AC UNIT SCHEDULE <br />FAN SCHEDULE <br />SYMBOL <br />SERVICE <br />LOCATION <br />TYPE <br />MANUFACTURER <br />INDOOR FAN DATA <br />INDOOR COIL DATA <br />2�w <br />COMPRESSOR <br />OUTDOOR <br />GAS FURNACE <br />ROOF <br />ELECTRICAL DATA <br />C 0 0 K " <br />1330 OLYMPIC BOULEVARD, #8 <br />SANTA MONICA, CA. 90404 <br />SYMBOL <br />SERVICE <br />LOCATION <br />TYPEAND <br />LOCATION <br />1 <br />AND MODEL <br />AC -2 <br />- <br />FANq�w� <br />TYPE I <br />a <br />EXHAUST FAN <br />VCR -XP -165 <br />= <br />1.85" <br />CFM <br />ESP <br />FLA <br />HP <br />SENS <br />TOTAL <br />NO <br />RLA <br />LRA <br />FLA <br />INPUTOUTPU <br />A E <br />' <br />�'i1 sJ i <br />FLY <br />STD48-tU <br />2550 <br />MODEL <br />zs <br />o <br />KITCHEN HOOD#2 <br />w� <br />REMARKS <br />MBH <br />TON <br />DRIVE THRU <br />WINDOW <br />AIR CURFLY <br />1 <br />09-25-17 <br />1/6 <br />1 <br />DRAWN BY CHECKED BY <br />FILE NAME <br />MBH <br />�U-)X <br />TYPE I <br />EACH <br />EACH <br />NO <br />EACH <br />MBH <br />MBH <br />q <br />_ <br />V <br />PH <br />HZ <br />MCA <br />MOCP3 <br />PROVIDE GREASE SCOPE AND GREASE COLLECTOR. FAN SHALL BE NFPA 96 APPROVED <br />AC AC <br />KITCHEN <br />ROOF <br />ROOFTOP <br />PACKAGED UNIT <br />" CARRIER " <br />48HJD006 <br />2000 <br />5 <br />PROVIDE VENTILATED ROOF CURB <br />EF <br />ROOF MTD. <br />72 <br />80 <br />CFFM <br />1/8 <br />EXISTING <br />1 2 <br />RESTROOM <br />ROOF <br />EXHAUST FAN <br />ACED-90C15DH <br />200 <br />0.3" <br />- <br />DIRECT <br />- <br />208E60 <br />- <br />30 <br />PROVIDE BACKDRAFT DAMPER <br />57 <br />AC <br />DINING AREA/ <br />RESTROOM <br />ROOF <br />ROOFTOP <br />PACKAGED UNIT <br />CARRIER <br />48HCDD08 <br />3000 <br />0.3 <br />6.9 <br />2.4 <br />89 <br />7 <br />2 <br />13.6 <br />83 <br />2 <br />1.5 <br />125 <br />103 <br />82 <br />800 <br />208 <br />3 <br />60 <br />46 <br />50 <br />12 <br />1400 <br />PPRO TIDE L001 PRRORLE ROOF CURB APPROVED FOR AISR HOOD MIC MOVEMENTS WITH HOLD DOWN CUPS <br />PROOVIDE 77 DAY PROGRAMABLE THERMOSTAT W/ RE TE SENSORS <br />3 <br />- <br />200 <br />PROVIDE BACK DRAFT DAMPER AND ON-OFF SWITCH <br />INTERLOCK WITH EF -1, EF -2, AC -1, AND AC -2 <br />CFM <br />230 <br />PROWDE A/C UNIT WITH CONVENIENT ELECTRIC OUTLET ON ROOF <br />13 <br />IPROVITIF AIR ATH MERV <br />FFIILTER 8 RATING <br />FAN SCHEDULE <br />SYMBOL <br />SERVICE <br />LOCATION <br />TYPE <br />MANUFACTURER AND M OD <br />FAN DATA <br />S.P. <br />CFM IN. W.G. R.P.M. DRIVE <br />MOTOR DATA <br />HP HAS <br />WATTR.P.M. VOLTS HZ FLA <br />WEIGHT <br />LBS <br />REMARKS <br />EF <br />KITCHEN HOOD#1 <br />ROOF <br />GREASE <br />C 0 0 K " <br />1330 OLYMPIC BOULEVARD, #8 <br />SANTA MONICA, CA. 90404 <br />WEIGHT <br />MUA-1 <br />1 <br />SERVICE <br />LOCATION <br />1 <br />AND MODEL <br />AC -2 <br />PROVIDE DISCONNECT SWITCH ON ROOF, INTERLOCK WITH MUA-1, AC -1, AC -2 <br />1 <br />TYPE I <br />800 <br />EXHAUST FAN <br />VCR -XP -165 <br />1100 <br />1.85" <br />- <br />BELT <br />LBS <br />- <br />208 <br />60 <br />- <br />90 <br />PROVIDE GREASE SCOPE AND GREASE COLLECTOR. FAN SHALL BE NFPA 96 APPROVED <br />1/2 <br />1 <br />' <br />�'i1 sJ i <br />FLY <br />STD48-tU <br />2550 <br />PROVIDE VENTILATED ROOF CURB <br />EF <br />KITCHEN HOOD#2 <br />ROOF <br />GREASE <br />" C 0 0 K " <br />LOCATION <br />DRIVE THRU <br />WINDOW <br />AIR CURFLY <br />1 <br />09-25-17 <br />1/6 <br />1 <br />DRAWN BY CHECKED BY <br />FILE NAME <br />PROVIDE DISCONNECT SWITCH ON ROOF, INTERLOCK WITH MUA-1, AC -1, AC -2 <br />2 <br />TYPE I <br />EXHAUST FAN <br />VCR -XP -165 <br />850 <br />3.0" <br />- <br />BELT <br />_ <br />- <br />208 <br />80 <br />- <br />90 <br />PROVIDE GREASE SCOPE AND GREASE COLLECTOR. FAN SHALL BE NFPA 96 APPROVED <br />PROVIDE VENTILATED ROOF CURB <br />EF <br />ROOF MTD. <br />C 0 0 K <br />1/8 <br />3 <br />RESTROOM <br />ROOF <br />EXHAUST FAN <br />ACED-90C15DH <br />200 <br />0.3" <br />- <br />DIRECT <br />- <br />208E60 <br />- <br />30 <br />PROVIDE BACKDRAFT DAMPER <br />FAN SHALL INTERLOCKED WITH AC -1 <br />UA <br />KITCHEN <br />ROOF <br />ROOF MTD. <br />F" CHAMPION <br />0.5" <br />1/3 <br />1 <br />EVAPORATIVE COOLER <br />3000E <br />1150 <br />- <br />BELT <br />- <br />120 <br />- <br />200 <br />PROVIDE BACK DRAFT DAMPER AND ON-OFF SWITCH <br />INTERLOCK WITH EF -1, EF -2, AC -1, AND AC -2 <br />AIR CURTAIN SCHEDULE <br />TYPE I HOOD <br />LIST OF COOKING EQUIPMENT UNDER HOOD "i": <br />HOOD SIZE 7'-7" X 3'-7" <br />1. BROILER <br />HOOD NO. 1 PROVIDED � 1100 CFM ETL LISTED <br />EXHAUST AIR <br />PROVIDED 1100 CFM (EF -1) <br />DUCT SIZE 1. 10"0 <br />DUCT AIR <br />VELOCITY - 1 20DFP <br />MAKE-UP AIR <br />PROVIDED - 1100 CFM(MUA-1 AND <br />TRANSFER FROM DINING <br />GREASE FILTER & HOOD AREA) <br />PRESSURE LOSS 1.0" S.P. <br />(MINUS DUCT) <br />HOOD 1 <br />SCALE <br />HOOD "I" CALCULATION NONE <br />TYPE I HOOD <br />LIST OF COOKING EQUIPMENT UNDER HOOD "2": <br />HOOD SIZE 5'-7" X 3'-2" <br />1. FRYER <br />HOOD NO. 2 PROVIDED � 850 CFM ETL LISTED HOOD <br />EXHAUST AIR <br />PROVIDED 850 CFM (EF -2) <br />DUCT SIZE - 1. 10"0 <br />DUCT AIR <br />VELOCITY <br />MAKE-UP AIR <br />PROVIDED - 800 CFM(MUA-1 AND <br />TRANSFER FROM DINING <br />GREASE FILTER & HOOD AREA) <br />PRESSURE LOSS 1.05" S.P. <br />(MINUS DUCT) <br />HOOD 2 <br />SCALE <br />HOOD "2" CALCULATION NONE <br />AIR <br />BALANCE <br />SCHEDULE <br />UNIT NUMBER <br />OUTSIDE AIR EXHAUST AIR <br />MAX AIRFLOW <br />MOTOR DATA <br />1100 <br />EF -2 <br />- <br />850 <br />EF -3 <br />- <br />MANUFACTURER <br />1330 OLYMPIC BOULEVARD, #8 <br />SANTA MONICA, CA. 90404 <br />WEIGHT <br />MUA-1 <br />SYMBOL <br />SERVICE <br />LOCATION <br />TYPE <br />AND MODEL <br />AC -2 <br />HAS <br />- <br />REMARKS <br />800 <br />- <br />TOTAL <br />2350 <br />2150 <br />CFM <br />HP R.P.M. VOLTS HZ FLA <br />LBS <br />1FKITCHEN <br />DOOR <br />WALL <br />AIR CURTAIN <br />" MARS " <br />1/2 <br />1 <br />' <br />�'i1 sJ i <br />FLY <br />STD48-tU <br />2550 <br />_ <br />120 <br />60 <br />5.1 <br />125 <br />PROVIDE AUTO DOOR SWITCH <br />LOCATION <br />DRIVE THRU <br />WINDOW <br />AIR CURFLY <br />" MARS1 <br />09-25-17 <br />1/6 <br />170805 <br />DRAWN BY CHECKED BY <br />FILE NAME <br />EQUIPMENT SCHEDULE <br />AND NOTES <br />M-1 <br />FANTAIN <br />LPN272 <br />1800 <br />_ <br />120 <br />60 <br />2.6 <br />58 <br />PROVIDE AUTO DOOR SWITCH <br />TYPE I HOOD <br />LIST OF COOKING EQUIPMENT UNDER HOOD "i": <br />HOOD SIZE 7'-7" X 3'-7" <br />1. BROILER <br />HOOD NO. 1 PROVIDED � 1100 CFM ETL LISTED <br />EXHAUST AIR <br />PROVIDED 1100 CFM (EF -1) <br />DUCT SIZE 1. 10"0 <br />DUCT AIR <br />VELOCITY - 1 20DFP <br />MAKE-UP AIR <br />PROVIDED - 1100 CFM(MUA-1 AND <br />TRANSFER FROM DINING <br />GREASE FILTER & HOOD AREA) <br />PRESSURE LOSS 1.0" S.P. <br />(MINUS DUCT) <br />HOOD 1 <br />SCALE <br />HOOD "I" CALCULATION NONE <br />TYPE I HOOD <br />LIST OF COOKING EQUIPMENT UNDER HOOD "2": <br />HOOD SIZE 5'-7" X 3'-2" <br />1. FRYER <br />HOOD NO. 2 PROVIDED � 850 CFM ETL LISTED HOOD <br />EXHAUST AIR <br />PROVIDED 850 CFM (EF -2) <br />DUCT SIZE - 1. 10"0 <br />DUCT AIR <br />VELOCITY <br />MAKE-UP AIR <br />PROVIDED - 800 CFM(MUA-1 AND <br />TRANSFER FROM DINING <br />GREASE FILTER & HOOD AREA) <br />PRESSURE LOSS 1.05" S.P. <br />(MINUS DUCT) <br />HOOD 2 <br />SCALE <br />HOOD "2" CALCULATION NONE <br />AIR <br />BALANCE <br />SCHEDULE <br />UNIT NUMBER <br />OUTSIDE AIR EXHAUST AIR <br />EF -1 <br />- <br />1100 <br />EF -2 <br />- <br />850 <br />EF -3 <br />- <br />200 <br />1330 OLYMPIC BOULEVARD, #8 <br />SANTA MONICA, CA. 90404 <br />TEL: (310) 452-0575 <br />MUA-1 <br />1150 <br />- <br />AC -1 <br />200 <br />- <br />AC -2 <br />200 <br />- <br />AC -3 <br />800 <br />- <br />TOTAL <br />2350 <br />2150 <br />RESTAURANT POSITIVE PRESSURE <br />2350 - 2150 = 200 <br />KITCHEN EXHAUST NOTES <br />1- DUCT BRACING AND SUPPORTS SHALL BE OF NONCOMBUSTIBLE MATERIAL, <br />BOLTS , SCREWS, RIVETS, AND OTHER MECHANICAL FASTENERS SHALL NOT <br />PENETRATE DUCT WALLS. <br />JOINTS AND SEAMS SHALL BE MADE WITH CONTINUOUS WELD OR BRAZE MADE <br />ON THE EXTERNAL SURFACE OF THE DUCT. <br />2- DUCTS SERVING A TYPE 1 HOOD SHALL BE SO CONSTRUCTED TO AVOID <br />GREASE POCKET , THE DUCT SYSTEM SHALL HAVE MINIMUM 1/4" SLOPE <br />TOWARD HOOD OR GREASE COLLECTING DEVICE; PROVIDE CLEAN OUT DOOR <br />IF DUCT ON HORIZONTAL ANGLE AND FIRE RESISTANT ACCESS DOOR TO <br />SHAFT ENCLOSURE. <br />3- AIR VELOCITY WITHIN TYPE 1 HOOD EXHAUST DUCT SHALL BE 500 TO 2500 <br />FPM. <br />4- PROVIDE MINIMUM OF 6" CLEARANCE BETWEEN TYPE 1 <br />HOOD DUCT AND FIRE RATED ENCLOSURE. <br />5- EXHAUST OUTLETS OF BOTTOM HORIZONTAL CENTRIFUGAL FANS SHALL BE MIN. <br />2 FT. ABOVE THE ROOF. EXHAUST OUTLETS SERVING GREASE DUCT SYSTEMS <br />AND POWER ROOF VENTILATORS FOR RESTAURANT COOKING APPLIANCES SHALL <br />BE 40 INCHES ABOVE ROOF SURFACE, 10 FT. FROM PROPERTY LINE, 10 FT. <br />FROM AIR INTAKE OPENINGS AND 10 FT. ABOVE ADJOINING GRADE, <br />10 FT. FROM BUILDING STRUCTURE AND/OR PARAPETS <br />6- THE FIRE -EXTINGUISHING SYSTEM SHALL BE INTERCONNECTED TO THE FUEL AN <br />OR CURRENT SUPPLY SO THAT THE FUEL OR CURRENT IS AUTOMATICALLY <br />SHUTT OFF TO ALL EQUIPMENT UNDER THE HOOD WHEN THE SYSTEM IS <br />ACTUATED. INSTALL AN AUTOMATIC FIRE SPRINKLER SYSTEM WHENEVER THE <br />BUILDING IS FULLY SPRINKLERED. ACCESS DOORS ARE REQUIRED FOR SERVICE <br />AND REPLACEMENT AT EACH SPRINKLER. <br />7- PROVIDE AT LEAST ONE PORTABLE FIRE EXTINGUISHER WITH A RATING OF <br />NOT LESS THAN 108C FOR KITCHEN AREA. <br />GENERAL NOTES <br />MECHANICAL DESIGN IS BASED ON 2016 CALIFORNIA MECHANICAL CODE. <br />ALL DUCTS TO COMPLY WITH 2016 CMC. <br />ALL TRANSVERSE JOINTS TO BE SEALED <br />WITH TAPE OR MASTIC. ALL LOW PRESSURE DUCT WORK SIZED EQUAL TO OR LESS <br />THAN 0.1"W.G./100 FT. <br />INSTALLATION OF DUCT WORK SHALL BE COORDINATED WITH ALL OTHER <br />TRADES. <br />PROVIDE MASTIC OR DUCT TAPE JOINT SEALANT TO SEAL TRANSVERSE <br />JOINTS ON AIR SUPPLY DUCTS INSTALLED IN LOCATIONS WHERE AIR <br />LEAKAGE THROUGH THE JOINTS WOULD BE NONBENEFICIAL TO THE <br />OCCUPIED AREA TEMPERATURE REQUIREMENTS. AND , SEAL LONGITUDINAL <br />JOINTS ON LOW PRESSURE SUPPLY DUCTS WHERE INTERNAL STATIC PRESSURE <br />EXCEED 0.75" OF WATER COLUMN. <br />EQUIPMENT AND DUCT WORK EXPOSED TO WEATHER TO BE WEATHERPROOF. <br />VERIFY WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR EXACT <br />LOCATION OF DUCT OPENINGS ON ROOF <br />ALL WORKS SHALL COMPLY WITH REQUIREMENTS OF ALL APPLICABLE CODES <br />LAWS ORDINANCES AND REGULATIONS OF ALL AUTHORITIES HAVING <br />JURISDICTION. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS <br />PLAN CHECK FEES, INSPECTIONS, ETC. AND FURNISH SIGNED, CERTIFIED AND <br />ACCEPTABLE COPIES TO THE OWNER FOR HIS RECORD. <br />TOILET EXHAUST FAN DUCTS SHALL BE OF SMOOTH, NON-ABSORBENT AND <br />NON-COMBUSTIBLE SURFACE MATERIAL <br />ALL OSA INTAKES MUST BE A MINIMUM OF 10'-0" AWAY FROM TOILET OR <br />KITCHEN HOOD EXHAUST DISCHARGE, PLUMBING OR APPLIANCE VENT (OR 3' -0 - <br />MINIMUM BELOW VENT). <br />MANUAL VOLUME DAMPER OR ADJUSTABLE EXTRACTORS TO BE INSTALLED IN <br />ALL BRANCH TAKE -OFFS. ALL DAMPERS TO HAVE LOCKING QUADRANTS. <br />ALL AIR CONDITIONING UNITS TO BE FURNISHED WITH MAINTENANCE MANUALS, <br />SCHEDULES AND TAGS <br />ALL LOW VOLTAGE WIRING SHALL CONFORM MECHANICAL SECTION <br />THE MECHANICAL CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, APPARATUS <br />ACCESSORIES (I.E. THE ENTIRE INSTALLATION) AS FURNISHED BY HIM FOR A <br />PERIOD OF ONE YEAR. <br />THE MECHANICAL CONTRACTOR SHALL OBTAIN & PAY FOR ALL PERMITS, <br />LICENSES & INSPECTIONS REQUIRED FOR THIS JOB. <br />COORDINATE THE SIZE, LOCATION AND SERVICE REQUIREMENTS OF ALL <br />MECHANICAL EQUIPMENT & DUCTWORK WITH THE GENERAL, PLUMBING, ELEC. <br />CONTROL & FIRE PROTECTION CONTRACTOR PRIOR TO THE START OF <br />CONSTRUCTION. REPORT ALL UNSOLVED CONFLICTS TO THE OWNER. <br />COORDINATE THE LOCATION OF ALL CEILING DIFFUSERS, REGISTERS, GRILLES <br />& ETC. WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. <br />FLEXIBLE CONNECTIONS SHALL BE PROVIDED FOR ALL DUCTWORK ATTACHED <br />TO AIR MOVING EQUIPMENT MOUNTED VISERATION ISOLATORS AND OR <br />SUSPENDED FROM VIBRATION HANGERS. <br />THE ELECTRICAL AND PLUMBING CONTRACTORS SHALL PROVIDE FLEXIBLE <br />CONNECTIONS AT ALL MECHANICAL EQUIPMENT MOUNTED ON VIBRATION <br />ISOLATORS AND OR SUSPENDED FROM VIBRATION HANGERS. <br />ALL CONDENSATE DRAIN LINES RUNNING INSIDE BUILDING SPACES SHALL <br />BE INSULATED WITH JOHN'S-MANVIL "AEROTUBE" TYPE PREFORMED SNAP-ON <br />PLASTIC INSULATION. <br />PROVIDE ALL FIRE AND SMOKE DAMPERS AS REQUIRED BY LEGALLY <br />CONSTITUTED AUTHORITIES AND CODES HAVING JURISDICTION. <br />PAINT PLENUM BEHIND EACH GRILLE OR REGISTER WITH FLAT BLACK PAINT <br />BALANCE AND ADJUST ALL DIFFUSERS ,REGISTER, ETC. FOR OPTIMUM AIR <br />DISTRIBUTION AND MINIMUM NOISE. SUBMIT A CERTIFIED AIR BALANCE <br />REPORT TO THE MECHANICAL ENGINEER FOR APPROVAL BALANCING OF THE <br />SYSTEMS SHALL BE PERFORMED BY AN INDEPENDENT TEST & BALANCING <br />AGENCY WHICH SPECIALIZES IN THE BALANCING & TESTING OF HEATING <br />VENTILATING AND AIR CONDITIONING SYSTEMS. <br />ALL AIR CONDITIONING FILTERS SHALL BE REPLACED ON DAY OF BALANCING <br />PRIOR TO TESTING. <br />ALL EXPOSED AIR DISTRIBUTION SYSTEM (DUCTWORK, CD, CRR, ETC.) SHALL BE <br />PAINTED AS PER PLAN OR DIRECTED BY ARCHITECT. <br />CONTRACTOR TO VISIT THE JOB & INFORM OWNER OF ANY PROBLEMS OR <br />DISCREPANCY BEFORE STARTING THE JOB. <br />LABEL AIR CONDITIONING UNITS OR DEVICES WITH SPACE NAME AND NUMBER <br />ALL HORIZONTAL DUCTS AT SOFFIT AREA SHALL BE INSIDE THE SOFFIT. <br />ALL EXPOSED DUCTWORK SHALL BE AS CLOSE TO WALLS & ROOF DECK AS POSIBLE. <br />PROVIDE ALL TRASITIONS AS REQUIRED FROM MAIN DUCT OR BRANCHES TO DIFFUSERS <br />OR REGISTERS OR GRILLES <br />ALL DIFFUSERS AND REGISTERS SHALL BE INSTALLED AS HIGH AS POSSIBLE. <br />ALL NEW DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE. <br />GENERAL CONTRACTOR <br />PROVIDE ALL NECESSARY EQUIPMENT CURBS, RUNNERS AND PLATFORMS. <br />PROVIDE ALL NECESSARY ROOFING, PATCHING, CUTTING, RATED SHAFTS, <br />FURRING, FLASHING AND PAINTING. <br />PLUMBING CONTRACTOR <br />PROVIDE ALL NECESSARY DRAINS, GAS, CONDENSATE DRAINS WITH TRAPS, <br />MAKE-UP WATER, INCLUDING FINAL CONNECTIONS. <br />ELECTRICAL CONTRACTOR <br />FURNISH AND INSTALL ALL LINE VOLT. WIRING, ALL CONDUITS AND <br />AUXILIARIES AS SHOWN ON PLANS. <br />LEGEND <br />ISYMBOLI DESCRIPTION II SYMBOL I DESCRIPTION <br />I `I SUPPLY AIR DUCT II P.O.C. Q� I POINT OF CONNECTION <br />® RETURN AIR DUCT _FD FIRE DAMPER <br />ILII OUTSIDE AIR DUCT II H I EQUIP. DESIGNATION <br />DUCT II SD ET -I SMOKE DETECTOR <br />- - <br />I LINED DUCT <br />I UTR <br />JUP TO ROOF <br />y- <br />FLEXIBLE CONNEC. <br />TR <br />TOP REGISTER <br />-� <br />MAN. VOLUME DAMP. <br />TG <br />TOP GRILLE <br />CR I CEILING REGISTER II -U/D I UNDERCUT DOOR <br />CD I CEILING DIFFUSER I I CO ICO2 SENSOR <br />I U I THERMOSTAT II !q I REMOTE SENSOR <br />s <br />y- <br />r <br />ARMET DAVIS NEWLOVE & <br />ASSOCIATES, AIA ARCHITECTS <br />1330 OLYMPIC BLVD. <br />SANTA MONICA, CALIFORNIA 90404 <br />PH 310 452-5533 FAX 310 450-4742 <br />L & D ENGINEERING <br />ENERGY & MECHANICAL SYSTEM CONSULTANT <br />1330 OLYMPIC BOULEVARD, #8 <br />SANTA MONICA, CA. 90404 <br />TEL: (310) 452-0575 <br />FAX: (310) 450-4742 <br />EMAIL: KAVEH®LAN DDENGINEERING.COM <br />REV. DATE DESCRIPTION <br />CONTMCFDR IS RESPONSIBLE FOR REVIEW OF ALL POIRIONS OF <br />THE CONSTRUCTION DOCUMENFS AND SIALL VERIFY ALL DIMENSIONS <br />AND EIISRNG CONDRIONS PRIOR TO SUBMISSION OF BIDS. THE <br />CONTMCTOR SHALL NOTFY THE DESIGNER'S OFFICE IMMEDIATELY OF <br />ANY DISCREPANCIES, INCONSISTENCIES OR OMISSIONS PRIOR TO <br />COMMENCEMENT OF ANY WORK, AND AWN THE DESIGNER'S <br />CI?RIFIGRON WHERE APPIJGBLE. SUBMIT ALL NECESSARY SHOP <br />DRAWINGS TO THE DESIGNER'S OFFICE FOR APPROVAL OF DESIGN <br />COMPI ANCE PRIOR TO FABRICATION. <br />ALL IDEAS, DESIGNS AND SPECIFICATIONS REPRESENTED BY THESE <br />DRAWINGS PRE AND SHALL REMNN THE PROPERTY OF L & D <br />ENGINEERING, INC. NONE OF THESE IDM OR DESIGNS SHALL BE <br />USED OR ��??ISCLOSED TO ANYONE FOR ANY PURPOSE, NOR <br />REPRODUCER, COPIED, ADAPTED OR DISTRIBUTED, WITHOUT THE <br />01"MISSION <br />WRITTEN OF L & D ENGINEERING, INC. <br />COPYRIGHT C L & D ENGINEERING, INC. 2005 <br />ry <br />' <br />�'i1 sJ i <br />AGE <br />I G <br />LOCATION <br />BURGER KING <br />7847 TAM O'SHANTER DR. <br />STOCKTON, CA 95210 <br />DATE <br />09-25-17 <br />JOB NO. <br />170805 <br />DRAWN BY CHECKED BY <br />FILE NAME <br />EQUIPMENT SCHEDULE <br />AND NOTES <br />M-1 <br />