REVISIONS <br /> CW PIPE IN WALL IFP 04.05.2022 <br /> STU D WALL <br /> 1/2" SOV <br /> � 7, <br /> SLOPE PIPING AS MUCH TRAP PRIMER <br /> AS POSSIBLE TOWARD SECURE TO STUD <br /> DISCHARGE, TYPICAL CONNECT TO CW <br /> ACCESS PANEL PIPE IN WALL <br /> INDIRECT WASTE 2" VENT RISER Q O Lo <br /> PIPING �� IN WALL UNION U �'p <br /> FINISHED 1/2" CW PIPE CIO O <br /> FIN. FLOORz <br /> MIN 2" FLOOR FLOOR DRAIN OR O O <br /> °. . FLOOR SINK CD 0 N <br /> ° ROUTE PIPING INCONSPICUOUSLY z �I <br /> � I <br /> ° AND UNOBTRUSIVELY. HANG PIPE � `O <br /> ° . .° <br /> AS REQUIRED. DO NOT INSULATE@) 01 <br /> FLOOR SINK INDIRECT DRAIN PIPE WHEN EX— WASTE LINE (SI I I z <br /> POSED IN FOOD SERVICE FACILITY. PER PLAN) I I E <br /> 2" "P" TRAP 2 WATER TIGHT SEAL AD <br /> 1/2" CW BELOW FLOOR <br /> 1/2" CW TO TRAP <br /> CONNECT AS REQ'D * No. 67047 <br /> FLOOR SINK DETAIL RIMER T DRAIN ��9 Exp�9v30�2022�� <br /> TRAP P O FLOOR lF OF CAS-�F� <br /> 6 1 <br /> NTS NTS <br /> CONTRACTOR TO CONFIRM AND INFORM THE STRUCTURAL ENGINEER <br /> PRIOR TO ANY CUTTING IF THE (E) SLAB IS POST TENSION TYPE. <br /> #3 REBAR 20" STAGGER <br /> ON EACH SIDE, TYP. <br /> 1 " H&CW, SEE PLANS <br /> #3 REBAR FOR CONTINUATION <br /> DOWELED TO A MIN OF 6" 5/8" CONDENSATE CONNECTION. <br /> (E) CONCRETE SLAB 12" MIN 12" MIN IN (E) FLOOR SLAB. BOND CONNECT TO DRAIN LINE AND <br /> (E) VAPOR BARRIER WITH EPDXY. TYP. ROUTE TO MOP SINK. 3" SUPPLY & RETURN VENT PER <br /> (E) DRAIN ROCK FINISHED FLOOR MANUFACTURER RECOMMENDATIONS. <br /> 1 " BALL VALVE IN SEE HVAC PLANS. <br /> ACCESSIBLE LOCATION <br /> a a a a <br /> a a a a THERMOMETER SUPPLY, <br /> UPPLY, SEE <br /> SN <br /> ATURAL GAS <br /> O O O O O O O O O O 2 GALLON THERMAL EXPANSION <br /> TANK WITH NSF LINER. AGA RATED GAS VALVE IN <br /> I I II ACCESSIBLE LOCATION <br /> ASME RATED TEMPERATURE & <br /> I EXTEND REQ RELIEFVALVE. <br /> ADISCHARGE <br /> I I I I — TO SPILL INTO MOP SINK TANKLESS WATER HEATER <br /> (E) NATIVE SOIL — I I I I I I I I I _ SECURE TO WALL PER <br /> T MANUFACTURER'S RECOMMENDATIONS <br /> 3/4" DRAIN VALVE , UNION (TYP X 3) w <br /> TRENCH BACKFILL SHALL BE MOISTURE CONDITIONED OVERLAP NEW VAPOR BARRIER ' _ I 8" LONG CAPPED w <br /> TO AT LEAST 5% OVER OPTIMUM MOISTURE CONTENT FOR A MINIMUM OF 6" ON BOTH - —J DIRT LEG <br /> AND COMPACTED TO 85-90% RELATIVE COMPACTION SIDES WITH (E) VAPOR BARRIER <br /> PER ASTM D1557 WITH STEGO WRAP TAPE. TYP. <br /> U) <br /> Z <br /> TYP. SLAB CUT/POUR BACK DETAIL GAS FIRED WATER HEATER DETAIL Q0 <br /> 8 2 CL Q <br /> NTS NTS O <br /> O 0� <br /> ROOF V w <br /> o z <br /> PIPE WITHOUT UNIONS OR Z J O <br /> 5/8" GYP. WALL W/ S/S VALVES IN CEILING SPACE Q [-- M <br /> G WALL LINER, TYP. = z LO <br /> 000000 o Q Q <br /> GAS LOCK OR SHUT OFF — _ � U <br /> — LAY IN CEILING O <br /> WATER HEATER GWH 1 D GAS PIPE SIZED PER <br /> MANUF'R SPECIFICATIONS <br /> GAS PIPING DOWN IN WALL � O U <br /> PIPE WITHOUT UNIONS OR _ Q <br /> FLEXIBLE GAS LINE TO EQUIP., VALVES co <br /> SIZED PER MFG. SPECIFICATION. O N <br /> ALLOW ENOUGH SLACK LINE TO co <br /> PULL EQUIP. 24" MIN. FROM <br /> WALL, TYP. DATE 04/01/2022 <br /> FLEXIBLE APPLIANCE <br /> JOB 2227 <br /> STORAGE SHELF CONNECTOR. TYPICAL 6" <br /> f— A DIRT LEG TO SHEET TITLE <br /> MOP HOOK u C ABOVE . PLUMBING <br /> FLOOR DETAILS <br /> MANUAL GAS VALVE, APPROVED PROVIDE LINE SIZED <br /> RESTAINING CABLE A k FLEXIBLE GAS PIPING, AND QUICK APPROVED GAS PIPING TEE <br /> DISCONNECT MOUNTED IN ON CONCEALED PIPING IN <br /> ACCESSIBLE LOCATION BEHIND WALL, FOR APPLIANCE <br /> 1 EQUIPMENT. CONNECTION. <br /> MOP SINK ELEVATION 7 GAS EQUIPMENT CONNECTION DETAIL GAS EQUIPMENT CONNECTION DETAIL SHEET 4 3 <br /> NTS NTS NTS P3 " 0 <br />