2019 CALIFORNIA GREEN BUILDING STANDARDS CODE <br /> NONRESIDENTIAL MANDATORY MEASURES, SHEET 1 (JANUARY 2020, INCLUDES AUGUST 2019 SUPPLEMENT) <br /> INSPECTOR INSPECTOR INSPECTOR INSPECTOR <br /> SIGNOFF SIGNOFF SIGNOFF SIGNOFF <br /> 5.504.4 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with Sections 5.504.4.1 TABLE5.504.4.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL Exception: Refrigeration systems containing low-global warming potential (low-GWP)refrigerant with a GWP <br /> through 5.504.4.6. TABLE 5.504.4.5 - FORMALDEHYDE LIMITS1 value less than 150 are not subject to this section. Low-GWP refrigerants are nonozone-depleting refrigerants that <br /> COATINGS2,3 include ammonia, carbon dioxide(CO2), and potentially other refrigerants. <br /> 5.504.4.1 Adhesives, sealants and caulks.Adhesives, sealants, and caulks used on the project shall meet MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION <br /> GRAMS OF VOC PER LITER OF COATING,LESS WATER&LESS EXEMPT COMPOUNDS <br /> the requirements of the following standards: 5.508.2.1 Refrigerant piping. Piping compliant with the California Mechanical Code shall be installed to be <br /> PRODUCT CURRENT LIMIT <br /> COATING CATEGORY CURRENT VOC LIMIT accessible for leak protection and repairs. Piping runs using threaded pipe, copper tubing with an outside <br /> 1. Adhesives, adhesive bonding primers adhesive primers, sealants, sealant primers and caulks shall comply HARDWOOD PLYWOOD VENEER CORE 0.05 diameter(OD) less than 1/4 inch, flared tubing connections and short radius elbows shall not be used in <br /> with local or regional air pollution control or air quality management district rules where applicable, or FLAT COATINGS 50 refrigerant systems except as noted below. <br /> SCAQMD Rule 1168 VOC limits, as shown in Tables 5.504.4.1 and 5.504.4.2. Such products also shall HARDWOOD PLYWOOD COMPOSITE CORE 0.05 <br /> comply with the Rule 1168 prohibition on the use of certain toxic compounds chloroform, ethylene dichloride, NONFLAT COATINGS 100 5.508.2.1.1 Threaded pipe. Threaded connections are permitted at the compressor rack. <br /> methylene chloride, perch loroethylene and trichloroethylene), except or aerosol products as specified in PARTICLE BOARD 0.09 p p p p <br /> subsection 2, below. NONFLAT HIGH GLOSS COATINGS 150 5.508.2.1.2 Copper pipe. Copper tubing with an OD less than 1/4 inch may be used in systems with a refrigerant <br /> 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulkingcompounds in units of MEDIUM DENSITY FIBERBOARD 0.11 charge of 5 pounds or less. <br /> p ( SPECIALTY COATINGS g <br /> product, less packaging,which do not weigh more than one pound and do not consist of more than 16 fluid THIN MEDIUM DENSITY FIBERBOARD2 0.13 <br /> ounces)shall comply with statewide VOC standards and other requirements, including prohibitions on use of ALUMINUM ROOF COATINGS 400 5.508.2.1.2.1 Anchorage. One-fouth-inch OD tubing shall be securely clamped to a rigid base to keep vibration <br /> certain toxic compounds, of California Code of Regulations, Title 17, commencing with Section 94507. 1.VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, levels below 8 mils. <br /> BASEMENT SPECIALTY COATINGS 400 AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR <br /> ADDITIONAL INFORMATION,SEE CALIFORNIA CODE OF REGULATIONS,TITLE 17,SECTIONS 93120 THROUGH 5.508.2.1.3 Flared tubing connections. Double-flared tubing connections may be used for pressure controls, <br /> BITUMINOUS ROOF COATINGS 50 93120.12. valve pilot lines and oil. <br /> TABLE 5.504.4.1 - ADHESIVE VOC LIMIT1,2 BITUMINOUS ROOF PRIMERS 350 2.THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16 INCHES(8 MM). <br /> Exception: Single-flared tubing connections may be used with a multiring seal coated with industrial sealant V,10 A a e <br /> Less Water and Less Exempt Compounds in Grams per Liter BOND BREAKERS 350 suitable for use with refrigerants and tightened in accordance with manufacturer's recommendations. �� �I <br /> 5.504.4.6 Resilient flooring systems. For 80 percent of floor area receiving resilient flooring, installed resilient cw F S H/1 <br /> ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT CONCRETE CURING COMPOUNDS 350 flooring shall meet at least one of the following: 5.508.2.1.4 Elbows. Short radius elbows are only permitted where space limitations prohibit use of long radius P <br /> > <br /> INDOOR CARPET ADHESIVES 50 CONCRETE/MASONRY SEALERS 100elbows. NO.C-33467 <br /> 1. Certified under the Resilient Floor Covering Institute (REGI) FloorScore program; <br /> CARPET PAD ADHESIVES 50 DRIVEWAY SEALERS 50 2. Compliant with the VOC-emission limits and testing requirements specified in the California Department of 5.508.2.2 Valves. Valves Valves and fittings shall comply with the California Mechanical Code and as follows. REN:0/31/2023 e <br /> Public Health's 2010 Standard Method for the Testing and Evaluation Chambers, Version 1.1, February 2010; v <br /> OUTDOOR CARPET ADHESIVES 150 DRY FOG COATINGS 150 3. Compliant with the Collaborative for High Performance Schools California (CA-CHPS)Criteria Interpretation 5.508.2.2.1 Pressure relief valves. For vessels containing high-GWP refrigerant, a rupture disc shall be installed -0 <br /> WOOD FLOORING ADHESIVES 100 for EQ 7. and EQ 7.1 (formerly EQ 2.2)dated July 2012 and listed in the CHPS High Performance Product between the outlet of the vessel and the inlet of the pressure relief valve. <br /> FAUX FINISHING COATINGS 350 DataBase; or <br /> RUBBER FLOOR ADHESIVES 60 FIRE RESISTIVE COATINGS 350 4. Products certified under UL GREENGUARD Gold (formerly the Greenguard Children's&Schools Program). 5.508.2.2.1.1 Pressure detection.A pressure gauge, pressure transducer or other device shall be installed in the <br /> SUBFLOOR ADHESIVES 50 FLOOR COATINGS 100 5.504.4.6.1 Verification of compliance. Documentation shall be provided verifying that resilient flooring materials space between the rupture disc and the relief valve inlet to indicate a disc rupture or discharge of the relief valve. <br /> CERAMIC TILE ADHESIVES 65 FORM-RELEASE COMPOUNDS 250 meet the pollutant emission limits. 5.508.2.2.2 Access valves. Only Schrader access valves with a brass or steel body are permitted for use. Q ❑ <br /> VCT&ASPHALT TILE ADHESIVES 50 5.504.5.3 Filters. In mechanically ventilated buildings, provide regularly occupied areas of the building with air 5.508.2.2.2.1 Valve caps. For systems with a refrigerant charge of 5 pounds or more, valve caps shall be brass or Ln <br /> GRAPHIC ARTS COATINGS (SIGN PAINTS) 500 filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value (MERV)of 8. steel and not plastic. N <br /> DRYWALL& PANEL ADHESIVES 50 HIGH-TEMPERATURE COATINGS 420 MERV 8 filters shall be installed prior to occupancy, and recommendations for maintenance with filters of the same <br /> value shall be included in the operation and maintenance manual. 5.508.2.2.2.2 Seal caps. If designed for it, the cap shall have a neoprene O-ring in place. W Q) <br /> COVE BASE ADHESIVES 50 INDUSTRIAL MAINTENANCE COATINGS 250 <br /> MULTIPURPOSE CONSTRUCTION ADHESIVES 70 LOW SOLIDS COATINGS1 120 Exceptions: 5.508.2.2.2.2.1 Chain tethers. Chain tethers to fit ovr the stem are required for valves designed to have seal caps. J Q <br /> J <br /> STRUCTURAL GLAZING ADHESIVES 100 1.An ASHRAE 10%to 15% efficiency filter shall be permitted for an HVAC unit meeting the 2013 California Exception:Valves with seal caps that are not removed from the valve during stem operation. <br /> MAGNESITE CEMENT COATINGS 450 Energy Code having 60,000 Btu/h or less capacity per fan coil, if the energy use of the air delivery system is Q Z <br /> SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 0.4 W/cfm or less at design air flow. 5.508.2.3 Refrigerated service cases. Refrigerated service cases holding food products containing vinegar and , <br /> MASTIC TEXTURE COATINGS 100 g 9 9 P 9 9 <br /> 2. Existing mechanical equipment. salt shall have evaporator coils of corrosion-reistant material, such as stainless steel; or be coated to prevent <br /> OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 METALLIC PIGMENTED COATINGS 500 corrosion from these substances. ❑ <br /> 5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS)CONTROL. Where outdoor areas are provided for <br /> SPECIALTY APPLICATIONS MULTICOLOR COATINGS 250 smoking, prohibit smoking within 25 feet of building entries, outdoor air intakes and operable windows and within 5.508.2.3.1 Coil coating. Consideration shall be given to the heat transfer efficiency of coil coating to maximize LN LL <br /> PVC WELDING 510 the building as already prohibited by other laws or regulations; or as enforced by ordinances, regulations or energy efficiency. <br /> PRETREATMENT WASH PRIMERS 420 policies of any city, county, city and county, California Community College, campus of the California State a] J <br /> CPVC WELDING 490 University, or campus of the University of California,whichever are more stringent. When ordinances, regulations 5.508.2.4 Refrigerant receivers. Refrigerant receivers with capacities greater than 200 pounds shall be fitted with Q <br /> PRIMERS, SEALERS, & UNDERCOATERS 100 or policies are not in lace, post signage to inform building occupants of the prohibitions. g g p g <br /> p p pg p p a device that indicates the level of refrigerant in the receiver. <br /> ABS WELDING 325 REACTIVE PENETRATING SEALERS 350 U <br /> SECTION 5.505 INDOOR MOISTURE CONTROL 5.508.2.5 Pressure testing. The system shall be pressure tested during installation prior to evacuation and <br /> PLASTIC CEMENT WELDING 250 RECYCLED COATINGS 250 5.505.1 INDOOR MOISTURE CONTROL. Buildings shall meet or exceed the provisions of California Building charging. y p g <br /> ADHESIVE PRIMER FOR PLASTIC 550 ROOF COATINGS 50 Code, CCR, Title 24, Part 2, Sections 1203 (Ventilation)and Chapter 14 (Exterior Walls). For additional measures Q <br /> not applicable to low-rise residential occupancies, see Section 5.407.2 of this code. 5.508.2.5.1 Minimum pressure. The system shall be charged with regulated dry nitrogen and appropriate tracer IL <br /> CONTACT ADHESIVE 80 RUST PREVENTATIVE COATINGS 250 gas to bring system pressure up to 300 psig minimum. <br /> SPECIAL PURPOSE CONTACT ADHESIVE 250 SECTION 5.506 INDOOR AIR QUALITY <br /> SHELLACS: 5.506.1 OUTSIDE AIR DELIVERY. For mechanically or naturally ventilated spaces in buildings, meet the 5.508.2.5.2 Leaks. Check the system for leaks, repair any leaks, and retest for pressure using the same gauge. <br /> STRUCTURAL WOOD MEMBER ADHESIVE 140 minimum requirements of Section 120.1 (Requirements For Ventilation)of the California Energy Code, or the <br /> CLEAR 730 applicable local code, whichever is more stringent, and Division 1, Chapter 4 of CCR, Title 8. 5.508.2.5.3 Allowable pressure change. The system shall stand, unaltered,for 24 hours with no more than a +/- <br /> TOP&TRIM ADHESIVE 250 OPAQUE 550 one pound pressure change from 300 psig, measured with the same gauge. <br /> 5.506.2 CARBON DIOXIDE (CO2) MONITORING. For buildings or additions equipped with demand control � <br /> SUBSTRATE SPECIFIC APPLICATIONS ventilation, CO2 sensors and ventilation controls shall be specified and installed in accordance with the 5.508.2.6 Evacuation. The system shall be evacuated after pressure testing and prior to charging. <br /> METAL TO METAL 30 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 requirements of the California Energy Code, Section 120(c)(4). <br /> STAINS 250 SECTION 5507 ENVIRONMENTAL COMFORT 5.508.2.6.1 First vacuum. Pull a system vacuum down to at least 1000 microns (+/-50 microns), and hold for 30 <br /> . <br /> PLASTIC FOAMS 50 minutes. <br /> STONE CONSOLIDANTS 450 5.507.4 ACOUSTICAL CONTROL. Employ building assemblies and components with Sound Transmission Class <br /> POROUS MATERIAL(EXCEPT WOOD) 50 (STC)values determined in accordance with ASTM E 90 and ASTM E 413, or Outdoor-Indoor Sound 5.508.2.6.2 Second vacuum. Pull a second system vacuum to a minimum of 500 microns and hold for 30 <br /> SWIMMING POOL COATINGS 340 Transmission Class (OITC)determined in accordance with ASTM E 1332, using either the prescriptive or minutes. <br /> WOOD 30 <br /> performance method in Section 5.507.4.1 or 5.507.4.2. <br /> FIBERGLASS 80 TRAFFIC MARKING COATINGS 100 5.508.2.6.3 Third vacuum. Pull a third vacuum down to a minimum of 300 microns, and hold for 24 hours with a <br /> Exception: Buildings with few or no occupants or where occupants are not likely to be affected by exterior noise, maximum drift of 100 microns over a 24-hour period. <br /> TUB&TILE REFINISH COATINGS 420 as determined by the enforcement authority, such as factories, stadiums, storage, enclosed parking <br /> WATERPROOFING MEMBRANES 250 structures and utility buildings. CHAPTER 7 <br /> 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, Exception: [DSA-SS] For public schools and community colleges,the requirements of this section and all INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS <br /> THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. WOOD COATINGS 275 <br /> subsections apply only to new construction. 702 QUALIFICATIONS <br /> 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE WOOD PRESERVATIVES 350 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of <br /> 5.507.4.1 Exterior noise transmission, prescriptive method.Wall and roof-ceiling assemblies exposed to the U <br /> THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR ZINC-RICH PRIMERS 340 HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification w <br /> noise source making up the building or addition envelope or altered envelope shall meet a composite STC rating <br /> QUALITY MANAGEMENT DISTRICT RULE 1168, program. Uncertified persons may perform HVAC installations when under the direct supervision and <br /> of at least 50 or a composite OITC rating of no less than 40,with exterior windows of a minimum STC of 40 or 0 <br /> www.arb.ca.gov/DRDB/SC/CURHTML/Rl 168.PDF 1.GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER&EXEMPT COMPOUNDS responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC <br /> g <br /> 2.THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN OITC of 30 in the following locations: systems. Examples of acceptable HVAC training and certification programs include but are not limited to the THE TABLE. 1. Within the 65 CNEL noise contour of an airport. following: <br /> 3.VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, 1. State certified apprenticeship programs. <br /> ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE,FEB. 1,2008.MORE INFORMATION IS AVAILABLE Exceptions: 2. Public utility training programs. <br /> TABLE 5.504.4.2 - SEALANT VOC LIMIT FROM THE AIR RESOURCES BOARD. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. <br /> a. Ldn or CNEL for military airports shall be determined by the facility Air Installation Compatible Land Use Zone 4. Programs sponsored by manufacturing organizations. <br /> Less Water and Less Exempt Compounds in Grams per Liter (AICUZ)plan. Z <br /> 5.504.4.3.2 Verification. Verification of compliance with this section shall be provided at the request of the b. Ldn or CNEL for other airports and heliports for which a land use plan has not been developed shall be 5. Other programs acceptable to the enforcing agency. 0 <br /> SEALANTS CURRENT VOC LIMIT enforcing agency. Documentation may include, but is not limited to, the following: determined by the local general plan noise element. a <br /> 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible <br /> ARCHITECTURAL 250entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties E2 <br /> 1. Manufacturer's product specification 2. Within the 65 CNEL or Ldn noise contour of a freeway or expressway, railroad, industrial source or 0 <br /> 2. Field verification of on-site product containers necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the U) <br /> MARINE DECK 760 P fixed-guideway source as determined by the Noise Element of the General Plan. satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to LU <br /> other certifications or qualifications acceptable to the enforcing agency, the following certifications or education ' <br /> NONMEMBRANE ROOF 300 5.504.4.4 Carpet Systems.All carpet installed in the building interior shall meet at least one of the testing and 5.507.4.1.1. Noise exposure where noise contours are not readily available. Buildings exposed to a noise q p 9 g <br /> product requirements: may be considered by the enforcing agency when evaluating the qualifications of a special inspector: <br /> ROADWAY 250 level of 65 dB Leq - 1-hr during any hour of operation shall have building, addition or alteration exterior wall and <br /> roof-ceiling assemblies exposed to the noise source meeting a composite STC rating of at least 45(or OITC 35), 1. Certification b a national or regional green building program or standard publisher. w <br /> 1. Carpet and Rug Institute's Green Label Plus Program. with exterior windows of a minimum STC of 40 or OITC 30 y g g g p g p I- <br /> SINGLE-PLY ROOF MEMBRANE 450 ( ) 2. Certification b a statewide energy consulting or verification organization, such as HERS raters, building 2. Compliant with the VOC-emission limits and testing requirements specified in the California Department of Y gY g g g Q <br /> Public Health Standard Method for the Testingand Evaluation of Volatile Organic Chemical Emissions from performance contractors, and home energy auditors. D <br /> OTHER 420 Indoor Sources and Environmental Chambers, Version 1.1, February 2010 also known as CDPH Standard 5.507.4.2 Performance Method. For buildings located as defined in Section 5.507.4.1 or 5.507.4.1.1,wall and 3. Successful completion of a third party apprentice training program in the appropriate trade. <br /> Using ry ( roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered 4. Other programs acceptable to the enforcing agency. <br /> SEALANT PRIMERS Method V1.1 or Specification 01350). envelope shall be constructed to provide an interior noise environment attributable to exterior sources that does <br /> 3. NSF/ANSI 140 at the Gold level or higher; not exceed an hour) equivalent noise level (Leq-1 Hr of 50 dBA in occupied areas duringan hour of operation. Y <br /> ARCHITECTURAL 4. Scientific Certifications Systems Sustainable Choice; or Y q ( q ) p y p Notes: W <br /> 5. Compliant with the Collaborative for High Performance Schools California (CA-CHPS)Criteria Interpretation <br /> NONPOROUS 250 5.507.4.2.1 Site Features. Exterior features such as sound walls or earth berms may be utilized as appropriate to 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they <br /> for EQ 7.0 and EQ 7.1 (formerly EQ 2.2)dated July 2012 and listed in the CHPS High Performance Product the building, addition or alteration project to mitigate sound migration to the interior. <br /> POROUS 775 Database. are inspecting for compliance with this code. <br /> 5.507.4.2.2 Documentation of Compliance. An acoustical analysis documentingcomplyinginterior sound levels 2. HERS raters are special inspectors certified by the California Energy Commission (CEC)to rate homes in <br /> MODIFIED BITUMINOUS 500 5.504.4.4.1 Carpet cushion.All carpet cushion installed in the building interior shall meet the requirements of the p y California according to the Home Energy Rating System (HERS). ISSUE: 25 APRIL 2022 <br /> p p g q shall be prepared by personnel approved by the architect or engineer of record. <br /> Carpet and Rug Institute Green Label program. <br /> MARINE DECK 760 5.507.4.3 Interior sound transmission. Wall and floor-ceiling assemblies separating tenant spaces and tenant [BSC-CG]When required by the enforcing agency, the owner or the responsible entity acting as the owner's PROJECT NO: <br /> agent shall employ one or mores special inspectors to provide inspection or other duties necessary to substantiate <br /> OTHER 750 5.504.4.4.2 Carpet adhesive.All carpet adhesive shall meet the requirements of Table 5.504.4.1. spaces and public places shall have an STC of at least 40. g p y p p p p ry FILE: <br /> compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing <br /> NOTE: FOR ADDITIONAL INFORMATION REGARDING METHODS TO 5.504.4.5 Composite wood products. Hardwood plywood, particleboard and medium density fiberboard Note: Examples of assemblies and their various STC ratings may be found at the California Office of Noise agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a DRAWN BY: W.N.R. <br /> MEASURE THE VOC CONTENT SPECIFIED IN THESE TABLES, SEE SOUTH composite wood products used on the interior or exterior of the buildings shall meet the requirements for Control: www.toolbase.org/PDF/CaseStudies/stc_icc_ratings.pdf. certification from a recognized state, national or international association, as determined by the local agency. The <br /> COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.). area of certification shall be closely related to the primary job function, as determined by the local agency. CHECKED BY: <br /> Those materials not exempted under the ATCM must meet the specified emission limits, as shown in Table SECTION 5.508 OUTDOOR AIR QUALITY <br /> 5.504.4.5. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they <br /> 5.504.4.3 Paints and coatings.Architectural paints and coatings shall comply with VOC limits in Table 1 of the 5.508.1 Ozone depletion and greenhouse gas reductions. Installations of HVAC, refrigeration and fire are inspecting for compliance with this code. <br /> ARB Architectural Coatings Suggested Control Measure, as shown in Table 5.504.4.3, unless more suppression equipment shall comply with Sections 5.508.1.1 and 5.508.1.2. <br /> 9 99 5.504.4.5.3 Documentation. Verification of compliance with this section shall be provided as requested by the <br /> stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty enforcing . Documentation shall include at least one of the following: 703 VERIFICATIONS <br /> a <br /> coatings categories listed in Table 5.504.4.3 shall be determined by classifying the coating as a Flat, Nonflat or agency. <br /> 5.508.1.1 Chlorofluorocarbons (CFCs). Install HVAC, refrigeration and fire suppression equipment that do not contain CFCs. 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited <br /> Nonflat-High Gloss coating, based on its gloss, as defined in Subsections 4.21, 4.36 and 4.37 of the 2007 1. Product certifications and specifications. to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other <br /> California Air Resources Board Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High 2. Chain of custodycertifications. methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific <br /> Gloss VOC limit in Table 5.504.4.3 shall apply. 5.508.1.2 Halons. Install HVAC, refrigeration and fire suppression equipment that do not contain Halons. documentation or special inspection is necessary to verify compliance, that method of compliance will be specified <br /> CALIFORNIA <br /> pp Y• 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, P P rY Y P p p <br /> Section 93120, et seq.). 5.508.2 Supermarket refrigerant leak reduction. New commercial refrigeration systems shall comply with the in the appropriate section or identified applicable checklist. GBC <br /> 5.504.4.3.1 Aerosol Paints and coatings.Aerosol paints and coatings shall meet the PWMIR Limits for ROC in 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, provisions of this section when installed in retail food stores 8,000 square feet or more conditioned area, and that COMPLIANCE <br /> Section 94522(a)(3)and other requirements, including prohibitions on use of certain toxic compounds and ozone the Australian AS/NZS 2269 or European 636 3S standards. utilize either refrigerated display cases, or walk-in coolers or freezers connected to remote compressor units or <br /> depleting substances, in Sections 94522(c)(2)and (d)(2)of California Code of Regulations, Title 17, commencing 5. Other methods acceptable to the enforcing a CHECKLIST <br /> p g enc g Y• condensing units. The leak reduction measures apply to refrigeration systems containing high-global-warming <br /> with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District potential (high-GWP) refrigerants with a GWP of 150 or greater. New refrigeration systems include both new <br /> additionally comply with the percent VOC by weight of product limits of Regulation 8 Rule 49. facilities and the replacement of existing refrigeration systems in existing facilities. <br /> DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE 2016 CALIFORNIA GREEN BUILDING STANDARDS(CALGREEN)CODE.DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT,INCLUDING VERIFICATION WITH THE FULL CODE. G012 <br />