GENERAL NOTES <br /> 1). ALL WORKS SHALL COMPLY WITH THE CURRENT CALIF. BUILDING OCCUPANCY LOAD CALCULATIONS ,o a`" co San Joaquin County REVISIONS <br /> CODES AND ALL CURRENT LOCAL GOVERNING CODES, REGULATIONS r y Environmental Health Department RAMEN 101 RESTAURANT B <br /> AND ORDINANCES. y < 1868 E. Hazelton Ave. y <br /> DESCRIPTION AREA OCCUPANT LOAD FACTOR OCCUPANTS Stockton, CA 95205 <br /> 2). CONTRACTOR SHALL BE LICENSED, FULLY INSURED AND EXPERIENCED R��rtoR�'�P (209) 468-3420 zi� <br /> IN LOCAL CONSTRUCTION PRACTICE, CODES AND REGULATIONS. A DINING AREA 270 SQ. FT. 15 18 2162 DANIELS ST MANTECA CA 95337 <br /> 3). CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS B KITCHEN 583 SQ. FT. 200 3 APPROVED WITH CONDITIONS <br /> PRIOR TO COMMENCEMENT OF WORK. NO WORK SHALL BE STARTED - <br /> UNTIL ALL QUESTIONS AND DISCREPANCIES ARE RESOLVED. C RESTROOM 103 SQ. FT. 100 For conditions, please see approval letter dated: 4-19-22 TENANT IMPROVEMENT <br /> 4). CONTRACTOR SHALL EXAMINE ALL RELEVANT PLANS, SPECIFICATIONS TOTAL OCCUPANCY = 21 Approved by: Gl9/ wly Date: Apr 19, 2022 <br /> AND OTHER CONSTRUCTION DOCUMENTS PRIOR TO COMMENCEMENT <br /> OF WORK. ANY OMISSIONS OR DISCREPANCIES IN ANY PART OF THE <br /> CONSTRUCTION DOCUMENTS SHALL BE REPORTED TO OWNER PRIOR <br /> TO COMMENCEMENT OF WORK. SCALE SHALL NOT BE USED FOR r <br /> DETERMINING EXACT DIMENSIONS. <br /> 5). WORK SHALL BE DONE IN ACCORDANCE WITH PLANS STAMPED BY <br /> DEPARTMENT OF BUILDING INSPECTION. OWNER SHALL BE INFORMED <br /> IMMEDIATELY IF DIFFERENT SOLUTION IS NECESSARY. FAILURE TO DO SO <br /> SHALL PUT ENTIRE RESPONSIBILITY ONTO CONTRACTOR. _ - <br /> Is 5r da+trels st <br /> 6). CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR SAFETY OF PEOPLE OM <br /> Daniels StL �` Dantels5t + <br /> AND PROPERTY ON THE PROJECT SITE. CONTRACTOR SHALL CAREFULLY Daniels St 0 { <br /> CHECK THE STABILITY OF TALL EXISTING ELEMENTS PRIOR TO CONSTRUCTION. Hibbett Sports <br /> Shoe store <br /> ALL WORK SHALL BE DONE IN ACCORDANCE WITH CALOSHA REQUIREMENTS. LLLLLLLLL LLLLLLLLLLKohl's <br /> LLLLLLLLL <br /> ALL POWER EQUIPMENT SHALL BE OPERATED ONLY UNDER THE APROVAL OFLLLLLLLLLL <br /> Gepartrnents:ore Ross oma° <br /> LLLLLLLLLLLLLLLLLLL Clothin <br /> THE GOVERNING AGENCIES. FIRE EXTINGUISHER SHALL BE PROVIDED AND LLLLLLLLL a, <br /> LLLLLLLLL Wolf Lodge Water <br /> MAINTAINED DURING CONSTRUCTION. LLLLLLLLL P Q <br /> LLLLLLLLL 9 Costco Wholesale <br /> LLLLLLLLL orthern California Warehouse sore <br /> LL LLLLLL <br /> Stadium Dental Grp U <br /> LL LLL <br /> 7). CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AT HIS/HER OWN LL LL LLL Costco Tire Center and orthodontics z O <br /> LLL LLL Stadium Center O <br /> LLLLLLLLL Tire shop p U <br /> EXPENSE. ANY DAMAGE TO ANY PUBLIC OR PRIVATE PROPERTY THAT IS LLLLLLLLL Shopping mall u <br /> LLLLLLLLL <br /> LLLLLLLLL <br /> CAUSED BY HIS/HER WORK. LLLLLLLLL � O <br /> LLLLLLLLL <br /> LLLLLLLLL <br /> LLLLLLLLL Ulta Beauty w = <br /> LLLLLLLLL <br /> LLLLLLLLL Cosmetics store U) � <br /> LLLLLLLLL vJ <br /> LLLLLLLLL <br /> LLLLLLLLL r M �1 <br /> 8. ALL MATERIALS, FIXTURES, EQUIPMENT SHALL BE NEW AND UNUSED. Chili's Grill& B LL.I H M <br /> NO SUBSTITUTION SHALL BE MAKE WITHOUT OWNER'S AUTHORIZATION. j jj % Q Trx r.�ee • Z <br /> ITEMS WHICH ARE NOT SPECIFIED BY TYPE OR MANUFACTURES SHALL Costco Gas Station // (D CO r-- <br /> BE <br /> BE OF AVERAGE QUALITY UNLESS APROVED BY OWNER. / ,' ,' Manteca watershed ��f (n w Lu <br /> i <br /> by Costco �'~ W w o <br /> PROJECT DATA <br /> co uj <br /> VICINITY MAP <br /> � Q = Q <br /> Cf) Lu0 <br /> N <br /> 1). PROJECT ADDRESS: 2162 DANIELS ST MANTECA CA 95337 °; <br /> 2). OCCUPANCY GROUP: GROUP B KEY FOR FLOOR PLAN AREA <br /> NOTE FOR FIRE DEPARTMENT: <br /> 3). BUILDING TYPE: VB ALL INTERIOR FINISH MATERIALS INCLUDING HANGINGS, DRAPES, <br /> 4). TOTAL AREA: 956 SQ. FT. DROPS, FLOORING TRIM AND BASE SHALL BE HAVE A FLAME INDEX <br /> LESS THAN 25 AND SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450 <br /> 5). OCCUPANCY LOAD: 21 DEFERRED ITEMS REQUIRING SEPARATE NOTE FOR WALK-IN: <br /> 6). FORMER USAGE: HAIR CUT PERMITS: FOAM PLASTIC INSTALLED IN A MAX THICKNESS OF 10" IN COOLER AND FREEZER WALLS SHALL: Q co <br /> LO <br /> 1. THE WALK-IN SHALL BE HAVE A FLAME SPREAD INDEX OF 25 OR LESS AND A SMOKE-DEVELOPED INDEX OF NOT rn <br /> 7). PROPOSE BUSINESS: RAMEN RESTAURANTMORE THAN 450. WHERE TESTED IN A MIN 4" THICKNESS. U <br /> 1). AUTO-FIRE SPRINKLER & FIRE ALARM SYSTEM 2. HAVE FLASH IGNITION AND SELF-IGNITION TEMPERATURES OF NOT LESS THAN 600°F AND 800° F RESPECTIVELY. Q <br /> 8). AUTO SPRINKLER: YES 3. HAVE A COVERING OF NOT LESS THAN 0.032" ALUMINUM OR CORROSION-RESISTSANT STEEL HAVING A BASE W <br /> 9). ACCESSIBLE PARKING: YES 2) HOOD ANSUL SUPPRESSION SYSTEM METAL THICKNESS NOT LESS THAN 0.0160" AT ANY POINT. (n Z <br /> 4. BE PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION SECTION 903.3.1.1. W <br /> WHERE THE COOLER OR FREEZER IS WITHIN A BUILDING. BOTH THE COOKER OR FREEZER AND THAT PART OF THE <br /> 10). ELECTRICAL POWER: 120v/208v 200 AMP. 3). OUT DOOR SIGN PERMIT BUILDING IN WHICH IT IS LOCATED SHALL BE SPRINKLERED. r <br /> 11). CODE EDITIONS: W O 0 <br /> 4). ALL DEFERRED SUBMITTED PLAN SHALL BE APPROVED w <br /> THE 2019 CALIFORNIA BUILDING CODE BY CITY OFFICIAL PRIOR TO THE INSTALLATION. PLUMBING FIXTURE REQUIREMENTS:(2019 CPC TABLE 422.1) Z Q <br /> THE 2019 CALIFORNIA PLUMBING CODE W <br /> OCCUPANT LOAD CALCULATION BELOW IS BASED ON THE CALIFORNIA U o <br /> THE 2019 CALIFORNIA MECHANICAL CODE w N <br /> THE 2019 CALIFORNIA ELECTRICAL CODE PLUMBING CODE FOR THE REQUIRED PLUMBING FIXTURE CALCULATION a ro <br /> THE 2019 CALIFORNIA ENERGY CODE(2019 ENERGY EFFICIENCY STANDARDS) 1 . DINING AREA: 270 SQ.FT / 30 = 9 C I <br /> THE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2. KITCHEN AREA: 583 SQ.FT / 2000 = 1 <br /> THE 2019 CALIFORNIA FIRE CODE SCOPE OF WORK: 3. RESTROOM AREA & HALL WAY = N/A <br /> THE 2019 CALIFORNIA CGBC CODE TOTAL OCCUPANTS: = 10 <br /> MAP <br /> THE CONSTRUCTION SHALL MEET ALL THE STANDARD TO DO THE INTERIOR IMPROVEMENT FOR AN RAMEN RESTAURANT. AND USED THE TABLE 422.1 BELOW: SCOPE OF WORK <br /> AND TO MEET THE LOCAL BUILDING CODE & ZONING ORDINANCES. THERE IS ADDED A NEW KITCHEN AND DINING AREA, RELOCATED TABLE 422.1 SHEET INDEX <br /> THE RESTROOM TO THIS PROJECT. NOTES <br /> THE EXISTING A/C UNIT TO BE REMAIN. A-2 For Restaurant minimum plumbing fixtures are: <br /> GENERAL FIRE SAFETY NOTES: THE BUILDING, MECHANICAL,ELECTRICAL& PLUMBING PLAN <br /> WORK IS INCLUDED IN THIS PERMIT APPLICATION. Urinals ��QROFESSIONq, <br /> Water <br /> per <br /> (fixtures �� <br /> Lavatories �`� Q� �'�AO <br /> 1). FRONT DOOR REQUIREMENT: (fixtures person) person) Male and Female <br /> HE FRONT DOOR SHALL HAVE A 10" SMOOTH UNINTERRUPTED SURFACE and No. <br /> ADD NOTE ON TOP OF THE DOOR, STATING "THIS DOOR TO REMAIN UNLOCKED Male Female Male Male Female 6-30-23 <br /> WHEN THE SPACE IS OCCUPIED" WITH 1" MIN. LETTER HEIGHT. SHEET INDEX 1: 1-200 sT clvi� �\P <br /> 1: 1-50 1: 1-25 2: 201-300 1: 1-150 1: 1-150 qTF OF <br /> 2). EXIT DOORS : A-0 VICINITY MAP AND LOT MAP&SIZE GENERAL NOTE AND DATA. 2: 51-150 2: 26-50 3: 301-400 2: 151-200 2: 151-200 <br /> EXIT DOOR SHALL SWING TO THE DIRECTION OF TRAVEL & TO HAVE AN APPROVED PROJECT NOTE SHEET INDEX AND FIRE SAFETY NOTES 3: 151-300 3: 51-100 4: 401-600 3: 201-400 3: 201-400 <br /> PANIC HARDWARE DEVICE AND WITH THE POSTED EXIT SIGN. DEAD BOLTS OR SURFACE A-0.1 EGRESS FLOOR PLAN 4: 301-400 4: 101-200 <br /> MOUNTED LATCHES ARE NOT ALLOWED. INSTALL EMERGENCY POWER FOR LIGHTED 6: 201-300 Designed by : T.W <br /> EXIT AS REQUIRED. (SEE SECTION 1010 OF 2019 CBC) A-1 ACCESSIBLE RESTROOM & DETAILS. FRONT ENTRY DOOR DETAILS 8: 301-400 <br /> A-1.1 SITE MAP & PARKING DETAILS AND NOTE <br /> A-2 (E) FLOOR PLAN & PROPOSED FLOOR PLAN Date : Mar 26, 2022 <br /> 3). ACCESSIBLE SIGNS: A-2.1 LIST OF EQUIPMENT & FINISH SCHEDULE. Over 400, add one fixture for Over 600, add Over 400, add one fixture for <br /> INSTALL THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IN THE FRONT DOOR AREA. each additional 250 males and one fixture for each additional 250 males and <br /> A-3 DETAILS. 1 fixture for each 125 females 300 males 200 females Scale : AS SHOWN <br /> 4). STREET ADDRESS: P-1 PLUMBING NOTES AND CALCULATION. <br /> INSTALL STREET ADDRESS NUMBER NOT LESS THAT 6" HIGH ON A CONTRASTING P-2 WASTE PIPE LAY-OUT <br /> P-3 GAS,HOT-COLD WATER LAY-OUT PROVIDED ONE ALL GENDER FOR THIS PROJECT Drawn : W.P.D. <br /> BACK GROUND AND BE PLAINLY VISIBLE FROM THE STREET OR ROAD FRONTING THE E-I CEILING LIGHTING LAYOUT <br /> PROPERTY E-2 ELECTRICAL POWER LAY-OUT& PANEL DISTRIBUTION <br /> Job <br /> 5). DINING ROOM OCCUPANCY. H-1 HOOD SHEET <br /> EACH DINING ROOM SHALL HAVE AN OCCUPANCY SIGN TO SHOW THE MAXIMUM SEATING. H-2 HOOD SHEET SHEET <br /> H-3 HOOD SHEET <br /> 6). LOCK BOX FOR FIRE MARSHAL: H-4 HOOD SHEET <br /> A KNOX LOCK BOX IS REQUIRED BY FIRE DEPARTMENT. THE EXISTING LOCK BOX M-1 KITCHEN HOOD & MOUNTING DETAILS <br /> LOCATION MAY BE INDICATED ON THE PLAN. CFC 506.1 M-2 ROOF TOP EQUIPMENT LAY-OUT <br /> M-3 MECHANICAL DUCT LAY-OUT <br /> T-24 FOR POWER COMPLIANCE REPORT A=O <br /> T-24.1 FOR POWER COMPLIANCE REPORT <br /> OF SHEETS <br />