WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1616
>
1600 - Food Program
>
PR0162643
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2024 4:14:36 PM
Creation date
3/2/2023 3:43:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0162643
PE
1619 - RETAIL MKT >1000 SQ FT (=/>2 DEPTS)
FACILITY_ID
FA0001709
FACILITY_NAME
COCOS FOOD - STOCKTON
STREET_NUMBER
1616
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\ymoreno
Supplemental fields
Site Address
1616 E MARCH LN STOCKTON 95210
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 <br /> 1 {E) <br /> 3- 1 /2"X15" CLAM BM © 8'-0" (N) EXHAUST FAN —GREENHECK CUBE <br /> SIZE-240, 1 HP OR EQUAL <br /> OC, TYP BELOW — PRODUCT <br /> —FIELD VERIFY <br /> FY <br /> ABOVE EQUIPMENT ROOM —SET MIN. <br /> 5,200 CFM —SEE DWG 4/-- <br /> .............................. <br /> ARCHITECTURE.ENGINEERING <br /> 4072 Hensley Circle <br /> ! I I I <br /> EI Dorado Hills,CA 95762 <br /> phone.916.501.}964 <br /> 00 0 wcheong4inemodc.com <br /> 3 r 1(N) Woo Cheong, AIA <br /> /1 15 L <br /> P {E) 6 X 6 STL 5-7/ "X 2 4" 3 These drawings are instruments of service and are the property of Wco <br /> G M G I R D E _ Cheong,AIA All designs and other information on the drawings are for <br /> I WNSER #3 <br /> ESTL TY the use on the specified project and shall not be used otherwise without <br /> I POST S I LO W —S E E I STR U CT I l A 1 — the expressed written permission of Woo Cheong,AIA. <br /> L0y y I IWritten dimensions on these drawings shall have recedence oP ver scaled <br /> dimensions. Contractors sha11 verify and be responsible for all dimension <br /> and conditions on the job site,and this office shall be notified of any <br /> variations from the dimensions and conditions as shown on these <br /> drawings. <br /> NowConsuftant AI�CyCONDEN ER #1N CQ DENSER # a3,900 L S N C NDENSER 3c-3osz <br /> III2, 30 LBS 1 520 LBS <br /> F OF Cp,41F0 <br /> 1 f I I ! ! I I I I ConsultantV <br /> C10 t <br /> 2X6 JOIST @ 16" OC, ` now. <br /> �t <br /> TYP —SEE STRUCT <br /> NOTE: REFRIGERATION EXHAUST FAN SIZE CALCULATIONS: TOTAL <br /> 2,700 LBS REFRIGERANTS 100 X2,700 = 5, 196 CFM <br /> 2 ENLARGED ROOF PLAN <br /> Refrigeration <br /> Equipment <br /> Display Cases <br /> Installation <br /> at <br /> Cocos Food <br /> EQUIPMENT SCHEDULE <br /> ID DESCRIPTION MANUFACTURER MODELQTY DETAILS PROVIDED BY <br /> OWNER G.C. NOTES <br /> 01 FROZEN FOOD DOORS WITH <br /> ELECTRIC DEFROST HUSSMANN RLN 12 DOORS SEE REFRIGERATION DRAWINGS X <br /> 02 FROZEN FOOD DOORS WITH <br /> ELECTRIC DEFROST HUSSMANN RLNi 34 SEE REFRIGERATION DRAWINGS X <br /> DOORS 10+10+8+6 DOORS <br /> .� VERALL ROOF PLAN 03 FROZEN FOOD DOORS WITH HUSSMANN RLNf 30 DOORS <br /> ELECTRIC DEFROST SEE REFRIGERATION DRAWINGS X <br /> 10+10+10 DOORS <br /> 04 FROZEN FOOD DOORS WITH <br /> GAS DEFROST HUSSMANN RLN 6 SEE REFRIGERATION DRAWINGS <br /> DOORS X 3+3 DOORS <br /> 05 FROZEN FOOD DOORS WITH <br /> GAS DEFROST HUSSMANN RLN 23 SEE REFRIGERATION DRAWINGS <br /> DOORS X 5+4+5+4+5 DOORS <br /> 06 DAIRY DISPLAY CASE HILLPHONEX 05DM 56' SEE REFRIGERATION DRAWINGS X <br /> 12'+12'+12'+12F+$1 <br /> 07 MUTI-DECK CASE HILLPHONEX 05DM 40' SEE REFRIGERATION DRAWINGS X <br /> 12'+12'++8'+8' <br /> 08 MUTI-DECK CASE HILLPHONEX 05DM 56' SEE REFRIGERATION DRAWINGS X <br /> 12'+12'+12'+12481 <br /> 09 MUTI-DECK CASE HILLPHONEX 05DM 156' SEE REFRIGERATION DRAWINGS X <br /> 12' X13 EA <br /> 10 SINGLE-WIDE ISLAND CASE HUSSMANN FN <br /> 4 SEE REFRIGERATION DRAWINGS X <br /> NOTES: 11 DOULBE-WIDE ISLAND CASE <br /> WITH GLASS REVEAL HUSSMANN FW 2 SEE REFRIGERATION DRAWINGS X 8'+END CASE=11' <br /> . CONDENSER SUPPORT FRAMES SPACES ® 5'—O" OC. MAX W1 0,875" FROZEN FO <br /> MOUNTING HOLE @ EACH END OF EACH FRAME. PROVIDE 4X6 12 OD DOORS WITH HUSSMANN FW <br /> BLOCKING BELOW WITH ANCHORAGE PER DETAIL, TYP. ELECTRIC DEFROST 1 SEE REFRIGERATION DRAWINGS X <br /> END+8'+END=14' 1616 E March Ln <br /> . TOP OF MECHANICAL UNITS 5'-0" MAX ABOVE ROOF DECK, TYP. 13 FROZEN FOOD DOORS WITH <br /> ELECTRIC DEFROST HUSSMANN FW 1 SEE REFRIGERATION DRAWINGS X END+8 +8+END=22 Stockton, CA 95210 <br /> N) MECH. UNIT � 14 FROZEN FOOD DOORS WITH <br /> 14 GA TOP PLATE ELECTRIC DEFROST HUSSMANN FW 1 SEE REFRIGERATION DRAWINGS X <br /> ANCHOR TO CURB WITH ATTACHMENT TO END-�8'+s'+EN = ' <br /> D 22 SHEET TITLE <br /> SUPPORT PER }, II <br /> MANUFACTURER CURB. #12 SMS 0 SOC MAINTAIN MINIMUM ID -m 15 FROZEN FOOD DOORS WITH H <br /> ELECTRIC DEFROST HUSSMANN FW <br /> $ 1 SEE REFRIGERATION DRAWINGS X <br /> . FUER SIDE) UP-BLAST TYFDE FAN. FAN CLEARANCE FROM ALL END+8'+8'+END=22' <br /> ( "s� BOLTS EACH (4 MINDISCHARGE SHALL BE A OUTSIDE AIR INTAKES- FRO FOOD DOORS WITH HUSSMANN 16 ZEN ROOF PLAN /DETAIL <br /> CORNER MIN.} MINIMUM OF 4>a" FROM THEELECTRIC DEFROST HU1 S <br /> #12 WOODS SCREWS 0 8"OC ROOF, PROVIDE CURB FW EE REFRIGERATION DRAWINGS X 8'+END CASE= <br /> (4 MIN. PER SIDE) HEIGHT ACCORDINGLY. SWITCH <br /> 3R DISCONNECT � EQUIP SCHEDULE <br /> SWITGH 17 PRODUCE ISLAND CASE HUSSMANN (1) PWw + (2) <br /> ON SEALANT BED HINGED SUB-B,45E WITH PWWEE 3 SEE REFRIGERATION DRAWINGS X 12' + 2 EN <br /> STL TUBE FRAME BY MFR ( } D CASES <br /> @ PERIMETER OF EACH MIN 4X CONT. SHAPED LOCK $ HASP 18 PRODUCE ISLAND CASE HUSSMANN (1) PWW-12 + (2) <br /> 2X CONDENSER UNIT SLEEPER WITH z"0 THRU VENTILATED CURB pWWEE 3 SEE REFRIGERATION DRAWINGS X <br /> _ 12' + (2) END CASES REVISIONS DATE <br /> E) ROOFING MEMBRAfNE BOLTS AT 48"OC MAX r`� <br /> SEGURE ROOF CURB TO 19 PRODUCE !BLAND CASE HUSSMANN (1) PWW-8 + (2) <br /> �2 MIN PER SIDE) INSULATED ROOF CURB pEE 3 SEE REFRIGERATION DRAWING 1 <br /> BLOCKING BELOW ROOF S X 8' + (2) END CASES <br /> WHERE MECH CURB ON SEALANT BED FLASH e COUNTER FLASH WITH '/4"0 LAG SCREcUs. zo SEAFOOD SERVICE <br /> CASE HILLPHONEX BSD-SW 8R+6R 14' SEE REFRIGE Q <br /> ALIGNS WITH ROOF MINIMUM (2) PER SIDE. RATIO <br /> ROOF SHEATHING N DRAWINGS X 8'+6' <br /> MEMBER (BEAM OR lE) ROOFING MEMBRAINE 3 <br /> PURLIN) BELOW, (N)4X6 BLOCKING OR DBL 21 MEAT SERVICE CASE HILLPHONEX SMD-8RG 24' SEE REFRIGERATION DRAWINGS X 12'+12' �4 <br /> MIT BLOCKING AND RAFTER WITH HU HANGER 4x6 BLOCKING BETtUEEN <br /> USE 4"0 LAG BOLTS EACH END TO (E) PURLINS, ROOF FRAMING MEMBERS, 22 SEAFOOD SERVICE CASE HUSSMANN <br /> SECURE TO FRAMING WITH DSFM-I2-REM 36' SEE REFRIGERATION DRAWINGS X <br /> WITH 4�" MIN EMBED TYP., UNO 1z'+12'+12' ----- <br /> �2) 51MP6ON PU46, J015T <br /> INTO ROOF MEMBER HANGERS. (1) EACH END. 23 MUTI-DECK CASE <br /> ROOF FRAMING MEMBER HILLPHONEX 05DM 32' SEE REFRIGERATION DRAWINGS <br /> BEYOND X 12'+12'+12'+s' <br /> 24 MUTT-DECK CASE Drawn CkShed No. <br /> N.T.S. HILLPHONEX 05DM 48' SEE REFRIGERATION DRAWINGS X YC WCC <br /> 12'+�2'+12'+12` <br /> 3 <br /> EQUIPMENT CURB DETAIL EXHAUST CURB DETAIL NOTE: 1. GC TO INSTALL ALL EQUIPMENT IN THE LIST <br /> UNLESS NOTED OTHERWISE. Scale <br /> 3 XHAU <br /> . .s <br /> AS NOTED <br /> Date <br /> 9112121 A2n0 <br /> Project No. <br />