Laserfiche WebLink
bp <br /> YOSEMITE <br /> AVE <br /> KEY LEGEND EXISTING OFFSITE <br /> IRRIGATION TO REMAIN <br /> EMITTER/BUBBLER SCHEDULE <br /> DEDICATED 3/4"IRRIGATION WATER METER (See Civil drawings) <br /> • POINT OF CONNECTION (Coordinate with owner's representative) LOW WATER USE <br /> 1" FEBCO 825Y REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER (INSTALLED BY OTHERS) 15 GAL. TREES <br /> BF WITH A SECURED FREEZE PROTECTION BLANKET. (INSTALL WILKINS 500 1-RAINBIRD 1402 BUBBLER IN RWS(.5 GPM) o <br /> PRESSURE REGULATOR ON DOWN SIDE OF DEVICE FOR STATIC PRESSURE HIGHER THAN 75 PSI) 4-.5 GPH (AGRIFIM) "gas K C <br /> C IRRITROL RAINDIAL(RD600--EXT-R) EXTERIOR CONTROLLER 5 GAL.SHRUBS <br /> 2-.5 GPH (AGRIFIM) <br /> ® IRRITROL CL-100-WIRELESS WEATHER SENSOR AND MODULE 1 GAL SHRUBS <br /> RAINBIRD 33DLRC 3/4"QUICK COUPLING VALVE. 1-.5 GPH (AGRIFIM) <br /> RAINBIRD PEB REMOTE CONTROL VALVE (SIZE PER PLAN) W/LINE SIZE SPEARS ISOLATION BALL VALVE <br /> RAINBIRD 1"XCZ-100-PRF CONTROL ZONE W/LINE SIZE SPEARS ISOLATION BALL VALVE MEDIUM WATER USE <br /> 15 GAL. TREES <br /> WATTS BRASS FULL PORT BALL VALVE (LINE SIZE) WITH TEFLON SEAT, 1-RAINBIRD 1404 BUBBLER IN RWS(1 GPM) <br /> PVC SCH.40 SLEEVE (2x THE DIAMETER OF PIPE(S) AND 1"FOR CONTROL 4-.5 GPH (AGRIFIM) <br /> -71 <br /> WIRES OR AS SPECIFIED ON PLAN) 5 GAL.SHRUBS NORTH <br /> a � <br /> ®®® SCH.40 PVC MAIN LINE ( 1-1/4"OR AS OTHERWISE NOTED) 2-1 GPH (AGRIFIM) nO <br /> 1 GAL SHRUBS �� ? <br /> SCH.40 PVC LATERAL (3/4"OR AS OTHERWISE NOTED) 1- 1 GPH (AGRIFIM) <br /> ® RAINDBIRD 1400 SERIES BUBBLER (see bubbler schedule,this sheet) VINES GST ���, <br /> ® 6 32 48 feet <br /> .700 POLYETHEYLENE DRIP TUBING WITH FLUSHING END CAP <br /> 2-1 GPH (AGRIFIM) ® ® /�� E N� <br /> (TUBING TO BE STAKED 3 O.C. &MAX. LENGTH OF TUBING TO NOT EXCEED 100 LF) <br /> ® P.V.C.TO POLYTUBING CONNECTION *PLANT WATER USE CLASSIFICATIONS CAN BE VIEWED ON SHEET Ll El 18215 72ND AVENUE SOUTH <br /> 1" = 16' KENT, WA9 32 <br /> (425)251-6222 <br /> (425)251-8782 FAX <br /> WXW(� CIVIL ENGINEEM, LMD PILMNING, <br /> VALVE CALLOUT ® {( IICANWY / ® AL <br /> l�9 NM DAA <br /> •- Valve Number Q <br /> 3 <br /> #" # Valve Flow <br /> in <br /> Valve Size <br /> w <br /> GENERAL IRRIGATION NOTES <br /> Uj <br /> 1. LOCATE ALL IRRIGATION EQUIPMENT IN LANDSCAPE PLANTERS. EQUIPMENT SHOWN IN PAVEMENT AND OFFSITE IS FOR CLARITY ONLY. <br /> ALL VALVE BOXES SHALL BE LOCATED AT LEAST 2'FROM ANY PAVEMENT. I t <br /> 2. DRIP IRRIGATION TUBING LAYOUT AS SHOWN ON PLAN IS CONCEPTUAL. ACTUAL 1/2'TUBING LENGTHS SHALL NOT EXCEED 100 LINEAR P <br /> FEET FROM POINT OF CONNECTION AT RIGID SCHEDULE 40 PVC. 3 <br /> w <br /> 3. IRRIGATION SLEEVES AS INDICATED ON LEGEND SHALL BE INSTALLED AT ALL PAVEMENT/HARDSCAPE CROSSINGS. <br /> 4. CONTACT USA NORTH (81 1) PRIOR TO COMMENCING CONSTRUCTION TO VERIFY EXISTING UNDERGROUND UTILITIES. <br /> IRR GATION LEEVE <br /> 5. EXISTING MATURE OFFSITE LANDSCAPE IRRIGATION (BY OTHERS)SHALL REMAIN PROTECTED IN PLACE. <br /> 1" LEEVE F R IRE( P.) n eaccalos�." `+g <br /> No. 442 , <br /> It <br /> jkt <br /> MODEL WATER EFFICIENT LANDSCAPE ORDINANCE <br /> / 2 <br /> Water Efficient Landscape Worksheet ETAF Calculations / 1�„ '" 6 ROD SCACCALOSI <br /> Regular Landscape Areas / 4 LANDSCAPE ARCHITECT <br /> HYDROZONE/PLANTING PLANT IRRIG. IRRIG. ETAF LANDSCAPE ETAF ESTIMATED TOTAL 1 1 <br /> DESCRIPTION FACTOR METHOD EFFICIENCY (PF/IE) AREA x AREA WATER USE Total ETAF x Area (g) 1 139 Bp M PO Box 2083/ <br /> (PF} (IE) (Sq. Ft.) (ETWU) / <br /> $ Petaluma CA 94952 <br /> REGULAR LANDSCAPE AREA Total Area (A) 2,832 / 707-280-8990 <br /> Avera e ETAF (B/A) .40 a IRRIGATION METER <br /> g OliveStreetLandscape.com <br /> LOW WATER USE PLANTS .3 DRIP .81 .37 2,467 913 30,737 GAL. 3 2 rscac@sbcglobal.net <br /> Note: Q ATA BE <br /> DEVELOPMENT INFOWA71ION: <br /> MEDIUM WATER USE PLANTS .5 DRIP .81 .62 365 226 7,609 GAL. 1. Average ETAF for Regular Landscape APO® STI <br /> Areas must be below.55 for residential <br /> TOTALS (A) 2,832 (B) 1,139 areas and .45 for non-residential areas. 4 3000 am/pm <br /> EJ <br /> ETWU Total 38,346 GAL. 0 <br /> rs, 5 FUEL CANOPY <br /> 0 <br /> Maximum Applied Water Allowance (MAWA). MAWA= (ETo) (Conversion factor) ((ETAF)(Landscal2e Area))+ ((1-ETAF)xSLA) F� w/ 6 MPD's <br /> (54.3) (.62) (.45 x 2,832) + (1-.45) X 0) =42,904 GALLONS 9�,f C R <br /> Estimated Total Water use (ETWU). ETWU= (ETo)) (Conversion factor) ((ETAF) (Area)) <br /> (54.3) (.62) (1,139) =38,346 GALLONS SM ADDRES& <br /> EXISTING OFFSITE EXISTING OFFSITE ESCAL®N AVENUE <br /> IRRIGATION TO REMAIN IRRIGATION TO REMAIN ®HMWAY 120 <br /> ` ESCALON,CA <br /> REFERENCE NOTES SCHEDULE � <br /> SYMBOL DESCRIPTION DETAIL FACILITY # TBD <br /> 2 Point of connection (POC) @ 3/4"meter. Irrigation demand at POC shall be 8 GPM and a static pressure of 60 DEEM W. AUL4=ZMW <br /> PSI. If minimum requirements are not met contact Landscape Architect. OEM W. 6P RERk <br /> DMVM or. ALKWE Rh <br /> 3 Backflow Prevention Device to be installed at deicated 3/4"Irrigation Meter. Install Wilkins pressure regulator on down <br /> side of device for pressure readings that exceed 75 PSI. <br /> 17223 <br /> 4 Install irrigation controller at building wall or per client representative. 120 Power to be provided by others. Coordinate 1n�: <br /> actual location with client representative and General Contractor prior to beginning irrigation work. DRAYM <br /> 5 Install wireless weather sensor within distance as specified by manufacturer. Rain sensor location shall be free from any IRRIGATION <br /> overhead obstruction. PLAN <br />