My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCUST
>
777
>
2800 - Aboveground Petroleum Storage Program
>
PR0546862
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2023 11:56:20 AM
Creation date
1/25/2023 9:01:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0546862
PE
2832
FACILITY_ID
FA0026544
FACILITY_NAME
EFUEL, LLC RIPON FACILITY
STREET_NUMBER
777
Direction
S
STREET_NAME
LOCUST
STREET_TYPE
AVE
City
RIPON
Zip
95366
APN
25935002
CURRENT_STATUS
01
SITE_LOCATION
777 S LOCUST AVE
P_LOCATION
05
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O Aq U I N Environmental Health Department <br /> lJ '\J I y <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> EFUEL, LLC RIPON FACILITY 777 S LOCUST AVE, RIPON January 19, 2023 <br /> SPCC Plan Requirements for Onshore Facilities(excluding production facilities) <br /> 719 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable containers n V n R ❑COS <br /> 720 CFR 112.8(d)(1) Failed to take corrective action on buried piping when exposed for any reason ❑V ❑R ❑COS <br /> 721 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping n V ❑R ❑COS <br /> 722 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service n V ❑R ❑COS <br /> 723 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 724 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ❑V ❑R ❑COS <br /> 725 CFR 112.8(d)(4) Failed to conduct integrity and leak testing on buried piping any time it is worked on ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ❑V ❑R ❑COS <br /> 727 CFR 112.7(a)(1), Plan failed to adequately describe overfill prevention methods for each container ❑V ❑R ❑COS <br /> 112.8(c)(8) <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation n V n R n COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation n V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25270.6(a)Failed to file HMBP or annual facility tank statement. <br /> OBSERVATION:A complete tank facility statement or a business plan has not been submitted by January 15th. <br /> The annual tank statement was submitted on January 19th,2023. <br /> REGULATION GUIDANCE: (a)(1)On or before January 1, annually,each owner or operator of a tank facility <br /> subject to this chapter shall file with the statewide information management system, a tank facility statement that <br /> shall identify the name and address of the tank facility, a contact person for the tank facility,the total storage <br /> capacity of the tank facility, and the location and contents of each petroleum storage tank that exceeds 10,000 <br /> gallons in storage capacity. A copy of a statement submitted previously pursuant to this section may be submitted <br /> in lieu of a new tank facility statement if no new or used storage tanks have been added to the facility or if no <br /> significant modifications have been made. For purposes of this section, a significant modification includes, but is <br /> not limited to, altering existing storage tanks or changing spill prevention or containment methods. <br /> (2)Notwithstanding paragraph (1), an owner or operator of a tank facility that submits a business plan, as defined in <br /> subdivision (d)of Section 25501 ,to the statewide information management system and that complies with Sections <br /> 25503 , 25505 ,25505.1 , 25507 ,25507.2 ,25508 , 25508.1 , and 25508.2 , satisfies the requirement in paragraph <br /> (1)to file a tank facility statement. <br /> CORRECTIVE ACTION: Immediately submit a complete and adequate tank facility statement or a business plan. <br /> Submit proof of correction to the EHD. <br /> This is a Class II violation. <br /> FA0026544 PR0546862 SCO01 01/19/2023 <br /> EHD 28-01 Rev.12/06/2021 Page 4 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.