Laserfiche WebLink
SHEET NOTES : <br /> O1 ALL DIMMING BALLAST/DRIVER SHALL COMPLY <br /> WITH T24, MINIMUM REQUIRED CONTROL STEPS <br /> AND UNIFORM ILLUMINANCE LEVEL. LED <br /> DRIVERS) TO MATCH OPERATION OF DIMMING <br /> CONTROL SWITCH FOR PROPER LIGHTING <br /> CONTROLS. PROVIDE 12 GA. VERTICAL <br /> STRUT SUPPORT PER U.B.C. <br /> O LIGHTING FIXTURES ARE TO BE APPROVED BY STANDARD #47-18, AT <br /> THE ARCHITECT. ELECTRICAL CONTRACTOR TO <br /> COORDINATE WITH ARCHITECT THE ACTUAL $11 0 0 0 12'-0" O.C. EACH WAY. <br /> LOCATION AND MOUNTING HEIGHT OF LIGHTING <br /> FIXTURES PRIOR INSTALLATION. DEG. <br /> 90 EG. <br /> O3 COORDINATE ALL LIGHTING CONTROLS WITH o G 0 <br /> AUDACY DIMMING PANEL CONTRACTOR/ Q <br /> EQUIPMENT VENDOR. Q < 1/2" $" 12'-0"O.C., MAX. 1/2" <br /> ACOUSTICAL TILE <br /> GENERAL NOTES : � � CEILING (MAX. 4 PSF.) <br /> NOTE . 4 -° MAX. NOTE : <br /> 1. ELECTRICAL CONTRACTOR SHALL VERIFY (E) FIELD CONDITIONS PRIOR TO O <br /> BID. ANY DISCREPANCIES BETWEEN DRAWINGS & (E) CONDITIONS FOUND o S O o ALL LIGHT FIXTURES SHALL BE ATTACHED TO <br /> TIE2 <br /> DURING INSTALLATION SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION cV ( ) ADJACENT WALLT <br /> & SHOULD BE RESOLVED AT NO ADDITIONAL COST TO THE OWNER. CEILING MAIN & CROSS RUNNERS, THE CEILING GRID TO RESUST A HORIZONAL <br /> KEEP MAIN & CROSS RUNNERS FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. �5�° AR�� <br /> 2. ALL WIRING TO BE COPPER "THWN," UNLESS OTHERWISE NOTED. SEE w F. sH, <br /> PANEL SCHEDULE FOR SIZING. 3/8" MIN. CLEAR OF OTHER WALLS FLUSH OR RECESSED LIGHT FIXTURES AND AIR <br /> 0o TERMINALS OR SERVICES WEIGHTING MORE THAN <br /> 3. ELECTRICAL CONTRACTOR TO SUPPLY OWNER WITH DRAWINGS OF THE HANGERS WIRES MUST BE FASTENED NO.C-33467 <br /> AS-BUILT CONDITION OF THE WIRING SYSTEM UPON COMPLETION. 56 POUNDS MAY BE SUPORTED ON HEAVY-DUTY RENO/31/2023 <br /> WITH NOT LESS THAN (3) TIGHT <br /> 4. ALL CONSTRUCTION OF THIS PROJECT SHALL CONFORM TO ALL LOCAL GRID, BUT MUST HAVE 2412 GA. SLACK SAFETY WIRESo 0 o TURNSSPLAY WIRES MUST HAVE 9 `4°�� <br /> CODES, ORDINANCES AND CURRENT ELECTRIC & BUILDING CODES. . FLUSH OR RECESSED LIGHT FIXTURES AND AIR <br /> (4) TIGHT TURNS FOR #12 GA. WIRES. TERMINALS OR SERVICES WEIGHTING MORE THAN <br /> 5. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ALL LOCAL COUNTY, - <br /> STATE AND FEDERAL CODES, ORDINANCES, RULES AND REGULATIONS 4 12 GA. MIN HANGER WIRES N <br /> INCLUDING ALL REQUIREMENTS OF GOVERNING AGENCIES. ELECTRICAL ( ) GA.(MIN) 2X4' "T"-BAR SUSPENDED CEILING 56 POUNDS AND ALL FIXTURES AND AIR TERMINALS <br /> CONTRACTOR SHALL PAY ALL COSTS, ASSOCIATED WITH THE INSTALLATION, AT EACH SEISMIC BRACE. SYSTEM BY DONN CORP. OR OR SERVICES IN INTERMEDIATE DUTY GRID MUST Ld <br /> INCLUDING BUILDING APPLICATION FEES, ETC. APPROVED EQUAL. - I.C.B.O.#2244 BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN > 13 <br /> 6. ALL LIGHTING CIRCUITS SHALL BE RESPONSIBILITY OF THE ELECTRICAL (4) TIMES THE LOAD. Q N <br /> CONTRACTOR. IF ANY DISCREPANCIES WITH SWITCHING LAYOUT, VERIFY WITH TYPICAL CEILING PLAN TCEILING SECTION N <br /> ARCHITECT. LIGHTING SHALL MEET TITLE 24 REQUIREMENTS. U 0) <br /> 7. VERIFY THE TYPE OF CEILING SYSTEM WITH GENERAL CONTRACTOR OR LL <br /> CEILING CONTRACTOR. PROVIDE FIXTURES WHICH ARE COMPATIBLE WITH <br /> THE CEILING SYSTEM AND INCLUDE ALL REQUIRED MOUNTING ACCESSORIES <br /> AND HARDWARE. U Z <br /> 8. SUPPORT CEILING MOUNTED LIGHTING FIXTURES DIRECTLY FROM THE <br /> BUILDING STRUCTURE. DO NOT SUPPORT FIXTURES FROM PIPING, <br /> DUCTWORK OR ANY OTHER EQUIPMENT, OR SOLELY FROM THE SUSPENDED LL <br /> CEILING. _ <br /> 9. ALL LIGHTING FIXTURES SHALL BE NRTL LISTED. J <br /> Q <br /> 10. ALL <br /> SWITCH <br /> LOCATIONS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TOROUGH- O U <br /> N. <br /> 11. CONTRACTOR SHALL PROVIDE ADDITIONAL EXIT SIGN(S) IF REQUIRED BY (2) #8 SCREWS, WOOD or METAL z <br /> THE CITY FIRE MARSHALL INSPECTOR AT NO ADDITIONAL COST TO THE <br /> OWNER. PROVIDE SPLAY WIRES @ 12'-0" O.C. <br /> 8" IST, PURLIN, or SUB-PURLIN. <br /> MAX.. � <br /> 12. ALL EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF IN BOTH DIRECTIONS AND IN PLANES <br /> EGRESS TRAVEL. PARALLEL TO RUNNERS. <br /> U <br /> 13. ANY FIXTURE SUBSTITUTION MUST BE APPROVED BY THE ARCHITECT OR 1/2" DIAM. RIDGID CONDUIT E.M.C. <br /> OWNER PRIOR TO BID. MAIN RUNNER ( ) \ ❑ <br /> 14. DRAWING SHOWS CIRCUITING AND SWITCHING REQUIREMENTS AND FIXTURE HANGER WIRE - ADD ONE PAIR % COMPRESSION STRUT. <br /> TYPES ONLY. VERIFY EXACT LIGHTING FIXTURES AND STANDARD SWITCHING OF BRACING WIRES PARALLA TO \45 DEG. LO <br /> WITH ARCHITECT AND OWNER PRIOR TO INSTALLATION. ALSO VERIFY WALL AT 8'-0" O.C. SPLICE AS NEEDED W/ 3/4" DIAM. X <br /> EXACT LIGHTING FIXTURES FINISH PRIOR TO INSTALLATION. CROSS RUNNER �_7 6" LONG CONDUIT and #8 MACHINE <br /> 15. PROVIDE 90 MINUTE MINIMUM EMERGENCY BATTERY PACK FOR EXIT SIGNS. SCREWS and NUTS. <br /> (SHALL COME TO FULL BRIGHT). NO. 12 GAGE SPLAY WIRE (4) IN ISI <br /> MAIN RUNNER <br /> 16. ALL QUANTITIES SHALL BE FIELD VERIFIED PRIOR TO BID. NOTIFY ENGINEER PLANE OF RUNNER VERTICAL ANGLE <br /> FOR ANY DISCREPANCIES IN DRAWINGS. OF 45 DEG. ALL WIRES SECURED CROSS-CUT BOTTOM OF CONDUIT <br /> 2" FROM � <br /> 17. FOR ELECTRICAL PENETRATIONS OF FIRE-RATED FLOOR/CEILING, PROVIDE TO RUNNERS APPROX. (1" DEEP) and FIT SNUG TO "T"-BAR <br /> PROTECTION PER 2019 CBC CHAPTER 7 RECESSED FIXTURES SHALL BE INTERSECTIONS. AT INTERSECTIONS. <br /> LISTED AND SHALL BE EITHER ONE OF THE FOLLOWING: <br /> Lu <br /> A. FIXTURES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCE-RATED NOTE: <br /> ASSEMBLIES OR ACOUSTIC CEILING TILE <br /> B. FIXTURES SHALL BE PROTECTED WITH A LISTED FIRE-RATED LIGHT <br /> ADDITIONAL WIRE AT EACH CORNER NOTE: o <br /> COVER. OF LIGHTS DIAGONAL WIRE EVERY PROVIDE COMPRESSION STRUTS at <br /> 18. INSTALL GROUNDED (NEUTRAL) CONDUCTORS OR PROVIDE RACEWAY TO 144 SQ. FT. WITHIN 2" OF CROSS 12'-0" O.C. IN EACH DIRECTION for <br /> ALL SWITCH LOCATIONS AS PER 2019 C.E.C. ARTICLE 404.2. CONTINUOUS ANGLE WITH RUNNER CONNECTED TO STRUCTURE 144 SQ. FT. and WITHIN 6'-0" of <br /> 19. ALL CONTROLS AND SWITCHES INTENDED TO BE USED BY OCCUPANT OF SELF-TAPPING SCREW AT ABOVE AT THE HORIZON IN (4) THE WALL. STRUT TO BE FASTENED <br /> THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, DIRECTIONS, 90 DEG. APART WITH i AT CONVERGENCE of THE SPLAYED z <br /> APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL EACH WALL STUD. o <br /> LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE THE FIRST POINT WITHIN 4 FROM WIRES PER U.B.C. (e,7)-2. <br /> BOTTOMONO ORHDEVICE <br /> UNCTBOX <br /> ION ORNOR <br /> DEV CE BOX ABOVE INCHES <br /> THE FINISHED EDTO FLOOR. E I .C.B.O. #E 82244 <br /> WALL ,C,B,Q, #E 82244 THE WALL <br /> r� U <br /> U) <br /> 20. LIGHTING FIXTURES INSTALLED IN A SUSPENDED CEILING SHALL BE FASTEN I .C.B.O. #ER2244 0 , <br /> TO THE CEILING FRAMING MEMBER AT ALL FOUR CORNERS WITH SCREWS <br /> AND ATTACHED 12 AWG CEILING WIRES TO THE LIGHT FIXTURE AT <br /> DIAGONALLY OPPOSITE CORNERS AND TO THE STRUCTURAL CEILING. <br /> w <br /> 21. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 Q <br /> FOOT-CANDLE (11 LUX) AT THE WALKING SURFACE LEVEL, IN THE EVENT <br /> OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL <br /> AUTOMATICALLY ILLUMINATE THE FOLLOWING AREAS: <br /> A. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES <br /> THAT REQUIRE TWO OR MORE MEANS OF EGRESS. <br /> B. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS <br /> REQUIRED TO HAVE TWO OR MORE EXITS. <br /> C. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EXITS <br /> DISCHARGE UNTIL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS ISSUE: 15 APRIL 2022 <br /> REQUIRED TO HAVE TWO OR MORE EXITS. <br /> D. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION PROJECT NO: <br /> 1024.1, IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. <br /> E. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1008.1.5., FOR EXIT FILE: <br /> DISCHARGE DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR <br /> DRAWN BY: W.N.R. <br /> MORE EXITS. <br /> CHECKED BY: <br /> 22. ELECTRICAL PLANS ARE INTENDED TO SHOW, IN A GENERAL WAY, THE <br /> APPROXIMATE LOCATION AND LOADS OF THE INTENDED FIXTURE AND <br /> EQUIPMENT. EXACT LOCATIONS AND MATERIALS SHALL BE DETERMINED IN <br /> THE FIELD BY THE INSTALLING CONTRACTOR AND SHALL CONFORM TO THE <br /> PROVISIONS AS SET FORTH IN THE 2019 EDITIONS OF THE CALIFORNIA <br /> ELECTRICAL CODE, CALIFORNIA ENERGY CODE AND CALIFORNIA GREEN <br /> BUILDING CODE. <br /> 23. PROVIDE A SEPARATE NEUTRAL CONDUCTOR FOR EACH AND EVERY PHASE CEILING / LIGHTING <br /> (LINE) CONDUCTOR; TO COMPLY WITH 2019 CEC ARTICLE 210.4 FOR DETAILS <br /> MULTI-WIRE CIRCUITS AND TO PERMIT INDIVIDUAL OPERATION/CONTROL OF AND <br /> EACH BRANCH CIRCUIT OR PROVIDE TIE HANDLE ON BREAKERS TO SUIT SCHEDULE <br /> SINGLE NEUTRAL ON MULTI-CIRCUITS HOMERUNS- NEUTRAL MUST BE <br /> MINIMUM 10 AWG ON MULTI CIRCUITS. <br /> 24. THE CONTRACTOR/INSTALLER SHALL IMMEDIATELY NOTIFY IN WRITING THE <br /> PROJECT OWNER AND M+R (CONSULTANT) FOR CLARIFICATION OF ANY <br /> DISCREPANCY IN THIS DESIGN PACKAGE OR ANY CONFLICT WITH OTHER <br /> TRADES PRIOR TO COMMENCING THE WORK. ALL WORKS, SERVICES, <br /> INSTALLATION OR SUPPLY OF EQUIPMENT AND DEVICES RESULTING FROM <br /> ALTERATION OR DEVIATION FROM THIS DESIGN AND ITS INTENT WITHOUT A-5 . 1 <br /> THE WRITTEN NOTIFICATION TO AND APPROVAL FROM M+R SHALL BE ON <br /> THE ACCOUNT OF THE CONTRACTOR/INSTALLER. <br />