Laserfiche WebLink
Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />March 15, 2023 <br /> Facility Address: <br /> 6364 LINDBERGH ST, STOCKTON <br /> Facility Name: <br /> ATLANTIC AVIATION <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 719 □ V □ R □ COSFailed to locate properly or provide sufficient secondary containment for mobile/portable containersCFR 112.8(c)(11) <br /> 720 □ V □ R □ COSFailed to take corrective action on buried piping when exposed for any reasonCFR 112.8(d)(1) <br /> 721 □ V □ R □ COSFailed to provide corrosion protection for buried pipingCFR 112.8(d)(1) <br /> 722 □ V □ R □ COSFailed to cap/blank-flange connection at transfer point and mark its origin if not in serviceCFR 112.8(d)(2) <br /> 723 □ V □ R □ COSFailed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contractionCFR 112.8(d)(3) <br /> 724 □ V □ R □ COSFailed to regularly inspect aboveground valves, piping, and appurtenancesCFR 112.8(d)(4) <br /> 725 □ V □ R □ COSFailed to conduct integrity and leak testing on buried piping any time it is worked onCFR 112.8(d)(4) <br /> 726 □ V □ R □ COSFailed to adequately warn vehicles entering facility to protect piping and other transfer operationsCFR 112.8(d)(5) <br /> 727 □ V □ R □ COSPlan failed to adequately describe overfill prevention methods for each containerCFR 112.7(a)(1), <br />112.8(c)(8) <br />Other Violations <br /> 4010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br /> 4020 □ V □ R □ COSUnlisted Training violation See below <br /> 4030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br /> 4040 □ V □ R □ COSUnlisted Release/Leaks/Spills violation See below <br /> 4050 □ V □ R □ COSUnlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 203 CFR 112.3 Failure to implement the SPCC Plan. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan was not implemented, as <br />required. Per the monthly inspection requirements on page 14 of the SPCC plan, the facility is required to inspect <br />and test the overfill equipment. Per Joe, the facility has not been doing monthly testing of the overfill equipment. <br />REGULATION GUIDANCE: 112.3: The owner or operator or an onshore or offshore facility subject to this section <br />must prepare in writing and implement a Spill Prevention Control and Countermeasure Plan (hereafter “SPCC Plan” <br />or “Plan”),” in accordance with § 112.7 and any other applicable section. 25270.4.5.(a): An owner or operator shall <br />conduct periodic inspections of the storage tank to ensure compliance with Part 112 (commencing with Section <br />112.1) of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. In implementing the spill <br />prevention control and countermeasure plan, an owner or operator shall fully comply with the latest version of the <br />regulations contained in Part 112 (commencing with Section 112.1) of Subchapter D of Chapter I of Title 40 of the <br />Code of Federal Regulations. <br />CORRECTIVE ACTION: Implement the SPCC plan, as required. Submit proof of correction to the EHD. <br />This is a Class II violation. <br />FA0007770 PR0528239 SC001 03/15/2023 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 4 of 7 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD