My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 2:44:35 PM
Creation date
1/13/2023 9:39:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0518288
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3250 W GRANT LINE RD TRACY 95377
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
""NOWA <br /> A=The distance from the seat surface of the upper drop tube to the bottom of the underground <br /> storage tank. The seat surface will vary depending on the type of installation. See below. <br /> Underneath Fill Adapter Underneath Bucket Inside Bucket <br /> (EBW Legacy Series) (Phil-Tite Series) (Defender Series) <br /> 911111111111111111 <br /> El <br /> A <br /> 0 o a <br /> A <br /> A <br /> A <br /> NOTE: If you are installing into an OPW°spill container, measure from the bottom of the tank to <br /> the top face of the OPW®seal adaptor in the OPW®spill bucket. <br /> B = FINAL SHUTOFF VOLUME HEIGHT--According to industry recommended practices, FFS <br /> recommends that you set the final shutoff volume to a maximum of 95% of the actual tank <br /> capacity. To find the final shutoff volume height, multiply the actual tank capacity (gallons) by <br /> the final shutoff volume percentage. (If you are using 95%tank volume, multiply the actual tank <br /> capacity by .95.) You then locate the closest volume on the tank chart (provided by the tank <br /> manufacturer), and record the corresponding height for "B." <br /> ** NOTE: To accommodate tank tilt or increased/decreased usage of tank capacity, the final <br /> shutoff volume can be adjusted to a value other than 95%, providing it meets all applicable <br /> regulatory requirements, and is acceptable to the Authority Having Jurisdiction (AHJ). If the final <br /> shutoff volume is not installed at 95%, the installing contractor should document the new volume <br /> as intended and include it with the station records as reference for compliance inspections. The <br /> installing contractor can do this on the "OPV Installation Record Sheet" or any other applicable <br /> station records. <br /> If the final shutoff volume is installed greater than 95%, make sure in all cases that there is at <br /> least 250 gallons of ullage volume remaining so that "...none of the fittings located on the top of <br /> the tank are exposed to product due to overfilling" according to EPA 40 CFR Part 280. <br /> 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.