My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:39 AM
Creation date
1/13/2023 9:15:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SETUP _ _ _ - II'J_THI11C SETUP _ - <br /> JAN 19. 21323 8:L5 AM T !:SUPREME <br /> Rte'-232 END OF MESSAGE PRODUCT CODE 000700 <br /> DISHBLED THERMAL COEFF <br /> TANK DIAMETER 92.00 <br /> SYSTEM UNITS AUTO DIAL ALARM SETUP TANK PROFILE 4 FTS <br /> U.S. COMMUNICATIONS SETUP - _ - - - - - - - - - - FULL VOL : 11682 <br /> ti� STEM LANGUAGE - - - - - - - - - 69.o INCH VOL 9577 <br /> ENGLISH D 8:Maintenance 46.0 INCH VOL : 5940 <br /> "!STEM DATE!TIME FORMAT 23.0 INCH VOL : 22_'72 <br /> MOI'! DD YVYY HH:MM:SS xM PORT SETTINGS: IN-TANK ALARMS <br /> h1P1 BOARD 1 {RS-?327 ALL:LEAK ALARM <br /> C51 ALL:HIGH WATER ALARM FLOAT SIZE: 4.0 IN. <br /> 1960 W. 11.TH BAUD RATE 1200 ALL:OVERFILL ALARM <br /> TRACY CA 95376 PARITY EVEN ALL:SUDDEN LOSS ALARM WATER WARNING 0,8 <br /> SITE 201383 `'TOP BIT 1 STOP ALL:HIGH PRODUCT ALARM HIGH WATER LIMIT: 2.0 <br /> DATA LENGTH: 7 DATA ALL:INVALID FUEL LEVEL <br /> SHIFT TIME 1 2:00 AM RS-232 SECURITY ALL:PROBE OUT PIA},i OR LABEL VOL: 11682 <br /> SHIFT TIME 2 DISABLED CCDE : DISABLED ALL:HIGH WATER WARNING Ol+'ERFILL LIMIT 90% <br /> SHIFT TIME 3 DISABLED ALL:MAX PRODUCT ALARM 10513 <br /> SHIFT TIME 4 DISABLED '^:)MM BOARD 2 (FXMOD) ALL:GROSS TEST FAIL HIGH PRODUCT 95°'d <br /> BAUD RATE 2400 HLL:PERIODIC TEST FAIL 11098 <br /> TANK PER TST NEEDED WRN PARITY ODD mLL:ANNUAL TEST FAIL DELIVERY LIMIT 14% <br /> DISABLED `TOP BIT 1 STOP ALL:GROSS FAIL LINE TNK 1752 <br /> TANK ANN TST NEEDED WRN DATA LENGTH: 7 DATA <br /> DISABLED RS-232 SECURITY LIQUID SENSOR ALMS LOW PRODUCT 670 <br /> ODE : DISABLED i-tLL:FUEL ALARM LEAI( ALARM LIMIT: 6 <br /> LINE RE-ENABLE METHOD DIAL TYPE TONE ALL:SENSOR OUT ALARM SUDDEN LOSS LIMIT: 99 <br /> PASS LINE TEST HNSW£R ON : 1 RING ALL:SHORT ALARM TANK TILT 0.00 <br /> MODEM SETUP STRING ALL:WATER ALARM PROBE OFFSET 0.00 <br /> LINE PER TST NEEDED WRN ALL:WATER OUT ALARM <br /> DISABLED DIAL TONE INTERVAL: '32 ALL:HIGH LIQUID ALARM <br /> LINE ANN TST NEEDED WRN ALL:LOW LIQUID ALARM SIF'HDN MANIFOLDED TANKS <br /> 2iMM BOARD 3 IRS-232) ALL:LIQUID WARNING Tit: NONE <br /> LINE ANN TST NEEDED WRN <br /> BAUD RATE 4800 LINE MANIFOLDED TANKS <br /> PARITY NONE <br /> DAYS = 355 PRESSURE LINE LEAK Tit: NONE <br /> L114E ANN TST NEEDED ALM STOP BIT 1 STOP ALL:GROSS LINE FAIL <br /> DAYS = 365 DATA LENGTH: 8 DATA ALL:ANNUAL LINE FAIL <br /> RS-232 SECURITY ALL:PER TST NEEDED WRN LEAK: MIN PERIODIC: 50% <br /> PRINT TC VOLUMES DUDE : DISABLED HLL:P£R TST NEEDED ALM 5841 <br /> DISABLED ALL:PLLD OPEN ALARM LEAK MIN ANNUAL 513% <br /> AUTO TRANSMIT SETTINGS: ALL:PLLD SHUTDOWN ALARI°1 <br /> TEMP' COMPENSATION 5841 <br /> VALUE (DEG F ): 60.0 ALL:PERIODIC LINE FAIL <br /> STICK HEIGHT OFFSET AUTO LEAK ALARM LIMIT ALL:ANN TST NEEDED WRN <br /> AL <br /> DISABLED PERIODTYPE <br /> TEST TY <br /> DISABLED L:ANN TST NEEDED ALM <br /> ULLAGE: 90:b AUTO HIGH WATER LIMIT pLL:LOW PRESSURE ALARM STANDARD <br /> DISABLED HLL:CONT HANDLE ALM <br /> AUTO OVERFILL LIMIT ALL:LN EQUIP FAULT ALM HI''lNUAL TEST FAIL <br /> H-PROTOCOL DATA FORMAT DISABLED <br /> HEIGHT AUTO LOW PRODUCT ALARM DISABLED <br /> PRECISION TEST DURATION DISABLED <br /> HOURS: 200 AUTO THEFT LIMIT F'BRIOD[C TEST FAIL <br /> 0.20 GPH LINE TEST P12'ABLED ALARM DISABLED <br /> AUTO-CONFIRM: ENABLED AUTO DELIVERY STARTF.'OSS TEST FAIL <br /> 0.10 GPH LINE TEST DISABLED ALARM DISABLED <br /> AUTO-CONFIRM: ENABLED AUTO DELIVERY END <br /> PRINT ESUL_ISION LINE DISABLED - Hrald TEST AVERAGING: OFF <br /> TEST RESULTS: DISABLED ;AUTO EXTERNAL INPUT ON PER TEST AVERAGING: OFF <br /> DAYLIGHT SAVING TIME DISABLED <br /> ENABLED <br /> START DATE AUTO EXTERNAL INPUT OFF TANK TEST NOTIFY: OFF <br /> BAR WEEK 2 SUN TRANSMIT <br /> START TIME AUTO SENSOR FUEL ALARM TNK TST SIPHON BREAKOFF <br /> 2:00 AM DISABLED <br /> END DATE AUTO SENSOR WATER ALARM DELIVERY DELAY I MIN <br /> NOV WEEK I SUN DISABLEDF'UMF' THRESHOLD 15.00% <br /> END TIME `'UTO SENOR OUT ALARM <br /> 2:00 AM DISABLED <br /> RE-DIRECT LOCAL PRINTOUT AUTO DELAY TIME : 5 SEC <br /> DISABLED <br /> EURO PROTOCOL PREFIX <br /> S <br /> RECEIVER SETUP: <br /> SYSTEM SECURITY D B:Maintenance EHD Received via CERS submittal: <br /> 000000 1-_77-509-1249 <br /> R!J1%R TYPE: FACSIMILE 1/28/2023 <br /> MAINTENANCE HISTORY FORT NO: 2 <br /> LISABLED RETRY NO: 8 <br /> RETRY DELAY: 3 <br /> CONFIRMATION REPORT: ON <br /> TANK CHART SECURITY <br /> DISABLED <br /> CUSTOM ALARMS <br /> DISABLED <br /> SERVICE NOTICE <br /> 111 SABLED <br /> AUTO DIAL TIME SETUP: <br /> ISO 3166 COUNTRY <br /> :ODE: <br /> I'1 8:11aintenance <br /> DIAL ON DATE <br /> MASS DENSITY JUN 30, 2020 <br /> DI5'ABLED DIAL TIME : 9:09 AM <br /> RECEIVER REPORTS: <br />
The URL can be used to link to this page
Your browser does not support the video tag.