CUENT:
<br /> SECUMTY TES GENERAL NOTES
<br /> REQUIRED EQUIPMENT A. ALL DIMENSIONS SHOWN ON REFLECTED CEILING PLAN ARE FROM
<br /> bo
<br /> Q Q FINISHED FACE UNLESS NOTED OTHERWISE.
<br /> 20" COLOR PUBLIC VIEW MONITOR SHOULD BE CEILING MOUNTED AT THE ENTRANCE OF
<br /> STORE. AS THE CUSTOMER ENTERS THE FACILITY, THE IMAGE SHOULD BE READILY SEEN. B. REFER TO ELECTRICAL LIGHTING PLAN FOR LIGHTING SPECIFICATIONS j
<br /> II AND FIXTURE MOUNTING HEIGHTS.
<br /> 0 A MINIMUM OF 15" COLOR MONITOR SHOULD BE PLACED IN THE BACK OFFICE FOR
<br /> VIEWING AND MONITORING.
<br /> © WHERE BACK OFFICE SPACE IS LIMITED, A SMALLER COLOR MONITOR MAY BE C. REFER TO SYMBOL j'D FOR ALL CEILING HEIGHTS ON PLAN.
<br /> APPROPRIATE.
<br /> 0 ROBOT/SENSORMATIC COLOR (16 PORT) MULTIPLEXER. SUSPENDED COUNG •OTE ;
<br /> 0 APPROVED TIME LAPSE VIDEO RECORDER (BEST RESULTS ARE OBTAINED IN 24-HOUR
<br /> —————————————————————— I I RECORDING MODE). 1. SUSPENDED CEILING SYSTEM MUST BE HEAVY DUTY SYSTEM
<br /> - 0 24-HOUR REAL TIME AUDIO RECORDING (RECORDED ON 24-HOUR VIDEO TAPE). CONFORMING TO ASTM C 635, ASTM C 636, AND IN ACCORDANCE
<br /> - 0 APPROVED SECURE CABINET FOR RECORDING EQUIPMENT. NORTHWEST WALL & CEILING BUREAU TECHNICAL BULLETIN NO. 401.
<br /> 0 A MINIMUM OF FIVE-COLOR VIDEO CAMERAS WITH PROPER LENSES MOUNTED IN-STORE.
<br /> \\ 0 A MINIMUM OF TWO EXTERIOR MOUNTED CAMERAS WITH ENVIRONMENTAL HOUSINGS TO 2. SUSPENDED MEMBER GRID MUST BE ATTACHED TO TWO ADJACENT
<br /> 89_0)1 COVER OPERATIONS AT THE FUELING ISLANDS. WALLS ON MINIMUM 2" WIDE WALL MOLDINGS OR CLOSURE ANGLES
<br /> 0 FACILITIES WITH CASH ACCEPTING PIC UNITS MUST HAVE CAMERA COVERAGE FOR EACH AT THESE WALLS.
<br /> OPERABLE SIDE OF THE UNIT. IF A SINGLE CAMERA CANNOT VIEW BOTH SIDES OF A
<br /> _ DUAL� UNIT, THEN ADDITIONAL CAMERAS MUST BE INSTALLED TO COMPLETE COVERAGE. 3. ENDS OF SUSPENDED MEMBER MAIN RUNNERS AND CROSS RUNNERS
<br /> OPTIONAL VIDEO EQUIPMENT MUST BE TIED TOGETHER TO PREVENT DISLOCATION.
<br /> 8'-0" 0 ADDITIONAL VIDEO CAMERAS (INTERIOR AND EXTERIOR). 4. LIGHT FIXTURES 101bs. TO
<br /> %-R20'-O" �B� 0 13" COLOR MONITOR SHOULD BE CEILING MOUNTED NEAR CASH REGISTER AREA. 55TIN WEIGHT MUST BE SUPPORTED
<br /> 'p7 Ra MONITOR MUST SEQUENCE THE EXTERIOR CAMERA IMAGES AND MUST BE READILY TO STRUCTURE BY AT LEAST TWO X12 GAUGE HANGER WIRES, EACH
<br /> �1py VIEWED BY CASHIER. AT TWO OPPOSING SIDES, AND SHALL BE ATTACHED TO SUSPENDED ARCO
<br /> 0 INTERACTIVE AUDIO/VIDEO MONITORING SERVICE PROVIDED BY APPROVED VENDOR FOR MEMBER GRID AT TWO OPPOSING SIDES. WIRES MAY BE SLACK.
<br /> %�N
<br /> 24-HOUR INTERACTIVE OFF-FACILITY SECURITY MONITORING SERVICE. BP WEST COAST PRODUCTS,LLC5. HVAC TERMINALS OR REGISTERS 201bs. TO 561bs. IN WEIGHT SHALL
<br /> OPTIONAL DIGITAL RECORDER REQUIREMENTS BE POSITIVELY ATTACHED TO SUSPENDED MEMBER MAIN RUNNERS,
<br /> — — 0 DIGITAL CCTV RECORDING SYSTEM: SUFFICIENT HARD DRIVE SPACE TO SUPPORT 12 OR TO CROSS RUNNERS WITH EQUAL CARRYING CAPACITY, AND
<br /> 84n 269-219/ COLOR CAMERAS AT 5% FRAMES PER SECOND, PER CAMERA, FOR 31 DAYS. MUST ALSO BE SUPPORTED TO STRUCTURE BY AT LEAST TWO X12
<br /> 4 I 0 AUDIO RECORDING IS REQUIRED AT THE SALES COUNTER AREA. GAUGE HANGER WIRES AT TWOOPPOSING SIDES. WIRES MAY BE
<br /> 22'-62" ..
<br /> 0 AN AUDIO PROCESSING KIT (LOUROE PREFERRED) IS REQUIRED TO SYNCHRONIZE THE SLACK.
<br /> 8'-0" AUDIO WITH THE VIDEO IMAGE.
<br /> 6. EMT CONDUIT - SIZE AND LENGTHS: 1/2" EMT CONDUIT - UP TO
<br /> T NOTE: 5-10"•' 3/4" EMT CONDUIT - UP TO 7'-8"•Y 1" EMT CONDUIT -
<br /> 7
<br /> —— ALL CAMERA AND MONITOR LOCATIONS TO BE CONFIRMED WITH OWNER OR SECURITY UP TO g'-9" OR METAL STUDS - SIZE ANDLENGTH: SINGLE 1%"
<br /> R13, VENDER PRIOR TO INSTALLATION. ADDITIONAL MONITOR AT CASHIER AREA OR CAMERAS n
<br /> -s- p METAL STUD (20GA) - UP TO 12'-0
<br /> MAY BE REQUIRED
<br /> KEYED NOTES
<br /> --
<br /> - - 1 0'-7j"
<br /> G ENG
<br /> I 2'-11 " 2'-4 " _ ELECTRICAL CONTRACTOR SHALL VERIFY THE FOLLOWING PRIOR TO O INSTALL SECURITY MONITOR
<br /> INSTALLING NEW EMERGENCY LIGHTING AND PROVIDE THIS INFORMATION ON2 ROOF HATCH LADDER
<br /> 0
<br /> 1 - 18215 72ND AVENUE SOUTH
<br /> THEIR PERMIT SUBMITTAL PLANS:
<br /> EMERGENCY LIGHTING SHALL BE ARRANGED TO PROVIDE AN INITIAL BULKHEAD FRAMING KENT, WA 98032
<br /> I
<br /> ILLUMINATION THAT IS AT LEAST AVERAGE OF 1 FOOT-CANDLE ANDA (425)251-6222
<br /> MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE MEASURED ALONG THE PATH O OPEN WEB TRUSSES, REFER TO STRUCTURAL PLANS (425)251-8782 FAX
<br /> OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED
<br /> TO DECLINE TO 0.6 FOOT-CANDLES AVERAGE AND A MINIMUM AT ANY 5STEEL CANOPY, REFER TO STRUCTURAL PLANS CIVIL ENGINEERING, LAND PLANNING,
<br /> POINT OF 0.06 FOOT-CANDLES AT THE END OF THE EMERGENCY LIGHTING SURVEYING, ENVIRONMENTAL SERVICES
<br /> 02 �T LAYOUT TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY RATIO O AIR CURTAIN, REFER TO MECHANICAL PLANS
<br /> OF 40:1 SHALL NOT BE EXCEEDED. No. DATE REVISION DESCRIPTION
<br /> SCALE: 1/4"=1'-O" EMERGENCY POWER SYSTEM SHALL BE PROVIDED FOR A DURATION OF O CANOPY DOWNSPOUTS, REFER TO CIVIL PLANS FOR CONTINUATION
<br /> 09/98/96 euiLDiNc PERIL SUBMITTAL
<br /> NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES,
<br /> UNIT EQUIPMENT, OR AN ON-SITE GENERATOR. EXTERIOR WALL SIGNS, UNDER SEPARATE PERMIT
<br /> 1 99 »
<br /> 6'-102 6'- (D
<br /> 102 6'-102" 6'-102'° Id, 9 PROVIDE BLOCKING AND ELECTRICAL FOR DISPLAY MONITORS z
<br /> 4'-102" 4'-102" 4'-10199 4'-101- o s
<br /> WOOD TRUSSES, REFER TO STRUCTURAL PLANS
<br /> -- _-T-.__ -.- HIMSH AMD MATEMAL SYMBOLS 0
<br /> _ -- L_ s
<br /> s9'-611 PANT COLOR (SEMI-GLOSS REQUIRED OVER ALL FOOD SERVICE AREAS AND RESTROOM)
<br /> �N
<br /> UTILITY I ( GB-2 in P-3 DUNN EDWARDS DEC756, "WEATHERED BROWN", HIGH GLOSSFICEQ
<br /> bN -
<br /> 9'-6, DUNN EDWARDS, DEC748, "OYSTER", EGGSHELL FINISH
<br /> . .. 0
<br /> EM 2 P-5 DUNN EDWARDS DEW380, "WHITE", EGGSHELL FINISH 1
<br /> 3REP
<br /> P-6 DUNN EDWARDS, DEA138, "INDIGO NIGHT", EGGSHELL FINISH SEAt
<br /> s
<br /> CT 1II GB71. .
<br /> MATERIAL bN WALK
<br /> o CA
<br /> � �� - ------ ---------- ---- -------
<br /> II
<br /> a-
<br /> 0 •• (� .. - CT 1 WASHABLE SUSPENDED CEILING TILE ,��' DANIEL BRIAN ?
<br /> MTL-1 USG 3270 "CLIMA VINYL", n n " `, la. GOALWIN v
<br /> co • . ' .. / 9 PLUS INYL , 24 x48 (WHITE)
<br /> _ .. ..-. •-. , :- •. A Q. .R• •..:..:•:.••. .-•' ..'.. .....:.:: ; ..:.':.. .' - ACOUSTICAL SUSPENSION SYSTEM F,
<br /> 7$-8"± .
<br /> II
<br /> • \\� >^ 9 n � �C-18865
<br /> - DONN, DX, �s EXPOSED TEE SYSTEM (WHITE) \
<br /> . . . . . . . 5 " 1 •REN. 8/39/17
<br /> II EM.. 9 -0
<br /> GYPSUM BOARD, SMOOTH FINISH
<br /> /
<br /> P-4 P-4 P-4 \ - �/_ \ GB-2 %" MOISTURE RESISTANT GYPSUM BOARD, SMOOTH FINISH AR
<br /> GB-2 GB-2 l.. . . . _ .
<br /> \..
<br /> 9 n , y9 \ PLY-1 PLYWOOD, REFER TO STRUCTURAL FOR SPECIFICATION
<br /> 10 -6
<br /> H.
<br /> P-4 MTL-1 STUCCO-GALVALU M, REFER TO Q1.2 SHEET
<br /> GB-2 ;. ..
<br /> I'
<br /> P_4 I 8''•=0"' MTL-2 22GA PRE-FINISHED ROLLED ROOFING PANELS,
<br /> ( I - II 3" HIGH RIB ® 16" O.C. REFER TO SPECIFICATION SHEET.
<br /> GB-2
<br /> 10'-6 '•.�.'' : EM ,' .:. STUCCO EXTERIOR STUCCO FINISH INSTALLED PER MANUF SPECS
<br /> I :
<br /> GB-1 II —
<br /> CMUG LEGENDSAS —
<br /> DEVELOPMENT INFORMATION:
<br /> 10 -6
<br /> (EM) - DENOTES EMERGENCY BACKUP LIGHTING
<br /> II P-4 u == ARC �
<br /> �
<br /> GB-2 I CLEARSTORY P-4 12,9 LED HIGH BAY FIXTURE MOUNTED 10'-6" A.F.F.
<br /> P-4 I P-4 ( PLY-1 I' : :. HA
<br /> �
<br /> '-0" LWAY '..:. • - .. I I 3000 a tm/pEr"I(tl
<br /> I. 8PLY-1 B
<br /> G -1 149
<br /> L I 2'x2' LED RECESSED PANEL FIXTURE [FUEL CANOPY
<br /> i 4 i
<br /> 21'± I . :. O. :.. GB_2 Q wi 6 PD's
<br /> ,. . . —
<br /> A 0 LED RECESSED DOWNLIGHT FIXTURE
<br /> G1 6D
<br /> ?=< SITE ADDRESS:
<br /> LED PENDANT FIXTURE
<br /> bN EM P-4 I I oTyp. O : . : :.: ESCAL AVENUE
<br /> n •• •. ,
<br /> I." 10 -0 5;C LED SURFACE MOUNTED COOLER FIXTURE
<br /> I. 120
<br /> GB-2 EBCAL®(el�C6�
<br /> P-4 P-4 ±. .'
<br /> ' GB-1 LED EXTERIOR SURFACE MOUNTED AWNING FIXTURE ® MTL AWNING
<br /> —®— �.. FACILITY TBD
<br /> — —— FLUSH MOUNTED ® STUCCO SOFFITS
<br /> ®� " 6 10'-6" - _ Esc
<br /> P .4 � "
<br /> GB 2 D ED BY: AWANCEzap:
<br /> FREEZER ( � d LED EXTERIOR WALL MOUNTED FIXTURE
<br /> 8.-©n -4-I:.
<br /> F. —— LJ: CHECKED®Y RP REPM:
<br /> ' EM: .
<br /> DRAVN BY: ALLIANCE PM:
<br /> EM ` " — ————— _ — O— DIRECTIONAL WALL MOUNTED FIXTURE
<br /> MTL-1 I L : • Q ------———— ———
<br /> ON RO
<br /> T
<br /> Zo 7, 819¢ I ( 17223
<br /> • 70-
<br /> ekERP EXIT SIGN / EMERGENCY LIGHTING
<br /> . RAVANG TITLE.
<br /> • .,::999.9 : •.
<br /> ' ■ SECURITY MONITOR [REFLECTED
<br /> 49-41" 4P-41" 5 4'-42" 4'-42" SECURITY CAMERA
<br /> fi
<br /> e.11
<br /> P-4 P-4 5 SHEET NO:
<br /> 6'-102" 6'-102" STUCCO 9 1n1„
<br /> 5 STUCCO 6 -102 6'-102 OVERHEAD WALL RECEPTACLES
<br /> 1'-011 C 01 P-3
<br /> MR=
<br /> A3.1 4 A3.2 MTL-2
<br /> 01 REFLECTED CEUNG PL 1'-0" FE] EXHAUST FAN
<br /> SCALE: 1/4"=1'-0" FE-11 HOOD EXHAUST FAN Al
<br /> e
<br />
|