Laserfiche WebLink
PI.LD LINE DISABLE SETUP <br /> -- - - - - - - - - - - - E�;R 1 I SLS SETUP <br /> SMARTSENSOR SETUP <br /> Q 1 :87 - - - - - - - -LIQUID SEI[SOR AL1°9S 1 :U7 L I NE EVR TYPE, VACUUM ASSIST <br /> L 3:FUEL ALARM CATEGORY VAC SENSOR VACUUM ASSIST TYPE <br /> L 7:FUEL ALARM PU1°9P #: HEALY VAC <br /> L 6:FUEL ALARM Q 1 :87 <br /> 1. 9:FUEL ALARM VOLUME: 100.0 GALLONS NOZZLE ArL RANGE <br /> L10:FUEL ALARM RELIEF VALUE: : YES MAX: 1 . 15 MIN: 0.95 <br /> L 3:SENSOR OUT ALARM RELIEF VALVE PRESS: <br /> L 7:SENSOR OUT ALARM -9.0 PSI VAPOR PROCESSOR TYPE <br /> L S:SENSOR OUT ALARM NONE <br /> L 9:SENSOR OUT ALARM s 3:91 LINE <br /> L10:SENSOR OUT ALARM CATEGORY VAC SENSOR <br /> L 3:S HORT ALARM PUMP #: ANALYSIS TIMER <br /> L 7:SHORT ALARM Q 2:91 TIME: 10:00 AM <br /> L 8:SHORT ALARM VOLUME: 100.0 GALLONS DELAY MINUTES: I <br /> L 9:2HORT ALARM RELIEF VALVE: : YES <br /> L10:2HORT ALARM RELIEF VALVE PRESS: <br /> -9.0 PSI ACCEPT HIGH ORVR: <br /> PRESSURE LINE LEAK ENABLED <br /> G I :PLLD OPEN ALARM s 4:UENTS 91 STP <br /> CATEGORY VAC SENSOR ISD HOSE TABLE <br /> SMARTSENSOR ALARMS PUMP #: ID FP FL HL AA RR <br /> s 1 :HIGH LIQUID ALARM Q 2:91 -------------------------- <br /> s 5:HIGH LIQUID ALARM VOLUME: 100.0 GALLONS 01 01 01 02 01 00 <br /> RELIEF VALVE: : YES 02 02 02 02 01 00 <br /> ISD SITE ALARMS RELIEF VALVE PRESS: 03 03 03 02 02 00 <br /> ISD GROSS PRES FAIL -9.0 PSI 04 04 04 02 02 00 <br /> IS;D DEGRD PRES FAIL 05 05 05 02 03 00 <br /> ISD VAPOR LEAD FAIL LL 5:VAPOR LINE 07 STP 06 06 06 02 03 00 <br /> ISD SENSOR OUT FAIL CATEGORY VAC SENSOR 07 07 07 02 04 00 <br /> PUMP 4: 08 08 08 02 04 00 <br /> ISD HOSE ALARMS Q 1 :87 <br /> ALL:GROSS COLLECT FAIL VOLUME: 200.0 GALLONS <br /> ALL:DEGRD COLLECT FAIL RELIEF VALVE: : YES ISD AIRFLOW METER MAP <br /> ALL:FLOW COLLECT FAIL RELIEF VALVE PRESS: ID SERIAL NUM LABEL <br /> --9.0 FSI ------------------------ <br /> Q 2:91 l 71169 DISP 1-r' V <br /> s 8:ATMP 2 71152 DISP 3-4 V <br /> LIQUID SENSOR ALMti CATEGORY ATM P SENSOR 3 71128 DISP 5_6, V <br /> L 4:FUEL ALARM y 4 70956 DISP 7-8 V <br /> L 7:FUEL ALARM s 9:DISP 1-2 VFM <br /> L 8:FUEL ALARP9 CATEGORY AIR FLOW METER <br /> L 9:FUEL ALARM IS'D FUEL GRADE HONE MAP <br /> L10:FUEL ALARM s10:DfSP 3-4 VFM 1 9 3 4 <br /> L 4:SENSOR OUT ALARM CATEGORY AIR FLOW METER FP MHH MHH MHH MHH AA <br /> L 7:SENSOR OUT ALARM ------------------------- <br /> L 8:SENSOR OUT ALARM sI1 :DISP 5-6 VFM 01 201 101 901 U U 1 <br /> L 9:SENSOR OUT ALARM CATEGORY AIR FLOW METER 02 202 102 902 U U 1 <br /> L10:SENSOR OUT ALARM 03 203 103 903 U U 2 <br /> L 4:SHORT ALARM 512:DISP 7-8 VFM 04 204 104 904 U U 2 <br /> L 7:SHORT ALARM CATEGORY AIR FLOW METER 05 205 105 905 U LI 3 <br /> L 8:SHORT ALARM 06 206 106 '906 U U 3 <br /> L 9:SHORT ALARM s13:3-4 IDISP VPS 07 207 107 907 U LI 4 <br /> L10:SHORT ALARM CATEGORY VAPOR PRESSURE Ott 209 108 908 U U 4 <br /> PRESSURE LI14E LEAK, <br /> Q 2:PLLD OPEN ALARM LABEL TABLE <br /> -------------------------- <br /> SMARTSENSOR ALARMS 1 : UNASSIGNED <br /> E 3:HIGH LIQUID ALARM 2: BLEND3 <br /> s 4:HIGH LIQUID ALARM 3: REGULAR <br /> ISD SITE ALARMS 4: N1 I D GRADE <br /> PREMIUM <br /> 6. BOLD <br /> ISD GROSS PRES FAIL 5: <br /> GOLD <br /> 12D DEGRD PRES FAIL <br /> I :L: VAPOR LEAK FAIL 7:8: SILVER <br /> ISD SENSOR OUT FAIL 9: BLEND' <br /> 10: BLEND4 <br />