Engineering PHYSICAL DATA <br /> Plan Views RLN - RMN Merchandiser Drip Pipe(in.) 11/4 <br /> Merchandiser Liquid Line(in.) 3/s <br /> Plan View Merchandiser Suction Line(in.) 5/8 <br /> Narrow Reach-In <br /> 2,3,4& 5 Door Dimensions shown as in.&(mm). <br /> A <br /> 4/N.(102 mm)REQUIRED AIR GAP <br /> 28 <br /> I Skids <br /> External <br /> I - 1 6 IeI (711) <br /> 37 6/8 48 ts2 Bottom 3 <br /> (0 s/87 Base <br /> (856) 9Front o55/a778)121 ) PPrt ( 43) 3 <br /> 9— Rfi—O— <br /> gtle- <br /> - 3/4 <br /> —— <br /> Electrical Wrieway _—— _ (Splashguard__`—__—_ _ (1010) <br /> 4 - (See note') Water Seal 4 661/4 <br /> ttozll ( (See Note") Front Relay&Terminal 10�1 <br /> �I 113/4 Block Location 13/4j yL (1683) <br /> I (44) 26th 5-Door shown (44) <br /> I <br /> I <br /> (673) <br /> (12 foot shown above) _ <br /> I Dr 2 Dr 3 Dr 4 Dr 5 Dr <br /> General _ _ <br /> (A) Case Length(without ends or partitions) 31 1/2(800) 62(1575)) 92 012(2350) 122 r/e(3121) 153 r/e(3896) <br /> **NOTE:Each solid end adds approximately 2 3/s in(60 mm)to length of line up;each partition add approximately 2 3/4 in(70 mm); <br /> Icase to case joints can add approximately 1/a in(3 nun)for gasket material. <br /> Maximum O/S dimension of case back to front 39 3/4(1010) 39 3/4(1010) 39 3/4(1010) 39 3/4(1010) 39 3/4(1010) <br /> (Includes btanper.Add 26112 in.(673 mm)for door swing.) <br /> Back of case to rear of splashguard 353/4(908) 351/4(908) 353/4(908) 35 3/4(908) 353/.(908) <br /> Width ofSkidrail 41/2(114) 41/2(114) 41/2(114) 41/2(114) 41/2(114) <br /> Width of Bottom Front Support 6(152) 6(152) 6(152) 6(152) 6(152) <br /> Stub-up area between front support and splashguard 6 3/a(162) 63/8(162) 63/s(162) 63/8(162) 6 3/8(162) <br /> Electrical Service IN <br /> RH end of case to the center of nearest knockout 4(102) 4(102) 4(102) 4(102) 4(102) <br /> RH end of case to the center of LH knockout 271/2(698) 58(1473) 88 1/2(2248) 118 7/s(3019) 149 3/9(3794) <br /> Back O/S of case to center of knockout 375/s(956) 37 5/e(956) 375/s(956) 375/8(956) 375/&(956) <br /> *NOTE:Electrical Field Wiring Connection Point is at terminal. <br /> Waste Outlet Q <br /> (B) Right end of case to center of waste outlet 153/4(400) 233/4(603) 54 1/4(1378) 46 1/4(1175) 76 5/s(1946) <br /> Back O/S of case to center of waste outlet 305/&(778) 30 5/a(778) 305/a(778) 30 5/a(778) 305/s(778) <br /> Water Seal I <br /> Edge of water seal to center of waste outlet 13(330) 13(330) 13(330) 13(330) 13(330) <br /> Schedule 40 PVC drip pipe 1 1/4(32) 1 1/4(32) 1 1/4(32) 1 1/4(32) 1 1/4(32) <br /> *"NOTE:Field installed water seal outlets,tees,and connectors are shipped with case <br /> Refrigeration Outlet l._._% <br /> RH end of case to center of RH refrigeration outlet 5 3/a(137) 5 1/8(137) 5 3/a(137) 5 3/8(137) 5 3/8(137) <br /> Back O/S of case to center of refrigeration outlet 32(813) 32(813) 32(813) 32(813) 32(813) <br /> Outside bottom front supports from end of case 63/4(170) 63/4(170) 6 3/4(1 70) 6 3/4(170) 6 3/4(170) <br /> Center bottom front support from Centerline NA 24(610) 24(610) 24(610) 24(610) <br /> Distance between Center and Outside supports will vary <br /> 2 of 7 U.S.&CANADA 1-800-922-1919•MEXICO 1-800-890-2900 RLN with Innovator Doors or Innovator III Doors <br /> Technical Data Sheet <br /> Equip #2, 3 -Page 2 <br />