Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> Hazardous Materials Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Pactiv Packaging Inc 1110 PERFORMANCE DR, STOCKTON January 18, 2023 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 5 HSC 25505(a)(1) Failed to electronically submit hazardous materials inventory for all reportable materials on site. <br /> OBSERVATION: The following chemicals are not reported to CERS: <br /> 1. 340 gallons of Ammonium Hydroxide Solution(GS13178 Grav WB pH Adjuster)by the Printing Press Machines <br /> and Outside in the Hazardous Materials Storage Area <br /> 2. 72 gallons of Propane cylinders located outside/west of the building. <br /> 3. 275 gallons Totes of Oily Water located North of the printing Press Machines <br /> The following chemicals observed Outside in the Hazardous Materials Storage Area and are not reported to CERS: <br /> 4. 275 gallons of Used Oil <br /> 5. 110 gallons of Oily Water <br /> 6. 3575 gallons of Grease Barrier <br /> 7. 2,200 INXKote Color Boost Primer <br /> The following chemicals located inside the Maintenance Shop and are not reported to CERS: <br /> 8. 1,380 cubic feet of Argon <br /> 9. 954 cubic feet of Argon/Caron Dioxide Mixture <br /> ---------------------------------------------------------------------------------------------------------------- <br /> The locations of the following reported chemicals are not complete within the submitted chemical forms: <br /> 1. Waste solid and Waste oil are stored in the hazardous waste storage area and the Cup Department. The <br /> chemical forms only addressed the hazardous waste storage area location <br /> 2. Mica is stored in the Press Department, inside the Ink storage Area, and Outside in the Hazardous Materials <br /> storage area.The chemical form for Mica does not address the Outside Hazardous Materials storage area location. <br /> 3. The Waste Sludge location in the chemical form is described as the Waste Storage Area. Per discussions with <br /> Al Yadao,the Waste Storage Area is the same as the Hazardous Waste Storage Area. Correct the location to <br /> Hazardous Waste Storage Area to accurately describe the location and be consistent with all other entries. <br /> 4. Printing Ink is stored outside in the Hazardous Materials Storage Area, Ink Room, and by the Press Printing <br /> Machines. The chemical form only addressed the outside Hazardous Materials Storage Area and Ink Room. <br /> REGULATION GUIDANCE:Any material that meets or exceeds the reportable quantity shall be reported in the <br /> facility's business plan. <br /> CORRECTIVE ACTIONS: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, add the materials to the hazardous material inventory, correct the chemical forms and <br /> submit to the EHD for approval. <br /> This is a repeat violation, Class ll. <br /> FA0010943 PR0520565 SCO01 01/18/2023 <br /> EHD 19-01 Rev.12/06/2021 Page 2 of 3 Hazardous Materials Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />