My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2300 - Underground Storage Tank Program
>
PR0231989
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2024 11:23:57 AM
Creation date
1/10/2023 9:09:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231989
PE
2361
FACILITY_ID
FA0003976
FACILITY_NAME
VALLEY PACIFIC CHARTER WAY CARDLOCK
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337016
CURRENT_STATUS
01
SITE_LOCATION
1501 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQ U I N Environmental Health Department <br /> PC <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> VALLEY PACIFIC CHARTER WAY CARDLOCK 1 / 13/2023 <br /> 209) 948-9412 <br /> Facility Address : 1501 W CHARTER WAY, STOCKTON CA 95206 CERS ID: 10181557 <br /> Inspection Contact: Jordan Johnson Title: Environmental Contact Phone: (209) 639-6254 <br /> Inspection Type: ROUTINE INSPECTION - Operating Permit Program: 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> ❑ Inspection ❑ Photos ❑ Samples I- i j ( I C 00 <br /> Service Technician Onsite: Exp, Data: Designated Operator: Fxp. D te: <br /> tP� c1nG� rdC �' 2 = Au r C 0 hr%CqOft I Ci <br /> Service Technician Manufacturer's Training : <br /> CCR = Title 23 California Code of R gulations HSC = Health and Safety Code CFR = Code of Federal Regulations EHD = Environmental Health Department <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284; CCR Failure to obtain a permit to operate from the EHD including but not limited to unpaid permit fees o V OR o COS <br /> 2711 (d) <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST o V OR ❑ COS <br /> 103 CCR 2635(01 2636(c)(2) Failure to submit the UST Certification of Installation/Modification o V OR o COS <br /> 104 CCR 2632(d) (1 ) , Failure to submit a complete and accurate UST Monitoring Plan o V OR o COS <br /> 2634 (d) <br /> 105 CCR 2632(d) (2) , Failure to submit a complete and accurate UST Response Plan OV OR o COS <br /> 2634(e) <br /> 106 CCR 2632 (d) , 2641 (h) Failure to submit and maintain a current facility plot plan / site map o V ❑ R o COS <br /> 107 HSC 25292.2; CCR Failure to submit and maintain complete and current financial responsibility documents o V OR o COS <br /> 2711 (a) (11 ) <br /> 108 CCR 2620(b) ; HSC Failure to implement or maintain a written agreement between the UST owner and operator o V OR o COS <br /> 25284(a) (3) <br /> 109 CCR 2715(a) (1 )(6) , Failure to submit " Designated Underground Storage Tank Operator Identification Form" within 30 days o V o R o COS <br /> 2715(a) (3) <br /> 110 CCR 2715(a) (1 ) (A) , Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form" o V o R o COS <br /> 2715(a)(2) <br /> 111 CCR 2637 , 2638(e), Failed to notify the EHD 48 hours prior to conducting testing n V o R o COS <br /> 2643(g) <br /> 112 CCR 2638, 26410) , Failure to have properly qualified service technician test leak detection equipment every 12 months o V o R c COS <br /> 2715 (f) <br /> 113 CCR 2637(a-d), 2712(b) Failure to conduct secondary containment testing o V o R o COS <br /> ( 1 ) (F) <br /> 114 CCR 2636(0 (3) , 2643(c) Failure to perform line integrity test every 12 months or within 30 days of repair of primary pipe o V ❑ R o COS <br /> (3) <br /> 115 CCR 2638 (c) , 2638(d) Failure to submit "Monitoring System Certification Form" within 30 days of completion of the test o V o R ❑ COS <br /> 116 CCR 2637 . 1 (d) , Failure to submit the "Spill Container Testing Report Form" within 30 days o V o R o COS <br /> 2637 . 1 (e) <br /> 117 CCR 2637(e) , 2637(f) Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test o V o R o COS <br /> 118 CCR 2637.2(d&e) , Failure to submit the "Overfill Prevention Equipment Inspection Report Form" within 30 days o V o R o COS <br /> 2665(a&b) <br /> 119 CCR 2663, 2712(b) (6) Failure to comply with tank lining certification, testing , inspection, and record requirements o V o R o COS <br /> 120 CCR 2631 , 2640. 1 , Failure to submit and/or maintain documentation regarding compatibility for UST system components o V o R o COS <br /> 2665, 2711 <br /> PR0231989 <br /> Page 1 of 4 Underground Storage Tank rogram OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464-0138 1 www. sjgov. org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.