Laserfiche WebLink
S A N 0 A Q N Environmental Health Department <br /> � : .o . <br /> . <br /> N I {;: ` COUNTY Jasjit Kang , REHS , Director <br /> OFP Greatness grows here . Muniappa Naidu, REHS , Assistant Director <br /> "9� IFRt� <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Michelle Henry , REHS <br /> Elena Manzo , REHS <br /> February 7 , 2023 <br /> Merlin Bowen <br /> Gettler- Ryan , Inc. <br /> 6805 Sierra Court , Ste G <br /> Dublin , CA 94568 <br /> mbowen ( grinc . com <br /> Re : Arco 02186 SR0086331 <br /> 3212 N California St , Stockton , CA 95204 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to replace on the underground storage tank ( UST) system at the above noted <br /> address . The San Joaquin County Environmental Health Department ( EHD) has completed the review <br /> of the application for a permit to do the following on the underground storage tank ( UST) system at the <br /> above noted address : <br /> • replace the 87 , 87 siphon , 91 spill containers ( in sump) <br /> • replace the 87 , 87 siphon and 91 drop tubes with shut- off valve (flapper) <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust( sigov . org to arrange the following inspection appointments <br /> ( a 4 & hour notice is required for inspection appointments) . <br /> a . Spill bucket test : Verify minimum 5-gallon capacity and pass a one hour hydrostatic test ( or <br /> equivalent) . Proper drainage must also be verified . <br /> b . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume shut <br /> off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> c . Verification that ball float ( s ) , if installed , do not interfere with the installed flapper valve . <br /> Please be aware that the facility cannot receive fuel in the 87 , 87 siphon and 91 tank <br /> prior to the EHD inspection and approval . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 F 209 464 -0138 1 www. sjgov. org/ehd <br />