Laserfiche WebLink
i <br />I- - <br />A k- <br />S <br />TRAP AT RISER (TYP.) <br />01 <br />L <br />-C- - I - -C- L -c- -� _C_ -� <br />II <br />TRAP LEAVING REFRIGERATED ROOM <br />EVAPORATION PIPING SYSTEM <br />SCALE: N/A <br />COOLER DIMENSION PLAN <br />SCALE: 1/4"=1'-0" <br />LEGEND <br />---S--- SUCTION <br />----L---- LIQUID <br />- - - - C- - - - CONDENSATE DRAIN <br />NOTE: <br />ALL SUCTION LINES TO BE INSULATED <br />CU -2 <br />L <br />S - <br />ROOF <br />L <br />S <br />TRAP AT RISER (TYP.) <br />L -c-� <br />II <br />TRAP LEAVING REFRIGERATED ROOM <br />EVAPORATOR COILS <br />0 <br />BOX LOAD <br />REQUIREMENTS <br />QTY. <br />HEATCRAFT <br />MODEL # <br />FANS <br />REFG. <br />TMR E <br />REFG. <br />LBS. <br />B.T.U.'S <br />1 HR. <br />EACH <br />POWER <br />SUPPLY <br />BOX <br />TEMP. <br />F <br />DEFROST <br />HEATER <br />FAN <br />MOTOR <br />AC <br />EACH <br />CFM <br />MCA <br />MCA <br />CU -1 <br />COOLER <br />40,034 BTU/H <br />4 <br />LCA6110AB <br />2 <br />1,300 <br />404A <br />-- <br />9,400 <br />208/230/1/60 <br />+34 <br />7.8 <br />2.0 <br />MOH031 L63C <br />LL 2 <br />REACH -IN FREEZER <br />2,132 BTU/H <br />1 <br />LCE694BB <br />1 <br />335 <br />404A <br />-- <br />2,800 <br />208/230/1/60 <br />-15 <br />5.7 <br />1.2 <br />BP REPM: <br />CONDENSING UNITS <br />0 <br />BOX LOAD <br />REQUIREMENTS <br />QTY- <br />HEATCRAFT <br />MODEL # <br />SUCTION <br />TEMP. <br />REFG. <br />TYPE <br />R <br />REFG. <br />CHG. <br />LBS, <br />B T.U.'S <br />HR <br />EACH <br />POWER <br />SUPPLY <br />DEFROST <br />TIMER <br />MIN <br />CCT. <br />AMP. <br />MAX. <br />FUSE <br />SIZE <br />COOLER <br />40,034 BTU/H <br />1 <br />MOH03OX63C <br />+25' <br />404A20.0 <br />®21000AM6 <br />208/230/3/60 <br />ELECTRIC <br />38.0 <br />40 <br />DANIEL BRIAN <br />CU 2 <br />FREEZERN <br />2,132 BTU/H <br />1 <br />MOH031 L63C <br />-20' <br />404A <br />5.5 <br />3 281 0110' AMB. <br />208/230/3/60 <br />ELECTRIC <br />15.0 <br />25 <br />@ SCOTT CREEK DRIVE <br />CODES AND STANDARDS <br />NSF STANDARDS: COMPLY WITH APPLICABLE NATIONAL SANITATION <br />FOUNDATION (NSF) STANDARDS AND RECOMMENDED CRITERIA. PROVIDE <br />EACH PRINCIPAL ITEM OF FOOD SERVICE EQUIPMENT WITH A NSF <br />SEAL OF APPROVAL" <br />UL LABEL: WHERE AVAILABLE, PROVIDE UL LABELS ON PRIME <br />ELECTRICAL COMPONENTS OF FOOD SERVICE EQUIPMENT. PROVIDE <br />UL "RECOGNIZED MARKING" ON OTHER ITEMS WITH ELECTRICAL <br />COMPONENTS SIGNIFYING LISTING BY UL, WHERE AVAILABLE. <br />HEALTH CODE: INSTALL FOOD SERVICE EQUIPMENT IN ACCORDANCE <br />WITH LOCAL HEALTH DEPARTMENT APPLICABLE REGULATIONS, <br />1. SHOP DRAWINGS UPON APPROVAL OF BID, SUBMIT 3 SETS OF <br />COMPLETE DETAILS, MECHANICAL AND ELECTRICAL REQUIREMENTS, <br />AND INSTALLATION INSTRUCTIONS OF EACH ITEM. INCLUDE INFORMATION <br />ON ROUGHING IN DIMENSIONS, SERVICE CONNECTION REQUIREMENTS, <br />OPENINGS, DISPLAY AND LATCH DOOR MANUFACTURER'S INFORMATION, <br />COMPLETE FLOOR PLANS AND EQUIPMENT SPECIFICATIONS. <br />2. TAKE FIELD MEASUREMENTS TO ASSURE ACCURATE FIT OF FABRICATED <br />EQUIPMENT. <br />3. INCLUDE WARRANTY INFORMATION ON ALL EQUIPMENT. <br />COOLER/FREEZER ALARMS <br />COOLER/FREEZER ALARMS AS MANUFACTURED BY: <br />NATIONAL CONTROLS CORPORATION <br />1725 WESTERN DRIVE <br />WEST CHICAGO, IL. 60185 <br />(800) 323-2593 <br />PROVIDE THE FOLLOWING: <br />(1) DUAL KIT #TNC-TM100-KT2A <br />KIT INCLUDES: <br />• 2 THERMOMETER UNITS <br />• 1 TEMPERATURE PROBES WITH 6'-0" WIRE <br />• 1 TRANSFORMER <br />• 1 STAINLESS STEEL TWIN ENCLOSURE <br />ADDITIONAL PROBE WIRE #X02-22GNO-820 <br />INSTALLATION: <br />*INSTALL THERMOMETER UNITS IN CASHIER AREA. <br />*INSTALL TEMPERATURE PROBE IN EACH RESPECTIVE COOLER/FREEZER <br />COMPARTMENT. SPLICE THE 6'-0" PROBE WIRE WITH ADDITIONAL <br />PROBE WIRE AS REQUIRED TO RETURN TO CASHIER AREA. <br />• COMPLETELY SEAL ANY AND ALL INTRUSIONS TO COOLER/FREEZER <br />COMPARTMENTS. <br />• LABEL ALL THERMOMETER UNITS PER RESPECTIVE COOLER/FREEZER <br />COMPARTMENTS. <br />• SET ALARM TEMPERATURE AS FOLLOWS: <br />• WALK-IN COOLER: +35' F. <br />• WALK-IN FREEZER: 0' F. <br />• LOCATE TEMP. PROBES A MIN 2'-0" FROM WALL AND 5'-0" FROM DOOR. <br />WALK-IN COOLER NOTES <br />1.0 GENERAL NOTES - <br />1.1 WALK-IN COOLER SHALL BE PREFABRICATED METAL CLAD PANELS <br />BY CUSTOM COOLERS INC. OR EQUAL. DESIGNED IN MODULAR <br />CONCEPT TO FACILITATE ACCURATE JOB SITE ASSEMBLY. <br />2.0 PANEL CONSTRUCTION: <br />2.1 ALL PANELS SHALL BE FOAMED -IN-PLACE CLASS 1, POLYURETHANE <br />CONSTRUCTION WITH 3 1/2" COMPOSITE PANEL. THE "R" VALUE TO <br />BE 30 WITH A DENSITY 6F 2.2 POUNDS PER CUBIC FOOT. <br />2.2 THE PERIMETER OF ALL PANELS SHALL BE BUTT JOINT <br />2.3 PANELS TO BE JOINED TOGETHER BY ENGAGING A CAM -ACTION <br />LOCKING DEVICE. THE CAM ACTION DEVICE WILL DRAW THE SECTIONS <br />TOGETHER TO FORM A TIGHT SEAL. <br />2.4 STANDARD PANEL FINISH SHALL BE 26 GAUGE STUCCO EMBOSSED <br />GALVANIZED STEEL SKIN EXTERIOR WITH WHITE INTERIOR. <br />2.5 PROVIDE 7-1/2" DOOR SILL HEIGHTS FOR GLASS DISPLAY DOORS. <br />2.6 INSULATION IS CLASS 1, POLYURETHANE FOAM WITH A FLAME SPREAD <br />LESS THAN 25 AND A SMOKE DEVELOPMENT OF LESS THAN 450. <br />2.7 CERTIFICATIONS: UL AND NSF APPROVED <br />2.8 MEASUREMENTS AND CONFIGURATIONS REFER TO THIS SHEET. <br />3.0 COOLER WALK-IN DOOR <br />MANUFACTURED BY CUSTOM COOLERS, INC. OR EQUAL. <br />3.1 36" x 82" CUSTOM *ANTHONY 103NT (HEAVY DUTY) ALL GLASS <br />PASS-THRU DOOR, SLIMLINE BLACK HANDLE, PRO LEDs, NO <br />THRESHOLD, CYLINDER DOOR LOCK, ALL BLACK FINISH DOOR & FRAME, <br />STAINLESS STEEL INTERIOR/EXTERIOR 10" KICKPLATES. <br />3.2 LOCATION AND SWING AS SHOWN ON THIS SHEET. <br />3.3 FREEZER WALK-IN DOOR <br />MANUFACTURED BY CUSTOM COOLERS, INC. OR EQUAL. <br />3.4 DOOR SHALL BE NOMINAL 3 1/2" FOAMED -IN-PLACE CLASS 1, <br />POLYURETHANE CONSTRUCTION. <br />3.5 DOOR TO BE HINGED, IN -FIT, AND HAVE 36" HIGH DIAMOND PLATE <br />KICK PLATES FOR INTERIOR AND EXTERIOR. <br />3.6 HINGES SHALL BE CAM -RISE WITH BRIGHT SILVER ANODIZED FINISH <br />ON FRAME AND DOOR TRIM, TWO HINGES PER DOOR. <br />3.7 LATCH AND STRIKE TO HAVE A SATIN SURFACE CHROME FINISH WITH <br />PROVISION FOR PADLOCK. LATCH TO HAVE INSIDE SAFETY RELEASE <br />TO PREVENT ENTRAPMENT. <br />3.8 DOOR TO HAVE REPLACEABLE GASKETS FOR A POSITIVE SEAL AND <br />AN ADJUSTABLE VINYL WIPER GASKET FOR SEAL AT DOOR FRAME <br />THRESHOLD. <br />3.9 A FLUSH MOUNTED 2" DIAL THERMOMETER OF CORRECT TEMPERATURE <br />RANGE SHALL BE PROVIDED AT THE DOOR. THE THERMOMETER SHALL <br />BE EASILY CALIBRATED. THE THERMOMETER SENSING BULB ON THE <br />INTERIOR OF THE DOOR SECTION TO HAVE PROTECTIVE COVER. <br />3.10 LIGHTING SHALL CONSIST OF THREE VAPOR -PROOF LIGHT FIXTURES <br />TO BE FURNISHED LOSE, AND A LIGHT SWITCH WITH PILOT LIGHT <br />FLUSH MOUNTED ON EXTERIOR. THE WIRING SYSTEM SHALL BE <br />APPROVED BY UNDERWRITERS LABORATORY. <br />3.11 PROVIDE LOCKS ON DOORS AS INDICATED ON COOLER PLAN. <br />3.12 PROVIDE WALL BUMPER GUARD <br />4.0 GLASS DISPLAY DOORS: <br />MANUFACTURED BY ANTHONY OR EQUAL <br />4.1 30" X 75" H. DISPLAY DOORS (SILL AT 7-1/2" A.F.F.) <br />4.2 ENERGY SAVER CONTROLS <br />4.3 FINISH TO BE SMOOTH BLACK. <br />4.4 COOLER DISPLAY DOORS SHALL HAVE 2 -PANE GAS FILLED NON -HEATED, <br />INSULATED SAFETY GLASS <br />4.5 LED LIGHTING <br />4.6 36" DEEP SHELVES, (7) PER DOOR <br />4.7 KEY CYLINDER LOCK AT EACH DOOR. <br />4.8 COOLER DISPLAY DOORS SHALL HAVE 3 -PANE HEATED SAFETY GLASS <br />5.0 REFRIGERATION• <br />5.1 ALL EQUIPMENT MUST CONFORM TO CONDENSING UNITS AND UNIT <br />COOLERS SCHEDULE AS OUTLINED ON THIS SHEET. EQUIPMENT MUST <br />HAVE UL LISTING FOR THE APPLICATION AS SPECIFIED. <br />5.2 CONDENSING UNIT AS SPECIFIED SHALL HAVE THE FOLLOWING: <br />1. HIGH EFFICIENCY ALUMINUM FIN. COPPER TUBE CONDENSER. <br />2. COMPRESSOR CONTRACTOR. <br />3. HIGH AND LOW PRESSURE CONTROLS <br />4. WEATHER RESISTANT HOUSING WITH WEATHER-PROOF ELECTRICAL <br />CONTROL BOX. <br />5. ACCESS GUARD. <br />6. LOW AMBIENT CONTROL VALVE (CVP II) FPR FLOATING HEAD. <br />7. CRANKCASE HEATER. <br />8. LIQUID LINE FILTER DRIER, SIGHT GLASS AND SERVICE VALVE. <br />9. ELECTRIC DEFROST TIMER. <br />10. EXPANSION VALVES. <br />11. THERMOSTAT AND SOLENOID. <br />5.3 EVAPORATOR COILS SPECIFIED IN EVAPORATOR COIL SCHEDULE. <br />5.4 EXPANSION VALVE SHALL BE SIZED BY UNIT COOLER MANUFACTURER <br />FOR PROPER REFRIGERATION. AS HEAD PRESSURE IS ALLOWED TO <br />DROP DURING LOW AMBIENT CONDITIONS, EXPANSION VALVE NEEDS <br />TO BE OVERSIZED TO ALLOW FLOW AT LOWER PRESSURE DIFFERENTIAL <br />RATIO. <br />5.5 THERMOSTATS SHALL BE FURNISHED LOOSE FOR EACH SYSTEM AND <br />SHALL BE WHITE RODGERS MODEL #1609-101 OR EQUAL, TAMPER -PROOF <br />WITH PROPER TEMPERATURE RANGE, AS REQUIRED ON THIS DRAWING. <br />OPTIONAL MANUFACTURERS: JOHNSON OR RANCO OR EQUAL. <br />5.6 SOLENOIDS SHALL BE FURNISHED LOOSE FOR EACH SYSTEM AS <br />RECOMMENDED BY CONDENSING UNIT MANUFACTURER. <br />5.7 CONDENSATE PIPING SHALL BE COPPER OR PVC AND TRAPPED AFTER <br />WALL PENETRATION. HEAT TAPE AND INSULATE WHERE REQUIRED <br />TO PREVENT FREEZE UP. <br />5.8 REFRIGERATION WARRANTY SHALL BE A MINIMUM OF ONE (1) YEAR PARTS <br />FOUR (4) YEAR COMPRESSOR WARRANTY AND NINETY (90) DAYS SERVICE. <br />5.9 HEAT SENSOR TO BE LOCATED 1'-2" ABOVE DOOR FRAME TO <br />ALLOW FOR GRAPHICS INSTALLATION. <br />6.0 REFRIGERATION INSTALLATION <br />6.1 EVAPORATOR COILS SHALL BE MOUNTED FROM CEILING WITH 5/16" <br />MINIMUM FASTENERS. <br />6.2 CONDENSING UNITS ARE MOUNTED ON THE ROOF AND MUST BE LEVEL <br />WITH IT'S BASE ANCHORED TO PREVENT MOVEMENT. ALLOW PROPER <br />CLEARANCE FOR AIR SUPPLY TO AND FROM UNIT AND FOR PROPER <br />MAINTENANCE ACCESS. <br />6.3 SUCTION LINES AT TOP OF RISER ON ROOF SHALL BE SLOPED 1" PER <br />TEN (10) FEET TO COMPRESSOR. ALL SUCTION LINES SHALL BE SIZED <br />AND TRAPPED. INSULATE TO PREVENT SWEATING. <br />6.4 LIQUID LINES AND SOLENOID VALVE SHOULD BE INSTALLED IN THE <br />LIQUID LINE JUST AHEAD OF EXPANSION VALVE IN COOLER. <br />6.5 BRAZING SHALL BE SILVER BEARING SOLDER HIGH TEMPERATURE OR <br />EQUIVALENT ALLOY SUITABLE FOR THIS APPLICATION. NO "SOFT <br />SOLDERS" PERMISSIBLE. NITROGEN IS TO BE PURGED THROUGH THE <br />SYSTEM DURING BRAZING. <br />6.6 LEAK TEST THE ENTIRE SYSTEM AFTER ALL REFRIGERATION <br />CONNECTIONS HAVE BEEN COMPLETED. LEAK TESTING SHALL BE <br />PERFORMED WITH AN ELECTRONIC LEAK DETECTOR, <br />6.7 THE SYSTEM MUST BE EVACUATED WITH A VACUUM PUMP, HAVING <br />THE CAPABILITY OF PULLING A VACUUM OF 50 MICRONS OR LESS. <br />THE PUMP SHOULD BE CONNECTED TO BOTH THE HIGH AND LOW <br />SIDES OF THE SYSTEM. <br />6.8 DURING CHARGING AND START-UP MAKE SURE SHIPPING RESTRAINTS <br />ARE REMOVED AND ALL ELECTRICAL AND MECHANICAL CONNECTIONS <br />ARE TIGHT. SET HIGH LOW PRESSURE SWITCH AS REQUIRED. <br />6.9 INSTALLATION AND SERVICE OF THIS EQUIPMENT SHOULD BE <br />PERFORMED BY QUALIFIED AND EXPERIENCED REFRIGERATION <br />MECHANICS. INSTALL ALL EQUIPMENT, PIPING IN ACCORDANCE WITH <br />LOCAL AND NATIONAL CODES AND IN CONFORMANCE WITH GOOD <br />PRACTICE REQUIRED FOR PROPER OPERATION. <br />CLIENT: <br />ARCO <br />BP WEST COAST PRODUCTS, LLC <br />18215 72ND AVENUE SOUTH <br />KENT, WA 98032 <br />(425)251-6222 <br />(425)251-8782 FAX <br />CML ENGINEERING, LAND PLANNING, <br />SURVEYING, ENVIRONMENTAL SERVICES <br />NO. I DATE I REVISION DESCRIPTION <br />D5/16/16 BP APPROVED EQUIPMENT PLAN <br />07/13/18 PERMIT SUBMITTAL <br />0 <br />in <br />n <br />a <br />ro <br />N <br />0 <br />E <br />i= <br />0 <br />3 <br />N <br />d <br />0 <br />0 <br />0 <br />U <br />U <br />/ <br />0 <br />O <br />n <br />O <br />N <br />O <br />0 <br />0 <br />L� <br />0 <br />0 <br />zL <br />0 <br />SEAL• <br />OF CAL /FO <br />�2 <br />DANIEL BRIAN <br />09 GOALWIN 7 <br />� o-leass <br />r <br />n REN. 8/31/17 �G <br />F ySep ARC�\C <br />DEVELOPMENT INFORMATION: <br />ARCO NTI <br />MODIFIED <br />3000 am/pm <br />w/ 26'x65' CAR WASH <br />FUEL CANOPY w/ 8 MPD's <br />SITE ADDRESS: <br />TRINITY PARKWAY <br />@ SCOTT CREEK DRIVE <br />STOCKTON,CA <br />FACILITY # TBD <br />DFSGNED BY: <br />MCE ZWIU- <br />CHECKED BY: <br />BP REPM: <br />DRANK BY: <br />ALLIANCE PM: <br />VERSION: <br />PREECT NO: <br />16700 <br />DRAWING TITLE: <br />COOLER <br />PACKAGE <br />SHEET NO: <br />01.2 <br />0 <br />in <br />n <br />a <br />ro <br />N <br />0 <br />E <br />i= <br />0 <br />3 <br />N <br />d <br />0 <br />0 <br />0 <br />U <br />U <br />/ <br />0 <br />O <br />n <br />O <br />N <br />O <br />0 <br />0 <br />L� <br />