP <br />TOTAL <br />SUPPLY <br />CFM <br />HOOD <br />CONSTRUCTION <br />HOOD CONFIG <br />END TO <br />END ROW <br />1 CAPTRATE SOLO FILTER 5 20"16"85% SEE FILTER SPEC 3 L55 SERIES E26 NO RIGHT 12"x72"x24"TANK FIRE <br />SUPPRESSION 4.0 SC-111110FP <br />1 LIGHT <br />1 FAN <br />YES 781 <br />LBS <br />HOOD <br />NO TAG <br />FILTER(S) <br />TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS <br />LIGHT(S) <br />QTY TYPE WIRE <br />GUARD <br />UTILITY CABINET(S) <br />LOCATION SIZE <br />FIRE SYSTEM <br />TYPE SIZE <br />ELECTRICAL <br />MODEL # <br />SWITCHES <br />QUANTITY <br />FIRE <br />SYSTEM <br />PIPING <br />HOOD <br />HANGING <br />WEIGHT <br />1 <br />FIELD WRAPPER 18.00" HIGH FRONT, LEFT, RIGHT. <br />BACKSPLASH 80.00" HIGH X 108.00" LONG 430 SS VERTICAL. <br />RISER SENSOR INSTALL 6IN PLEN. <br />HOOD <br />NO TAG OPTION <br />1 Front 108"16"6"MUA <br />MUA <br />12" <br />12" <br />28" <br />28" <br />750 <br />750 <br />0.182" <br />0.182" <br />HOOD <br />NO TAG POS LENGTH WIDTH HEIGHT TYPE <br />RISER(S) <br />WIDTH LENG DIA CFM SP <br />PATENT NUMBERS <br />AC-PSP WALL (CANADA) - CA PATENT 2820509. <br />AC-PSP (UNITED STATES) - US PATENT 7963830 B2. <br />AC-PSP ISLAND (CANADA) - CA PATENT 2520330. <br />HOOD CORNER <br />HANGING ANGLE <br />(WEIGHT BEARING <br />ANCHOR POINT <br />FOR HOOD). <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUTS. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL ALL-THREAD. <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUT. <br /> ASSEMBLY INSTRUCTIONS <br />HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 <br />(MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING <br />ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS <br />AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE <br />DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING <br />ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED <br />THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 <br />FT-LBS. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUTS. <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER. <br /> HOOD CORNER <br />HANGING ANGLE <br />(HARDWARE BY INSTALLER) <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUT. <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER. <br />FULL LENGTH <br />HANGING ANGLE <br />(WEIGHT BEARING <br />ANCHOR POINT <br />FOR HOOD). <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUTS. <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL ALL-THREAD. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUT. <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER. <br /> ASSEMBLY INSTRUCTIONS <br />HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 <br />(MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING <br />ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS <br />AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE <br />DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. <br />SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR <br />FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED <br />THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 <br />FT-LBS. <br /> FULL LENGTH <br />HANGING ANGLE <br />(HARDWARE BY INSTALLER) <br />SUPPLY PLENUM <br />HANGING ANGLE <br />(WEIGHT BEARING <br />ANCHOR POINT <br />FOR SUPPLY <br />PLENUM). <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUT. <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUTS. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL ALL-THREAD. <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER. <br />1/2" - 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUT. <br /> ASSEMBLY INSTRUCTIONS <br />HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 <br />(MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING <br />ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS <br />AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE <br />DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. <br />SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR PSP <br />HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH <br />BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. <br />SUPPLY PLENUM <br />HANGING ANGLE <br />(HARDWARE BY INSTALLER) <br />1 TANK Fire Suppression 4.0 3 FIRE CABINET RIGHT RIGHT, HOOD 1 <br />FIRE <br />SYSTEM <br />NO <br />TAG TYPE SIZE FLOW <br />POINTS <br />INSTALLATION <br />SYSTEM LOCATION ON HOOD <br />SYSTEM DESIGN VERIFICATION (SDV) <br />IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A <br />COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER <br />ALL INSPECTIONS ARE COMPLETE. <br />ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE <br />ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES <br />WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO <br />RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND <br />BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT <br />BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES. <br />DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A <br />RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE <br />WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. <br />SHEET NO. <br />SCALE: <br />DWG.#: <br />DRAWN <br />DATE: <br /> BY: <br />REVISIONS <br />www.captiveaire.com ACCORDANCENo. 96BUILTNFPAWITHINSLIDTER4996088 <br />MASTER DRAWING <br />AH-86Mountain Mike's Pizza - Mountain House CAMountain House, CA, 95391Southern California Office3002 Dow Ave., Suite 410, Tustin, CA, 92780 PHONE: (714) 957-1500 FAX: (919) 227-5975 EMAIL: reg86@captiveaire.comCAPTIVEAIRE DRAWINGS <br />M-4.0 <br />PRINTED DATE: 07-21-2021PROJECT NAME/ADDRESS: <br />STAMP <br />@Mountain House <br />ARCHITECT <br />ARCH PROJECT #: <br />JOB NUMBER <br />DRAWN BY <br />SHEET CONTENT <br />SHEET NO <br />ISSUE DATE: <br />REVISIONS: <br />EM <br />21-___ <br />CHECK BY <br />ADR <br />ARCHITECTURE <br />GWA <br />1000 Corporate Center Drive <br />Suite 550 <br />Monterey Park, CA 91754 <br />tel: (626) 288-6898 <br />Member of The American Institute of Architects <br />REN. 04-30-2023