My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2023 2:49:20 PM
Creation date
2/22/2023 11:03:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Duncan Compliance: Dba, R&D Compliance Testing_______________ <br />Secondary Containment/SB989 (707) 621-0378 <br />Line/Leak Detectors <br />Tank Monitor Certification <br />California UST Service Technician #5246802-UT <br />California UST Designated Operator #5246802-UT <br />CSLB C61/D40 License #1036490 <br /> <br /> <br /> <br />Secondary Containment Test Procedure Used To Determine Test Results <br /> <br /> <br />Tank Secondary Containment The Service Technician will test and certify using <br />methods developed and recommended by the Tank Manufacture, Industry Standard or <br />Professional Engineer. Test procedure recommended and used is a vacuum slowly <br />applied to establish a stable vacuum of 6 inches Hg. for one hour using a <br />Standard Industry Vacuum Gauge with a range of -- <br />mercury. The test is completed at the end of one hour/Tanks with a Volume of 20,000 <br />Gallons or less, and 2 hours for Tanks that exceed a Volume of 20,000 Gallons, if the <br />vacuum reading does not decrease below the established vacuum or the Threshold <br />Criteria recommended by the Tank Manufacture, Industry Standard, or Professional <br />Engineer. <br /> <br />Product Piping Containment/Vent Piping Containment/Vapor Recovery Piping <br />Containment The Service Technician will test and certify using methods developed <br />and recommended by the Piping Manufacture, Bravo System UDC Manufacture, Industry <br />Standard or Professional Engineer. Test procedure recommended and used is, Nitrogen <br />Gas pressure, slowly applied to establish a stable pressure of 5 psi for one hour or 3 Psi <br />for 1 hour using a Standard Industry Pressure Gauge with a range of 0 to 15 measured in <br />Bravo System Manufacture, Model B2000, constructed of Coated Steel, with an O Ring <br />Seal at Primary/Secondary Product Piping Interface at end of Product Piping Run at <br />Bravo System Manufacture recommends a pressure range of 2 Psi to 3 Psi <br />maximum applied test pressure. The test is completed at the end of one hour if the <br />pressure reading does not decrease below the established pressure or the Threshold <br />Criteria recommended by the Piping Manufacture, Bravo System UDC Manufacture, <br />Industry Standard or Professional Engineer. <br /> <br />Turbine/Product Piping Sump/Fill Riser Sump/Remote Fill Sump/Transition/Vent <br />Sump/Spill Container/Misc. Sump connected to UST System The Service <br />Technician will test and certify using methods developed and recommended by the Sump <br />Manufacture, Industry Standard or Professional Engineer. The test procedure <br />recommended and used is Hydrostatic with a level change indicator that has been <br />developed to indicate a standard leak rate of ¼ inch in 24 hours within 30 minutes, and <br />has been examined and reviewed by a third party Professional Engineer. The Service <br />Technician will perform all Hydrostatic Testing using the Caldwell Systems Level
The URL can be used to link to this page
Your browser does not support the video tag.