COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
255
>
2300 - Underground Storage Tank Program
>
PR0537549
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2023 11:49:02 AM
Creation date
1/17/2023 11:06:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0537549
PE
2351
FACILITY_ID
FA0021617
FACILITY_NAME
HARNEY LANE AM PM
STREET_NUMBER
255
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
062-580-40
CURRENT_STATUS
01
SITE_LOCATION
255 E Harney Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L12:FUEL ALARM s 3:VENT GAS VACUUM <br /> OUTPUT RELAY SETUP L13:FUEL ALARM �\ CATEGORY VAC SENSOR <br /> _ _ _ _ _ <br /> L14:FUEL ALARM P Uf"iP # <br /> L 3:SENSOR OUT ALARM Q ;:F'kEP'11 UNl <br /> R 1 :OVERFILL L 7:SENSOR OUT ALARM VOLUME: 25.0 GALLONS <br /> TYPE: L 8:SENSOR OUT ALARM RELIEF VALVE: : NO <br /> STANDARD L 9:SENSOR OUT ALARM <br /> NORMALLY OPEN L1O:SENSOR OUVALARM s 4:PREM VAPOR VACUUM <br /> LII :SENSOR OUT ALARM CATEGORY VAC SENSOR <br /> TANK: #: NONE L12:SENSOR OUT ALARM PUMP #: <br /> L13:SENSOR OUT ALARM Q ,`:PREMIUM <br /> L14:SENSOR OUT ALARM VOLUME: 111 .0 GALLONS <br /> IN-TANK ALARMS L 3:SHORT ALARM RELIEF VALVE: NO <br /> ALL:OVERFILL ALARM L 7:SHORT ALARM <br /> ALL:HIGH PRODUCT ALARM L 8:SHORT ALARM s 5:DIES PROD VACUUM <br /> L 9:SHORT ALARM CATEGORY VAC SENSOR <br /> LIO:SHORT ALARM PUMP #: <br /> LII :SHORT ALARM Q 3:DIESEL <br /> L12:SHORT ALARM VOLUME: 29.0 GALLONS <br /> L13:SHORT' ALARM RELIEF VALVE: : NO <br /> L14:SHORT ALARM <br /> ISD SITE ALARMS s 6:DIES VENT VACUUM <br /> CATEGORY VAC: SENSOR <br /> ISD GROSS PRES FAIL PUMP #: <br /> ISD DEGRD PRES FAIL Q 3:DIESEL <br /> ISD VAPOR LEAK FAIL VOLUME: 19.0 GALLONS <br /> PLLD LINE DISABLE SETUP RELIEF VALVE: : NO <br /> ISD HOSE ALARMS <br /> ALL:GROSS COLLECT FAIL s 8:ATf"I PRESURE <br /> ALL:DEGRD COLLECT FAIL CATEGORY ATM P SENSOR <br /> Q 1 :REGULAR ALL:FLOW COLLECT FAIL <br /> LIQUID SENSOR ALMS 5 9:PRES SNR 3-4 <br /> L 1 :FUEL ALARM Q 3:DIESEL CATEGORY VAPOR PRESSURE <br /> L 7:FUEL ALARM <br /> L B:FLIEL ALARMLIQUID SENSOR ALMS x10: 1-2 AFI"1 <br /> L 9:FUEL ALARM L 5:FUEL ALARM CATEGORY AIR FLOW METER <br /> L10:FUEL ALARM L 7:FUEL ALARM <br /> Lll :FUEL ALARM L e:FUEL ALARM 511 :3-4 AFM <br /> L 12:F UEL ALARM L 13:F UEL ALARM CATF-.'G('lRY AIR FLOW METER <br /> L13:FUEL ALARM L14:FUEL ALARM <br /> L14:FUEL ALARM L 5:SENSOR OUT ALARM s12:1;_6 AFM <br /> L 1 :SENSOR OUT ALARM L 7:SENSOR OUT ALARM CATEGORY AIR FLOW METER <br /> L 7:SENSOR OUT ALARM L '62ENSOR OUT ALARM <br /> L 9'SENSOR OUT ALARM 1_13:SENSOR OUT ALARM 513:7-8 AFM <br /> L1O:SENSOR OUT ALARM L14:SENSOR OUT ALARM CATEGORY AIR FLOW METER <br /> L11 :SENSOR OUT ALARM L 5:SHORT ALARM <br /> L12:SENSOR OUT ALARM L 7:SHORT ALARM 514:9-10 AFM <br /> L13:=:ENSOR OUT ALARM L 8:SHORT ALARM CATEGORY AIR FLOW METER <br /> L14:SENSOR OUT ALARM L13:SHORT ALARM <br /> L 1 :SHORT ALARM L14:SHORT ALARM sl5: 11-12 AFM <br /> L 7:SHORT ALARM CATEGORY AIR FLOW METER <br /> L 8:SHORT ALARM <br /> L 9:SHORT ALARM s16: 13-14 AFM <br /> LIO:SHORT ALHRM CATEGORY AIR FLOW METER <br /> L11 :SHORT ALARM <br /> L12:SHORT ALARM sl7: 15-16 AFM <br /> L13:SHORT ALARM CATEGORY AIR FLOW METER <br /> L14:SHORT ALARM <br /> 518:CANISTER <br /> ISD SITE ALARMS CATEGORY VAPQR VALVE <br /> ISD' GROSS PRES FAIL <br /> ISD DEGRD PRES FA I L S(°IARTSEfVSOR SETUP <br /> ISD VAPOR LEAK FAIL - - <br /> ISD HOSE ALARMS s 1 :REG PROD LINE VAC <br /> ALL:GROSS COLLECT FAIL CATEGORY VAC SENSOR <br /> ALL:DEGRD COLLECT FAIL PUMP #: <br /> ALL:FLOW COLLECT FAIL Q 1 :REGULAR <br /> VOLUME: 59.0 GALLONS <br /> Q 2:PREMIUNI RELIEF VALVE: : NO <br /> LIQUID SENSOR ALMS s 2:PREM PROD VACUUM <br /> L 3:FUEL ALARM CATEGORY VAC' SENSOR <br /> L 7:FUEL ALARM PUMP #: <br /> L 8:FUEL ALARM Q :PREM IUll <br /> L 9:FUEL ALARM VOLUME: 53.0 GALLONS <br /> L1O:FUEL ALARM RELIEF VALVE: : NO <br /> L 1 1 :F UEL ALARM <br />