Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> facility Name: Facility Address: Date: <br /> Sutter Valley Hospitals dba Sutter Tracy 1420 N Tracy Blvd, Tracy November 13, 2023 <br /> File Rgview <br /> 121 HSC 25299(a)(8), False statements,representation,or certification made on an application,record,or other document V -R ❑COS <br /> 25299(b)(7) <br /> 122 CCR 2712(f) Failure to implement corrections and submit written response within 30 days of receiving the report ■V ■R ❑COS <br /> On Site Records <br /> 201 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance e V o R c COS <br /> 202 CCR 2712(i) Failure to retain a paper or electronic copy of the permit to operate at the facility n V e R e COS <br /> 203 CCR 2712(b)(1-2) Failure to maintain monitorfng records for 36 months and maintenance records for 60 months e V n R ❑COS <br /> 204 CCR 2712(b)(6) Failure to maintain records of repairs,lining,and upgrades on site,for the life of the UST u V o R c COS <br /> 205 CCR 2712(i) Failure to submit and have current UST Monitoring Plan readily accessible at the facility ❑V e R u COS <br /> 206 CCR 2712(i),2634(e) Failure to submit and have a current UST Response Plan readily available on site c V e R e COS <br /> 207 CCR 2716(0 Failure to maintain designated operator inspection reports and all attachments on site for 36 months _V :_R ❑COS <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements ■V ■R ❑COS <br /> 209 CCR 2715(.)(3), Failure to maintain a copy of the"Facility Employee Training Certificate"on-site ❑V ❑R ❑COS <br /> 2715(.)(4) <br /> 210 CCR 2715(.) Failure to provide initial training,train every 12 months,and have a trained employee present ❑V ❑R ❑COS <br /> 211 CCR 2715(.)(2) Failure to have or implement a training program approved by the UPA,at an unstaffed facility ❑V ❑R ❑COS <br /> 212 CCR 2651.MSC 25294 Failure to record any unauthorized release from primary containment V ❑R ❑COS <br /> 213 CCR 2650(e),2652 Failure to notify and submit report of reportable unauthorized release or record release L V �i R c COS <br /> 214 CCR 2712 Failure to comply with UST operating permit conditions o V u R ❑COS <br /> 215 CCR 2715 Designated operator,service tech,or installer did not possess current certifications iiV ❑R ❑COS <br /> 216 HSC 25281.5(b)(2) Failure to meet exclusion requirements for unburied fuel piping at a marina -V ❑R ❑COS <br /> 217 HSC 25281.5(b)(3) Failure to meet exemption requirements for emergency generator unburied fuel piping V R ❑COS <br /> UST System Observations <br /> 301 HSC 25292.1(a) Failure to operate UST system to prevent unauthorized releases including leaks,spills and overfills n V ❑R r.COS <br /> 302 CCR 2630(d),2641(a) Leak detection equipment not installedlmaintainedilocated to detect leaks at earliest opportunity ❑V i i R =COS <br /> 303 CCR 2630(d),2641(a) Failure to maintain piping to allow liquid to flow into sump(i.e.failure to remove test hoots) ❑V n R -COS <br /> 304 CCR 2631(a),HSC Failure to construct,operate,and maintain primary containment as product-tight c V _R r COS <br /> 25290-1(c) <br /> 305 HSC 25290.1,25290.2, Failed to maintain secondary containment(e.g.failure of secondary containment testing) n V ❑R i,COS <br /> 25291 <br /> 306 HSC 25291(e) Failure to remove,analyze,and properly dispose of water is secondary containment(pre-Jul 2003) V R COS <br /> 307 HSC 25290.1(.3), Failure to keep water out of the secondary containment system(post-Jul 2003) ❑V R COS <br /> 25290.2(.3) <br /> 308 CCR 2632(.),2634(d), Failure of the leak detection equipment to have an audible and visual alarm _.;V ❑R COS <br /> 2636(f) <br /> 309 CCR 2666(b)(2), Failure to have continuous monitoring that activates audible-visual alarm or stops flow at dispenser V R n COS <br /> 2636(f)(1) <br /> 310 CCR 26360(4) Failure to meet monitoring requirements in lieu of being tightness tested every 12 months V -,R ❑COS <br /> FAD002562 PR0231736 SC001 11113!2023 <br /> EH023-01 Rev,1210612021 Page 2 of 5 Underground Storage Tank Program MR <br /> 1868 E. Hazelten Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />