My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0042352
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CABE
>
24184
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0042352
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/25/2024 12:08:54 PM
Creation date
2/16/2023 11:08:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0042352
PE
4366
STREET_NUMBER
24184
Direction
S
STREET_NAME
CABE
STREET_TYPE
RD
City
TRACY
Zip
95304-
APN
25015028
ENTERED_DATE
7/28/2021 12:00:00 AM
SITE_LOCATION
24184 S CABE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
January 28, 2022 Lab ID : STK2230878 <br /> San Joaquin Co. Environmental Health Dep Customer : 3-17919 <br /> Quality Control-Inorganic <br /> Constituent Method Date/ID Type Units Cone. QC Data DQO Note <br /> Wet Chem <br /> Nitrate 300.0 (VI 2240198-002) MSD mg/L 40.00 101% 85-119 <br /> MSRPD m 10.00 4.2% 519 <br /> 300.0 01/19/22:200991njb CCB mg/1 0.00 0.5 <br /> CCV mg/1 20.00 102% 90-110 <br /> CCB mg/I 0.00 0.5 <br /> CCV m 20.00 102% 1 90-110 <br /> Nitrate+Nitrite as N 300.0 01/19/22:200703NJB Blank In ND <0.1 <br /> Nitrate Nitrogen 300.0 01/19/22:200703NJB Blank m ND <0.1 <br /> itrite 300.0 01/19/22:200703NJB Blank mg/L ND <0.5 <br /> LCS mg/L 15.00 97.1% 90-110 <br /> Ms mg/L 30.00 94.9% 74-126 <br /> (VI 2240198-001) MSD mg/L 30.00 101% 74-126 <br /> MSRPD mg/L 10.00 5.7% :520 <br /> Ms mg/L 30.00 96.1% 74-126 <br /> (VI 2240198-002) MSD mg/L 30.00 102% 74-126 <br /> MSRPD m 10.00 5.8% 1 :520 <br /> 300.0 01/19/22:200991njb CCB mg/I 0.0520 0.5 <br /> CCV mg/I 15.00 102% 90-110 <br /> CCB mg/I 0.0520 0.5 <br /> CCV m 15.00 101% 90-110 <br /> Nitrite Nitrogen 300.0 01/19/22:200703NJB Blank m ND <0.2 <br /> Sulfate 300.0 01/19/22:200703NJB Blank mg/L ND <0.5 <br /> LCS mg/L 50.00 105% 90-110 <br /> MS mg/L 100.0 100% 82-124 <br /> (VI 2240198-001) MSD mg/L 100.0 106% 82-124 <br /> MSRPD mg/L 10.00 4.9% :523 <br /> MS mg/L 100.0 92.9% 82-124 <br /> (VI 2240198-002) MSD mg/L 100.0 98.5% 82-124 <br /> MSRPD m 10.00 3.0% <23 <br /> 300.0 01/19/22:200991njb CCB mg/I 0.146 0.5 <br /> CCV _ mg/I 50.00 110% 90-110 <br /> CCB mg/1 0.151 0.5 <br /> CCV mg/I 50.00 110% 90-110 <br /> BAS 5540C 01/19/22:201365jba CCB mg/I -0.0611 0.25 <br /> CCV mg/1 1.000 94.5% 90-110 <br /> CCB mg/1 -0.0611 0.25 <br /> CCV m 1.000 94.5% 90-110 <br /> BAS Extraction 5540C 01/19/22:201030jba Blank mg/L ND <0.1 <br /> LCS mg/L 0.5000 94.1% 86-114 <br /> BS mg/L 0.5000 99.8% 86-114 <br /> BSD mg/L 0.5000 95.4% 86-114 <br /> BSRPD m 0.5000 4.4% <5 <br /> Definition <br /> ICB :Initial Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> BS :Blank Spikes-A blank is spiked with a known amount of analyte.It is prepared to verify that the preparation process is not <br /> affecting analyte recovery. <br /> Page 8 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.