Laserfiche WebLink
nuiN 2 JAN J 0 A Q U I N Environmental Health Department <br /> P <br /> Q"= <br /> COUNTY Jasjit Kang , REHS , Director <br /> � P Muniappa Naidu, REHS , Assistant Director <br /> gCiFOR� Greatness grows here . <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Michelle Henry, REHS <br /> Elena Manzo , REHS <br /> March 28 , 2023 <br /> MERLIN BOWEN <br /> GETTLER RYAN INC <br /> 6805 SIERRA COURT SUITE G <br /> DUBLIN , CA 94568 <br /> mbowen@qrinc . com <br /> Re : ARCO 07147 Amended SR0086129 <br /> 1206 E MARCH LN <br /> STOCKTON , CA 95210 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the <br /> above- noted address . <br /> • Replaced ( 3 ) turbine sump manways lids ( Completed ) <br /> • Replaced ( 3) leak detectors ( Completed ) <br /> • Replaced (6) dispensers with conversion frames and deflector plates installation ( Completed ) <br /> • Cold start the monitoring panel ( Canceled ) <br /> • Replace the penetrations in UDCs 1 /2 , 3/4 , and 6 with split repair fittings <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust sigov . orq to arrange the following inspection appointments <br /> ( a 48- hour notice is required for inspection appointments) . <br /> a . Secondary containment testing ( 24 hydrostatic or equivalent) on UDCs 1 /2 , 3/4 , and 6 <br /> ,V Sensor functionality : Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of <br /> Regulations and the Health & Safety Code . A copy of the alarm history shall be printed <br /> prior to performing the cold start of the monitoring panel and made available at the time of <br /> EHD inspection . ( Sensor functionality testing was completed on 3/22/2023 , the cold <br /> start was not performed ) <br /> Leak detector test : Leak detector must be tested to confirm that the device can detect a <br /> leak of 3 gallons per hour at 10 psi . ( Completed ) <br /> J� Verification of the dispenser footprints contained by the under-dispenser containment <br /> sumps ( UDCs) . Any potential leaks from piping and fuel filters must drain directly into <br /> UDCs . ( Completed ) <br /> ,e' Visual inspection of the piping within the dispensers ( Completed ) <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 I F 209 464 -0138 1 www . sjgov . org/ehd <br />