My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2023 1:39:39 PM
Creation date
2/8/2023 1:40:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
AT&T CALIFORNIA - UE058
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Monitoring System Certification Form <br />7. LINE LEAK DETECTOR TESTING <br />SI Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) <br />Simulated release <br />3 GPH <br />rate verified: (Check all that apply.) <br />0.2 GPH Yes No NA IN 0.1 GPH El <br />Has the testing apparatus been properly calibrated? • • M <br />For emergency generator tank systems, does the LLD create an audible and visual <br />alarm when a leak is detected? • <br />For mechanical LLDs, does the LLD restrict the flow through the pipe when a <br />release is detected? o El • <br />For electronic LLDs, does the turbine automatically shut off when a release is <br />detected? El El • <br />For electronic LLDs, does the turbine automatically shut off if any portion of the <br />monitoring system is disabled or disconnected? El El • <br />For electronic LLDs, does the turbine automatically shut off if any portion of the <br />monitoring system malfunctions or fails a tightness test? El NI <br />For electronic LLDs, have all accessible wiring connections been visually inspected <br />for kinks and breaks? El • <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />Were all LLDs confirmed operational within regulatory requirements? <br />LLD ID LLD Model Lines Monitored Pass Fail <br />DO <br />• • <br />El • <br />Describe all answers marked "No" or "Fail" and proposed remedy in Section 9. <br />List all monitoring equipment either replaced or repaired in Section 9 <br />Page 4 of 6
The URL can be used to link to this page
Your browser does not support the video tag.