Laserfiche WebLink
SAN JOAQUIN <br />C C_3 U IN I Y <br />Environmental Health Department <br />FA0004044 PR0232521 SCO01 01/19/2023 <br />EHD 23-01 Rev. 12/06/2021 Page 3 of 5 Underground Storage Tank Program CIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />TRACY USD- SERVICE CENTER <br />Facility Address: <br />1975 W LOWELL AVE, TRACY <br />Date: <br />January 19, 2023 <br />UST System Observations <br />311 <br />HSC 2636(a)(1), <br />25291(b) <br />Monitoring system incapable of detecting leak into secondary containment (pre -Jul 2003) <br />❑ V <br />❑ R <br />❑ COS <br />312 <br />HSC 25290.2(d) <br />Monitoring system incapable of detecting entry into secondary containment (Jul 2003 -Jun 2004) <br />❑ V <br />❑ R <br />❑ COS <br />313 <br />HSC 25290.1(d) <br />Monitoring system incapable of detecting entry into secondary containment (post -Jul 2004) <br />❑ V <br />❑ R <br />❑ COS <br />314 <br />CCR 2631(g), 2632(c) <br />(2) <br />Failure to continuously monitor interstitial space with audible -visual alarm system (pre -Jul 2004) <br />❑ V <br />❑ R <br />❑ COS <br />315 <br />HSC 25290.1(e) <br />Failure to maintain interstitial space to detect leaks before release to environment (post -Jul 2004) <br />❑ V <br />❑ R <br />❑ COS <br />316 <br />CCR 2636, 2643(c)(1), <br />2666(f) <br />Failure to install a line leak detector <br />❑ V <br />❑ R <br />❑ COS <br />317 <br />CCR 2636(f)(2) <br />Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow <br />❑ V <br />❑ R <br />❑ COS <br />318 <br />CCR 2635, 2637.1, <br />2665,2712 <br />Failed to meet spill container requirements <br />❑ V <br />❑ R <br />❑ COS <br />319 <br />CCR 2635, 2637.2, <br />2665,2712 <br />Failure to comply with overfill prevention equipment requirements <br />❑ V <br />❑ R <br />❑ COS <br />320 <br />CCR 2635(.)(1) <br />Overfill prevention was overridden <br />❑ V <br />❑ R <br />❑ COS <br />321 <br />HSC 25299(a)(9) <br />Leak detection equipment disabled or tampered with <br />❑ V <br />❑ R <br />❑ COS <br />322 <br />CCR 2717.1(g) <br />Removed, defaced, altered, or otherwise tampered with red tag <br />❑ V <br />❑ R <br />❑ COS <br />323 <br />CCR 2717.1(f); HSC <br />25292.3(c) <br />Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST <br />❑ V <br />❑ R <br />❑ COS <br />324 <br />HSC 25292.3(c)(1)(C) <br />Allowed dispensing from a UST that has a red tag affixed to the fill pipe <br />❑ V <br />❑ R <br />❑ COS <br />325 <br />CCR 2635, 2636(b), <br />2662,2712 <br />Failure to comply with the cathodic protection system requirements <br />❑ V <br />❑ R <br />❑ COS <br />326 <br />CCR 2631(b&d), <br />2666(b&e) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />❑ V <br />❑ R <br />❑ COS <br />327 <br />CCR 2638(a), 26410) <br />Leak detection equipment not installed/calibrated/operated/maintained per manufacturer instructions <br />❑ V <br />❑ R <br />❑ COS <br />328 <br />CCR 2630, 2632, 2643, <br />2644.1 <br />Equipment or methods used to monitor the UST system are not certified by an independent third -party <br />❑ V <br />❑ R <br />❑ COS <br />329 <br />CCR 2631.1, 2660(m) <br />UST system not compatible with the substance stored <br />❑ V <br />❑ R <br />❑ COS <br />330 <br />CCR 2636(f), 2666(c), <br />2666(f) <br />Failure of emergency generator line leak detector to restrict or shut off flow or trigger an alarm <br />❑ V <br />❑ R <br />❑ COS <br />331 <br />1 HSC 25281.6(a) <br />Failure of unburied below -grade emergency generator system to meet exemption conditions <br />❑ V <br />❑ R <br />❑ COS <br />332 <br />HSC 25283.5(a) <br />Failure of unburied below -grade UST system to meet exemption conditions <br />❑ V <br />❑ R <br />❑ COS <br />333 <br />CCR 2666(b)(2) <br />Failure to upgrade single -walled pipe to double -walled interstitially monitored pipe when repaired <br />❑ V <br />❑ R <br />❑ COS <br />334 <br />CCR 2670(b)(e)(f), <br />2671 <br />Failure to comply with temporary closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />335 <br />HSC 25298(c); CCR <br />2670,2672 <br />Failure to comply with all permanent closure requirements <br />❑ V <br />❑ R <br />❑ COS <br />336 <br />CCR 2638(f), 26410) <br />Failure to affix a tag/sticker on each monitoring equipment certified, repaired, or replaced <br />❑ V <br />❑ R <br />❑ COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3), <br />2641(b) <br />Safe suction piping failed to meet slope, check valve location, or inspection requirements <br />❑ V <br />❑ R <br />❑ COS <br />402 <br />CCR 2643(d) <br />Failure to conduct monitoring and maintain records for single -walled conventional suction (pre -1984) <br />❑ V <br />❑ R <br />❑ COS <br />403 <br />CCR 2643(d), 2661(f) <br />Failure to conduct 0.1 gph integrity test for single -walled conventional suction systems (pre -1984) <br />❑ V <br />❑ R <br />❑ COS <br />FA0004044 PR0232521 SCO01 01/19/2023 <br />EHD 23-01 Rev. 12/06/2021 Page 3 of 5 Underground Storage Tank Program CIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />