Laserfiche WebLink
3/23/23,9:03 AM RFS Store Assessment-US <br /> Section 8: Dispenser Parts on Hand Pass Value <br /> Fail <br /> 1. Gas or Stage II Nozzle(NEPNL-0-01-2) -three on hand Pass 1.00 <br /> 2. Auto Diesel Nozzle(NEPL-0-01-2) -three on hand Pass 1.00 <br /> 3. Hi-Flow Diesel Nozzle(NM 1P-AR AD) -three on hand Pass 1.00 <br /> 4. Gas/Auto Diesel Hose(CT--3408) -three on hand Pass 1.00 <br /> 5. Diesel Hose(CT--108) -three on hand Pass 1.00 <br /> 6. Gas/Auto Diesel Breakaway(CTM75) -three of each on hand Pass 1.00 <br /> 7. Hi-Flow Diesel Breakaway(8331) -three of each on hand Pass 1.00 <br /> 8. Gas/Auto Diesel Whip Hose (CT-WHP3408) -three of each on hand Pass 1.00 <br /> 9. Hi-Flow Diesel Whip Hose (CT-WHP108) -three on hand Pass 1.00 <br /> 10.Gas/Auto Diesel Swivel (020 3/4) -three on hand Pass 1.00 <br /> 11.Hi-Flow Diesel Swivel (C720 1X1) -three on hand Pass 1.00 <br /> 12.Fuel Filters(gas, auto diesel, high flow diesel) -one case (12) of each on hand Pass 1.00 <br /> 13.DEF Nozzle(12150187N-01) - one on hand Pass 1.00 <br /> 14.DEF Hose(OPW-2IGU-1-115) - one on hand Pass 1.00 <br /> 15.DEF Breakaway(013185) - one on hand Pass 1.00 <br /> Auditor Section Comments: Section <br /> Score: <br /> 100 <br /> Section 10: Refrigeration (GL,DM) Pass Value <br /> Fail <br /> 1. Clean ice machines inlet water screens assuming easy shut off, inspect water filters check and Pass 1.00 <br /> document the water filter installed date. <br /> 2. Verify defrost heaters,time clock,defrost termination thermostat and fan delay are operational. Pass 1.00 <br /> 3. Verify condenser and evaporator fan motors are operational, and oil condenser motors, if Pass 1.00 <br /> required. <br /> 4. Verify drain heaters are operational. Pass 1.00 <br /> 5. Verify freezer door frame heaters are operational. Pass 1.00 <br /> 6. Vacuum or brush off coils and change filters on condenser coils on all undercounter/reach in Pass 1.00 <br /> units including all restaurant equipment(1/4" foam media -Grainger 6U636). <br /> 7. Clean compressor motors and fans. Pass 1.00 <br /> 8. Check for air flow blockage by product in the walk ins and refrigerators. Pass 1.00 <br /> 9. Inspect site glass for milky appearance. Pass 1.00 <br /> 10. Inspect casters for proper movement(if applicable). Pass 1.00 <br /> 11. Check that equipment is reaching desired set point using thermal gun. Pass 1.00 <br /> 12. Check suction line armaflex on remote condensers. Pass 1.00 <br /> 13. Check/Clean condensate drain lines(if applicable). Pass 1.00 <br /> 14. Validate that all thermostats are calibrated and fan switches are in the on position. Replace Pass 1.00 <br /> batteries if needed. <br /> 15. Clean all coils on coffee bar and in deli area including Cinnabon freezer drawer coils. Fail 1.00 <br /> N E <br /> Comments:Cinnabon freezer drawer is iced up. The ice doesn't allow the drawer close completely. <br /> 16. Remove any debris from the condensate pump strainer on the elliptical deli case. NA - <br /> Auditor Section Comments: Section <br /> Score: <br /> 93.3 <br /> knxgenapps01/StoreAssessment/ViewAssessment.aspx?HeaderlD=2752149 4/6 <br />